background image

Chapter 4: Control Testing

51

:K\3HUIRUP&RQWURO7HVWV

51

$ERXWWKH&RQWURO6ROXWLRQV

52

3HUIRUPLQJD&RQWURO7HVW

53

8QGHUVWDQGLQJ2XWRI5DQJH&RQWURO7HVW5HVXOWV

57

Chapter 5: Maintenance and Troubleshooting

59

&KDQJLQJWKH%DWWHULHV

59

&OHDQLQJWKH0HWHU

61

0DLQWHQDQFHDQG7URXEOHVKRRWLQJ

62

6FUHHQ0HVVDJHVDQG7URXEOHVKRRWLQJ

63

Chapter 6: Technical Information

73

3URGXFW/LPLWDWLRQV

73

6SHFLILFDWLRQV

73

3URGXFW6DIHW\,QIRUPDWLRQ

76

'LVSRVLQJRI<RXU8VHG0HWHU

76

*XDUDQWHH

78

$GGLWLRQDO6XSSOLHV

78

,QIRUPDHDOWKFDUH3URIHVVLRQDOV

79

,QGH[

81

6

Содержание Aviva Nano

Страница 1: ...BLOOD GLUCOSE METER GLYCOM TRE User s Manual Manuel de l utilisateur ACCU CHEK Aviva Nano...

Страница 2: ...ME PLEASE TAKE THE TIME TO READ THIS MANUAL CAREFULLY BEFORE YOU USE YOUR NEW METER 4O USE IT CORRECTLY AND DEPENDABLY YOU NEED TO UNDERSTAND ITS OPERATION SCREEN DISPLAYS AND ALL INDIVIDUAL FEATURES...

Страница 3: ...sionals for monitoring patients blood glucose values The system includes some items may be sold separately Accu Chek Aviva Nano Meter with batteries Accu Chek Aviva Strips and code chip Accu Chek Aviv...

Страница 4: ...for testing fresh whole blood samples for example blood from your fingertip or forearm The meter is for outside the body in vitro use It should not be used to diagnose diabetes Only use Accu Chek Avi...

Страница 5: ...4...

Страница 6: ...PLQGHU 17 OWHUQDWH 6LWH 7HVWLQJ 67 19 8QXVXDO ORRG OXFRVH 5HVXOWV 24 6 PSWRPV RI LJK RU RZ ORRG OXFRVH 26 Chapter 3 Meter Memory Setup and Downloading 27 0HPRU 27 9LHZLQJ 7HVW 5HVXOWV 28 0HWHU 6HWXS 3...

Страница 7: ...Maintenance and Troubleshooting 59 KDQJLQJ WKH DWWHULHV 59 OHDQLQJ WKH 0HWHU 61 0DLQWHQDQFH DQG 7URXEOHVKRRWLQJ 62 6FUHHQ 0HVVDJHV DQG 7URXEOHVKRRWLQJ 63 Chapter 6 Technical Information 73 3URGXFW LPL...

Страница 8: ...s blood glucose results messages and results stored in memory Strip Slot Insert strip here Infrared IR Window Used to transfer data from the meter to a computer or PDA On Off Set Button Turns the mete...

Страница 9: ...Window Touch blood drop or control solution here 8 Strip Strip Container Control Solution Bottle On Off Set Button Top View Infrared IR Window Code Chip for example Batteries Insert into drawer with s...

Страница 10: ...hange the code chip every time you open a new box of strips 9 Coding the Meter 1 Make sure the meter is off 2 Turn the meter over 3 Remove the old code chip if there is one in the meter and discard it...

Страница 11: ...nto the code chip slot until it stops 5 Leave the code chip in the meter until you open a new box of strips Notes Do not force the code chip into the meter It is designed to go into the meter only one...

Страница 12: ...e it out of the container Be sure to check the expiry date on the strip container Do not use the strips after that date Store the strip container and meter in a cool dry place such as a bedroom Store...

Страница 13: ...12...

Страница 14: ...strip and a lancing device with a lancet loaded 1 Wash and dry your hands 2 Prepare your lancing device 3 Insert the strip into the meter in the direction of the arrows The meter turns on 4 Make sure...

