Gas Pressures
The appliance requires the proper gas pressure setting to operate properly. All pressure readings
should be taken after the unit has reached a temperature of at least 200°F and while it is running to
ensure proper flow rates.
Required Material: manometer, 1/8” NPT barbed hose fitting one
Tasks:
1. Verify pressure regulator vent are clear before making any pressure adjustments. Remove the
1/8” NPT pipe plug from the main gas valve and install the 1/8” NPT barbed hose fitting. Tighten
and mount one length of the rubber hose.
2. Allow the appliance to heat up to al least 200°F. First, check the main burner regulator pressure.
Remove the rubber hose and replace with the manometer tube. The pressure should be 5” WC
for natural gas and 10“WC for propane. If the pressure does not meet or exceed these values,
remove the cap on the main burner pressure regulator and adjust it to the necessary value.
3.
Replace the hose fittings with original pipe plugs.
4. Check for gas leaks.