AXIOM
™
/ AXIOM-X
™
Product Line Manual
Appendices
189
A1-AXIOM-AXIOM-X_Appendices_R10.doc
Accu-Sort Systems, Inc.
TCP/IP Client
It is also possible to configure the AXIOM to operate as a TCP/IP Client. In
this case, you must also specify the IP address of the computer to which the
AXIOM is to attempt to initiate a connection. If a connection cannot be
established, the AXIOM will reattempt the connection after the specified
number of seconds (default is 5 seconds).
Similar issues exist regarding improper closing of connections as described
in the TCP/IP Server section. As a result, it is also recommended that a
heartbeat message be enabled for TCP/IP Client connections.
UDP Messaging
For UDP messaging, only the destination IP address and port need to be
specified. Since this is a connectionless means of transfer, there are no
issues with checking for loss of connection.
Содержание AXIOM
Страница 1: ...AXIOM AXIOM X Laser Bar Code Scanning Solutions Product Line Manual ...
Страница 138: ...138 Maintenance AXIOM AXIOM X Product Line Manual Accu Sort Systems Inc 07 AXIOM AXIOM X_Maintenance_R10 doc Notes ...
Страница 168: ...168 Service AXIOM AXIOM X Product Line Manual Accu Sort Systems Inc 09 AXIOM AXIOM X_Service_R10 doc Notes ...
Страница 184: ...184 Appendices AXIOM AXIOM X Product Line Manual Accu Sort Systems Inc A1 AXIOM AXIOM X_Appendices_R10 doc Notes ...
Страница 204: ...204 Appendices AXIOM AXIOM X Product Line Manual Accu Sort Systems Inc A1 AXIOM AXIOM X_Appendices_R10 doc Notes ...
Страница 210: ...210 Appendices AXIOM AXIOM X Product Line Manual Accu Sort Systems Inc A1 AXIOM AXIOM X_Appendices_R10 doc Notes ...
Страница 223: ......
Страница 224: ......
Страница 225: ......