equipment is only to be used with the power supply unit provided with the equipment. 

• 

Do not use electrical equipment inside the cold storage compartments of the equipment, unless they 
are of the type recommended by the manufacturer. 

• 

Once unpacked and before turning on, the equipment must be placed on a level surface for more 
than 6 hours.  

• 

Make sure that the equipment stays horizontally when it is running. The tilt angle must be less than 5° 
for long time running and be less than 45° for short time running. 

• 

Keep the ventilation openings in the unit casing or in the built-in structure free of obstacles. (Around 
the compressor≥100mm). 

• 

Keep the equipment stable on the ground or in the car; Do not drain upside down.  

 

CAUTION: Repairs may only be carried out by qualified personnel. Incorrect repair may cause danger. 

The lamp and supply cord must be replaced by the manufacturer or qualified persons. 

 

• 

Disconnect the power supply before each cleaning and maintenance and after every use. 

• 

Do not use sharp tools to defrost; Do not damage the refrigerant circuit. 

• 

heck if the cooling capacity of the equipment is suitable for storing the medicine.  

• 

If the equipment is left empty for long periods, switch off, defrost, clean, dry, and leave the door open 
to prevent mold from developing within the equipment. 

• 

The equipment is intended to be used in medical and similar applications. 

• 

Please according to local regulations 

 
 
 
 
 

- SAVE THESE INSTRUCTIONS 

– 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание APRF11

Страница 1: ...dels SPRF11 APRF11 User Manual BEFORE USE PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS IN THIS MANUAL Felix Storch Inc An ISO 9001 2015 registered company 770 Garrison Ave Bronx...

Страница 2: ...ion of Parts 5 Appliance Features 5 Technical Information 5 Using your Appliance 6 Cooling Heating Mode 6 Setting the Temperature 6 Battery Protection Mode 6 Voltage Reference 6 Cleaning and Care 7 Cl...

Страница 3: ...ls before operating It is recommended that a separate circuit serving only your appliance be provided Use receptacles that cannot be turned off by a switch or pull chain Never clean appliance parts wi...

Страница 4: ...the compressor 100mm Keep the equipment stable on the ground or in the car Do not drain upside down CAUTION Repairs may only be carried out by qualified personnel Incorrect repair may cause danger The...

Страница 5: ...tage intelligent battery protection system Detailed design convenient handle LED display touch control panel Technical Information Model SPRF11 APRF11 Rated Voltage DC12 24V or AC100 240V using a dedi...

Страница 6: ...temperature displayed is the current temperature of the compartment It will take several minutes to reach the set temperature NOTE If power to the unit is cut suddenly the unit will resume operation a...

Страница 7: ...nd unplug the device first to avoid electric shock 2 Take out all the items stored in the device 3 Keep the lid open 4 Wipe off the defrosted water Never use hard or pointed tools to remove ice or to...

Страница 8: ...start If the code shows again contact manufacturer for service Code F3 is displayed Possible cause the compressor starts too frequently Disconnect power to fridge for 5 minutes re start If the code sh...

Страница 9: ...9 NOTES...

Страница 10: ...accordance with electrical or plumbing codes or use of products not approved by warrantor 4 Replacement parts or repair labor costs for units operated outside the United States 5 Repairs to parts or s...

Отзывы: