G A M O D E L
ILLUSTRATED PARTS DRAWING –
GA MODEL
Item
No.
No. Part No.
Description
Req’d.
1
120515-01 Switch Keypad Kit ............................................................1
2
120054-01 Main Circuit Assembly ......................................................1
3
901002-82 O-Ring ..............................................................................1
4
12051701
Adapter Kit
9
125066-3
Cable, 100 ft. (Remote Model) ..........................................1
125066-20 Cable, 20 ft. (Remote Model) ............................................1
10 906005-47 Threaded Plug ..................................................................1
11 902005-9
Strain Relief ......................................................................1
12 901002-82 Seal ...................................................................................1
13 901002-87 O-Ring ..............................................................................1
15 904005-63 Screw, 4-40 x 3/16 in. .......................................................2
16 904005-28 Sealing Screw, 1/4-20 x 5/8 in. .........................................4
MAINTENANCE
All information needed for the GA Model can be found in the GX
Model sections. Consult one or all of the following:
Important Notice .....................................................................9
Safety Instructions ...................................................................9
Installation ...............................................................................9
Wiring ....................................................................................10
Wiring Diagrams ....................................................................11
Operation – 4-20 mA .............................................................14
Troubleshooting .....................................................................16
Specifications ........................................................................18
Check cable-entry seals periodically. Tighten and/or apply seal-
ant if needed. This is especially important in environments con-
taining heavy concentrations of dust, oil mist, or other residue.
Check all wiring connections occasionally for oxidation or cor-
rosion. Clean and re-seat if such conditions are noted.
If necessary, check and re-seat any connections that may have
been subjected to strain (during rework or construction, for
example).