Страница 15: ...our fingertip with the lancing device Blood samples taken from the palm are equivalent to blood taken from the fingertip For detailed information on how to obtain blood from the palm refer to the Alte...

Страница 16: ...to assist the flow of blood This helps you get a blood drop 8 Touch the blood drop to the front edge of the yellow window of the strip Do not put blood on top of the strip When you see flash you have...

Страница 17: ...he test result as a pre meal or post meal test or with a general marker leave the strip in the meter see the next section Otherwise remove and discard the used strip Note After a successful test the m...

Страница 18: ...ur blood glucose results to help you and your healthcare professional in the management of your diabetes When a pre meal result is marked with a post meal reminder the meter beeps one or two hours aft...

Страница 19: ...with post meal reminder that you wish to select appears on the display remove the strip from the meter If you select the post meal reminder the meter beeps one or two hours after the pre meal test to...

Страница 20: ...ttle finger hypothenar If blood from an alternate site such as the forearm upper arm thigh or calf is used there are certain times when testing is not appropriate see next page This is because your gl...

Страница 21: ...lm result still does not match how you feel talk to your healthcare professional Alternate site testing may be done Immediately before a meal Fasting DO NOT test from an alternate site Two hours or le...

Страница 22: ...the clear AST cap 1 Prepare the lancing device 2 Insert the strip into the meter in the direction of the arrows The meter turns on 3 Make sure the code number on the display matches the code number o...

Страница 23: ...rmly against a fleshy area on the alternate site Press the lancing device up and down in a slow pumping motion to assist the flow of blood 6 Trigger the lancing device while keeping steady pressure on...

Страница 24: ...ow window of the strip When you see flash you have enough blood in the strip 8 The result appears on the display Mark the result or remove and discard the used strip Note If the blood drop is too smal...

Страница 25: ...long time 4 Check if the strips were stored in a cool dry place Action Discard the strips if they are past the expiry date Replace the strips if you think they were uncapped for some time Repeat the...

Страница 26: ...unsure of the problem Action Read Chapter 2 Testing Your Blood Glucose and test again If you still have problems call Accu Chek Customer Care at 1 800 363 7949 If they do not match insert the correct...

Страница 27: ...glucose hyperglycemia fatigue increased appetite or thirst frequent urination blurred vision headache or general aching Low blood glucose hypoglycemia sweating trembling blurred vision rapid heartbeat...

Страница 28: ...helps ensure appropriate interpretation of blood glucose results by you and your healthcare professional Notes Do not change your therapy based on one individual result in memory The memory is not lo...

Страница 29: ...r product availability please contact Accu Chek Customer Care at 1 800 363 7949 28 Viewing Test Results With the meter on or off press and release or to enter memory The most recent result appears To...

Страница 30: ...l averages Post Meal Average Continue to press to view 7 14 30 and 90 day post meal averages Past Results General Average Pre Meal Average Note Only test results that have been assigned a pre meal or...

Страница 31: ...lock select On or OFF Hypo indicator select On or OFF If you select On choose the blood glucose level for the alert Using the set up mode is easy Here is a general overview of the function each button...

Страница 32: ...p symbol appears 2 Press and hold until set up appears on the display The hour flashes 3 Press and release or to decrease or increase the hour You are here TIME DATE hrs min am pm month day year BEEPE...

Страница 33: ...4 Press and release to confirm the hour The minutes flash 5 Press and release or to adjust the minutes Press and release to confirm the minutes decrease increase 32...

Страница 34: ...6 Repeat step 5 to set am pm month day and year 7 If you want to set up more options press and release If you want to exit press and hold until you see the flashing strip symbol 33...

Страница 35: ...n to the strip When enough blood or control solution is drawn into the strip When the test is complete When a button is pressed When it is time to test if you set the alarm clock or post meal reminder...

Страница 36: ...e to turn the meter on The flashing strip symbol appears 2 Press and hold until set up appears on the display 3 Press and release repeatedly until you reach the display with the flashing beeper symbol...

Страница 37: ...4 Press and release or to switch between On and OFF 5 If you want to set up more options press and release If you want to exit press and hold until you see the flashing strip symbol 36...

Страница 38: ...very two minutes up to three times Turns off by inserting a strip or pressing any button The post meal reminder time is preset on your meter to two hours however you can choose one or two hours in the...

Страница 39: ...ease to turn the meter on The flashing strip symbol appears 2 Press and hold until set up appears on the display 3 Press and release repeatedly until you reach the display with set up and the flashing...

Страница 40: ...4 Press and release or to select 1Hr or 2Hr Press and release to confirm your choice When a post meal reminder is activated this screen appears 39...

Страница 41: ...ind you to perform a test Beeps every two minutes up to three times Turns off by inserting a strip or pressing any button Is preset to OFF You must turn it on to use this feature You can set up to 4 a...

Страница 42: ...you tested within 15 minutes of an alarm the alarm does not occur If the meter is on at the alarm time the alarm does not occur Exposure to cold conditions may disable alarms until the meter is turne...

Страница 43: ...and set up remain on the display 1 Press and release to turn the meter on The flashing strip symbol appears 2 Press and hold until set up appears on the display 3 Press and release repeatedly until yo...

Страница 44: ...tch between On and OFF Press and release to confirm your choice 5 If you select On the hour flashes A 1 and the bell symbol remain on the display 6 Press and release or to select the hour Press and re...

Страница 45: ...utes Am or pm flashes on the display Press and release or to switch between am and pm Press and release to confirm am or pm 9 Set up OFF and the bell symbol appear on the display with the next alarm A...

Страница 46: ...A 4 HYPO INDICATOR off on level Setting the Hypo Indicator Function The hypo indicator Can be set to a level between 2 8 to 5 0 mmol L to let you know when your blood glucose is possibly too low Notes...

Страница 47: ...set up appears on the display 3 Press and release repeatedly until you reach the display with set up and OFF and the flashing 4 Press and release or to switch between On and OFF Press and release to...

Страница 48: ...isplay shows 3 9 mmol L 6 Press and release or to select the level you want Press and release to confirm it 7 Press and hold until you see the flashing strip symbol to exit the set up mode This functi...

Страница 49: ...ansfer the results to a computer connect the infrared cable according to the instructions 2 Run the software program and follow the instructions about how to download information Make sure the softwar...

Страница 50: ...transfer 8 Follow the prompts on the software 9 The software program may shut off the meter automatically when the data transfer is complete Notes If the data did not transfer successfully try again...

Страница 51: ...50 50...

Страница 52: ...e reliable results You should perform a control test when You open a new box of strips You left the strip container open You want to check the meter and strips Your strips were stored in extreme tempe...

Страница 53: ...you opened the control solution bottle on the bottle label The solution is good for three months from that date or until the expiry date on the bottle label whichever comes first Do not use control so...

Страница 54: ...ntrol level is printed on the bottle label 1 Insert the strip into the meter in the direction of the arrows The meter turns on 2 Make sure the code number on the display matches the code number on the...

Страница 55: ...the control solution you want to test You will enter the level later in the test 4 Put the meter on a flat surface like a table 5 Remove the control bottle cap Wipe the tip of the bottle with a tissu...

Страница 56: ...flash you have enough control solution in the strip Wipe the tip of the bottle with a tissue then cap the bottle tightly 7 The result appears on the display along with the control bottle symbol and fl...

Страница 57: ...splay if the result is in range The range is printed on the strip container label When the control result is inside the range on the strip container the strips and meter are working properly Err and t...

Страница 58: ...ip container and the control solution bottle were always closed tightly 4 Check if the strip was out of the container for a long time Action Discard the strips or control solutions if either is past t...

Страница 59: ...unsure of the problem Action Repeat the control test with a properly stored strip or control solution Read Chapter 4 Control Testing and test again If you still have problems call Accu Chek Customer...

Страница 60: ...of the meter 2 Remove the old batteries and place the new ones in the drawer with the side facing down 3 Slide the battery drawer back into position until it locks into place 59 Note When you install...

