15
P
ROGRAMMING
To program the TM1A
1.
Hold the Program button for two seconds to bring the unit into Programming mode.
2.
The display will show the first parameter that can be programmed (high temperature limit). The
name of the parameter will flash, then the current value of that parameter.
3.
To change the value of a parameter, press the INCR or DECR buttons. Pressing either button
will change the parameter value by one count.
4.
Holding either button for half a second will change the parameter value by 10 counts. It will
continue to step by ten on further button pushes, as long as the pushes occur within a short
period.
5.
Releasing the INCR or DECR buttons for a half second will cause the step to revert to one.
6.
Once the unit is in Programming mode, each time the Mute button is pressed, the unit steps to
the next parameter. As the unit steps to the next parameter, the value of the previous
parameter is saved. Once the final parameter is reached, pressing the Mute button returns the
unit to Normal Run mode, saving the final parameter.