background image

AM1640 Precision Industrial PRT User’s Guide

                     

 

 

Rev. 201609V3 

2/10

Before you start ---- Warnings & Cautions

 

 

 

 

 

Warnings: 

Follow these guidelines to avoid personal injury:

 

1.

 

Only use this instrument in the manufacture specified 
temperature range. 

2.

 

The handle of this instrument can become hot when it is used 
to measure high temperatures for extended periods of time. 

3.

 

DO NOT submerge PRT handle when taking measurement. 

4.

 

DO NOT use this instrument to measure the temperature of 
any hazardous live component. 

5.

 

Follow all other safety guidelines listed in this user’s guide. 
 

 

Cautions: 

Follow these guidelines to avoid possible damage to 

the instrument:

 

1.

 

Avoid mechanical shocks. DO NOT drop or slam the probe in 
any way. This will cause damage to the probe internally and 
affect its calibration and accuracy. 

2.

 

Read Section entitled “Care and Handling Guidelines” before 
removing the PRT from the shipping box. Incorrect handling 
can damage the PRT and void the warranty. 

3.

 

Keep the shipping container in case it is necessary to ship the 
PRT. Incorrect packaging of the PRT for shipment can cause 
irreparable damage. 

4.

 

Calibration Equipment should only be used by Trained 
Personnel. 
 

 

 

 
 
 

Содержание AM1640

Страница 1: ...Rev 201609V3 AM1640 Precision Industrial Platinum Resistance Thermometer User s Guide Please download the latest version at www accumac com...

Страница 2: ...librations 3 2 Specifications 4 2 1 Specifications 4 3 General Operations 5 3 1 Connecting to the readout device 5 3 2 Drive Current 5 3 3 Stability of Readings 5 3 4 Immersion Requirements 5 3 5 Ther...

Страница 3: ...live component 5 Follow all other safety guidelines listed in this user s guide Cautions Follow these guidelines to avoid possible damage to the instrument 1 Avoid mechanical shocks DO NOT drop or sla...

Страница 4: ...re temperature or change of temperature It has wide applications for dry wells or temperature baths 1 2 Main Features High accuracy 0 035 C at 0 C Temperature range 200 C to 420 C Durable and shock re...

Страница 5: ...m to maximum temperatures Hysteresis 0 01 C Self heating 50 mW C Response Time 5 seconds for 63 response to step change in water moving at 3 feet per second Measurement Current 0 5 mA or 1 mA Sensor L...

Страница 6: ...ach end of the sensor are identified by red black and white blue insulation 3 2 Drive Current AccuMac recommends 1mA as drive current to ensure the best measurement 3 3 Stability of Readings To achiev...

Страница 7: ...T has gone through an annealing process and stability test to minimize the thermal EMF which is caused by either impurities of sensing element or temperature differentials at lead wires connection poi...

Страница 8: ...ssible b When shipping the PRT use protective box and other protective packaging materials to minimize mechanical shocks as much as possible c When using dry blocks make sure the well diameter is appr...

Страница 9: ...service Be sure to have the model number and serial number of your PRT available 5 2 Problem Causes and Solutions a R0 Rtpw becomes higher significantly This is likely caused by mechanical shocks The...

Страница 10: ...ranty terms in the separate agreement shall control Each product from AccuMac Corporation is warranted to be free from defects in material and workmanship under normal use and service The warranty per...

Отзывы: