background image

 

Warnings 

 

1) Do not attempt to service machine while running. 

 
2) Guards and doors must be in place at all times during operation. 
 

4) Do not wear loose fitting clothing or jewelry while using this machine. 
 
5) Keep hands, and arms out of the hopper (Figure 3)  and away from any 
moving parts. 

 

 

 

Figure 3 

 
6) Do not leave the machine unattended while running. 
 
7) Keep hands and face away from hose end while machine is operating. 

 
8) Only trained personnel who have read this manual should be authorized to 
operate this machine.  

  
9) Do not use objects to push material in the hopper.  
 

10) Keep cutting tools (utility knives for example) away from the hopper opening 
to avoid having these items fall into the hopper and damage the machine. 

      

 
 
 
 
 
 
 
 
 
 
 
 

 
 

Содержание 9300

Страница 1: ...Owner s Manual Accu1 Model 9300 All Fiber Insulation Blowing Machine Manufactured By Accu1Direct Inc 138 Denslow Road East Longmeadow MA 01028 T 800 438 2776 F 413 224 1294 www accu1 com...

Страница 2: ...of Operation Page 4 3 Maintenance Page 5 4 Warnings Page 7 5 Operating Instructions Page 8 6 Machine Settings Page 11 7 Airlock Seal Change Instructions Page 12 8 Troubleshooting Page 16 9 Exploded V...

Страница 3: ...cu1 reserves the right to void the warranty 5 All warranty claims must be made within the warranty period This warranty is non transferable 6 Note that the warranty does not apply if it has been deter...

Страница 4: ...into the machine hopper The agitator arms break up the compressed insulation while the auger or shredder moves the material to the air lock opening Agitator and Shredder In the airlock rotating vanes...

Страница 5: ...Maintenance Check for the following Daily 1 Clogged filters Figure 1 right Figure 1 2 Insulation build up on motors and electrical components Figure 2 5...

Страница 6: ...rlock seals Check airlock seals using a pressure gauge A minimum outlet tube pressure of 3 0 psi must be maintained for proper operation Replace when pressure drops below the minimum per the instructi...

Страница 7: ...ay from any moving parts Figure 3 6 Do not leave the machine unattended while running 7 Keep hands and face away from hose end while machine is operating 8 Only trained personnel who have read this ma...

Страница 8: ...p 120 volt grounded circuits using 10 3 AWG cords Figure 3 Note When using generators make sure they are commercial grade and and have a minimum wattage of 7500 watts Attach hardwired remote to 9300 r...

Страница 9: ...ess Start Switch Figure 5 green and release The control circuit and remote are now actuated Set remote switch to On for air material and Blower Only for just air 2 Hoses Attach 3 x 50 hose to the Airl...

Страница 10: ...top Switch red Note This switch must be pulled out for the controls to function 3 Override Switch use only when control circuit has failed Flip up protective cover Figure 5 Actuate toggle switch Red I...

Страница 11: ...t slide gate open to 3 4th hole Air Speed 6 3 0 psi minimum Hose 3 x 50 to 2 5 x50 to 2 x50 to reducer to wall tube Note All the above are suggested settings and may vary depending on operating condit...

Страница 12: ...cally because of such factors as the type and quality of the material used the more abrasive the material the shorter the life and damaging objects like knives hammers and nails Tools required pipe wr...

Страница 13: ...the square tube behind the airlock sprocket 8 Remove blower support bar and blower and set both aside 9 Use a flat screwdriver to pry the airlock off the 9300 cabinet There will be silicone caulk bead...

Страница 14: ...or and scrape silicone from airlock plate 18 Slide new felt washers onto rotor applying silicone in between last felt washer and rotor blade Rotor felt and foam washers Figure 11 19 Put the rotor back...

Страница 15: ...ls on edges Airlock housing and shredder Figure 12 28 Scrape old silicone off airlock and housing Reinstall airlock the same way as it was removed 29 Put bolts back and tighten 30 Replace blower suppo...

Страница 16: ...g 3 Blower Control dial set too low 4 Air leak into hopper blowback 5 Hose between blower and airlock damaged 1 Replace filter 2 Shorten hose length 3 Increase Blower Control setting 4 Replace airlock...

Страница 17: ...Exploded Views Parts 17...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...20...

Страница 21: ...21...

Страница 22: ...22...

Страница 23: ...23...

Страница 24: ...24...

Отзывы: