Accucold APRF11 Скачать руководство пользователя страница 5

 

LOCATION OF PARTS 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Product Features 

•  High-efficiency compressor and conversion module. 
•  CFC free and great heat insulation. 
•  DC 12/24V or AC 100~240V (using dedicated adapter) power supply. 
•  Both cooling and heating mode, cooling lowest to -20°C/-4°F, heating to +50°C/+122°F. (based 

on 25°C/77°F room temperature). 

•  Temperature memory function and three-stage intelligent battery protection system. 
•  Detailed design: convenient handle, LED display touch control panel. 

 

Technical Information 

Model 

SPRF11 & APRF11 

Rated Voltage 

DC12/24V 

or AC100-240V (using a dedicated adapter) 

Rated Power 

45W 

Capacity 

10L/0.35 cu. ft. 

Noise 

<45dB 

Temperature Setting 
Range 

Cooling: -20°C to 20°C 

H50°C 

Climate Category  

T/ST/N/SN 

Dimensions (L*W*H) 

410*355*284 (mm) 

8*14*11 3/16 (in.) 

Net Weight 

7.3 kg/16.1 lb. 

 

NOTE: 

Due to continued product improvements, the technical information may be different than your 

specific unit.  

Содержание APRF11

Страница 1: ...dels SPRF11 APRF11 User Manual BEFORE USE PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS IN THIS MANUAL Felix Storch Inc An ISO 9001 2015 registered company 770 Garrison Ave Bronx...

Страница 2: ...ion of Parts 5 Appliance Features 5 Technical Information 5 Using your Appliance 6 Cooling Heating Mode 6 Setting the Temperature 6 Battery Protection Mode 6 Voltage Reference 6 Cleaning and Care 7 Cl...

Страница 3: ...ls before operating It is recommended that a separate circuit serving only your appliance be provided Use receptacles that cannot be turned off by a switch or pull chain Never clean appliance parts wi...

Страница 4: ...the compressor 100mm Keep the equipment stable on the ground or in the car Do not drain upside down CAUTION Repairs may only be carried out by qualified personnel Incorrect repair may cause danger The...

Страница 5: ...tage intelligent battery protection system Detailed design convenient handle LED display touch control panel Technical Information Model SPRF11 APRF11 Rated Voltage DC12 24V or AC100 240V using a dedi...

Страница 6: ...temperature displayed is the current temperature of the compartment It will take several minutes to reach the set temperature NOTE If power to the unit is cut suddenly the unit will resume operation a...

Страница 7: ...nd unplug the device first to avoid electric shock 2 Take out all the items stored in the device 3 Keep the lid open 4 Wipe off the defrosted water Never use hard or pointed tools to remove ice or to...

Страница 8: ...start If the code shows again contact manufacturer for service Code F3 is displayed Possible cause the compressor starts too frequently Disconnect power to fridge for 5 minutes re start If the code sh...

Страница 9: ...9 NOTES...

Страница 10: ...accordance with electrical or plumbing codes or use of products not approved by warrantor 4 Replacement parts or repair labor costs for units operated outside the United States 5 Repairs to parts or s...

Отзывы: