 Model 3070AT 

Installation and Operating Instructions 

DANGER: 

DO NOT MIX CHEMICALS! 

The 

PowerBase

 3070AT chlorinator system is  

designed for use with PPG approved tablets  
only. Do not mix Cal-Hypo tablets with stabilized  
chlorine or bromine products, or other sanitizing  
chemicals. Fire or explosion could result. 

Rev 04-26-10  

NSF-50 

The PowerBase® 3070AT Chlorinator is    
NSF-Listed for pool and spa applications.  
ONLY PPG Accu-Tab® Blue SI Tablets for 
commercial pool applications are         
permitted for NSF installations. Use of 
other tablets will void NSF certification. 

Содержание PowerBase 3070AT

Страница 1: ...ets only Do not mix Cal Hypo tablets with stabilized chlorine or bromine products or other sanitizing chemicals Fire or explosion could result Rev 04 26 10 NSF 50 The PowerBase 3070AT Chlorinator is N...

Страница 2: ...or use ONLY with PPG Accu Tab Blue SI tablets utilizing the PPG patented erosion feeder technology that erodes only the bottom layer of tablets on the sieve plate while keeping tablets above the sieve...

Страница 3: ...e chlorine application point with 1 1 2 PVC pipe or hose Include an isolation valve in the line 9 Plug the power cord into an 110v receptacle 10 If a chemical controller is utilized plug the controlle...

Страница 4: ...4...

Страница 5: ...maximum inlet flow is determined 6 Adjust flow through feeder using the discharge gate valve The chlorine delivery is determined by the flow rate through the chlorinator Use the graph above to determ...

Страница 6: ...on system may develop a build up of scale This should be cleaned on a periodic basis up to twice per year If scale formation is severe more frequent cleanings may be necessary Cleaning may be accompli...

Страница 7: ...hrough the blue tubing Circulate for 10 minutes 10 Open all valves to begin purging acid from system 11 Wash the walls and sieve plate of the feeder with a hose to remove all acid residue Chlorine gas...

Страница 8: ...8 Electrical Drawing Base System...

Страница 9: ...mpers between Terminal 1 4 Terminal 2 6 Electrical Drawing With HHL Pump Switch If a chemical controller is NOT used with the HHL Pump Switch the jumpers should be placed between Terminals 1 and 4 Ter...

Страница 10: ...talled and operated and maintained in accordance with this manual and the instructions ac companying the System iii you at your cost promptly return the System or defective part to such location as ma...

Страница 11: ...11...