Страница 61: ...dea to have spare batteries available Be sure the batteries are inserted side facing down or facing away from you After you change the batteries the meter prompts you to confirm the meter s time and d...

Страница 62: ...the meter s surface with a soft cloth slightly dampened wring out any excess liquid with one of these cleaning solutions 70 isopropyl alcohol Mild dishwashing liquid mixed with water 10 household blea...

Страница 63: ...something is wrong If you drop the meter or think it is not giving accurate results call Accu Chek Customer Care at 1 800 363 7949 To make sure the display is working properly turn the meter off then...

Страница 64: ...u Chek Customer Care at 1 800 363 7949 The meter will not turn on or the display is blank Batteries are dead Insert new batteries Display is damaged Call Accu Chek Customer Care at 1 800 363 7949 Mete...

Страница 65: ...is low Change the batteries soon The meter is in set up mode waiting for you TO CHANGE OR CONlRM settings The meter is ready for you to insert a strip The meter is ready for a drop of blood or contro...

Страница 66: ...e higher than the measuring range of the system Blood glucose may be lower than the measuring range of the system A pre meal marker was assigned to this test result 65 A post meal marker was assigned...

Страница 67: ...the post meal reminder has been activated 66 A general marker was assigned to this test result Blood glucose is BELOW THE DElNED hypoglycemia low blood glucose level The meter is not coded or the code...

Страница 68: ...w or the strip may be damaged or not properly inserted If you see this error message after you applied blood to the strip see Chapter 2 Unusual Blood Glucose Results If you see this error message befo...

Страница 69: ...UAL LOOD LUCOSE 2ESULTS v F THIS DOES NOT CONlRM THE WAY YOU FEEL RUN A CONTROL TEST WITH YOUR CONTROL SOLUTION AND A NEW STRIP F THE CONTROL RESULT IS WITHIN THE ACCEPTABLE RANGE REVIEW THE PROPER TE...

Страница 70: ...and enter the set up mode to ensure the time and date in the meter are correct Blood or control solution was applied to the strip BEFORE THE mASHING DROP symbol appeared on the display Discard the str...

Страница 71: ...for the system Move to an area within the temperature range indicated for strip use in the strip package insert WAIT lVE MINUTES AND REPEAT THE TEST O NOT ARTIlCIALLY heat or cool the meter The batte...

Страница 72: ...Note If you see any other error screen please call Accu Chek Customer Care at 1 800 363 7949 The time and date settings may be incorrect Make sure the time and date are correct and adjust if necessar...

Страница 73: ...72...

Страница 74: ...INSERT FOR MORE INFORMATION Measuring range TO MMOL Strip storage conditions 2EFER TO YOUR STRIP PACKAGE INSERT FOR MORE INFORMATION Meter storage conditions 4EMPERATURE TO System operating condition...

Страница 75: ...2 C to 32 C Electromagnetic Compatibility This meter meets the electromagnetic immunity requirements as per ISO 15197 Annex A The chosen basis for electrostatic discharge immunity testing was basic st...

Страница 76: ...ce values are obtained using the hexokinase method For method comparison the results were compared with results obtained using the hexokinase method with deproteinization automatic analyzer The hexoki...

Страница 77: ...re present Disposing of Your Used Meter During blood glucose measurement the meter itself may come into contact with blood Used meters therefore carry a risk of infection Please dispose of your used m...

Страница 78: ...shown here with their meaning Consult the instructions for use Caution refer to accompanying documents Please refer to safety related notes in the manual accompanying this instrument Store at Manufact...

Страница 79: ...f purchase shall apply Additional Supplies The following supplies and accessories are available from your authorized Roche Diabetes Healthcare Center pharmacies or your medical surgical supply dealer...

Страница 80: ...cisions about whether to recommend alternate site testing AST should take into account the motivation and knowledge level of the patient and his or her ability to understand the considerations relativ...

Страница 81: ...e physical condition Our studies involving alternate site testing of adults with diabetes show that most persons will lND their glucose level changes more quickly in the lNGERS PALMS blood THAN THE AL...

Страница 82: ...to 48 control solution 52 control test results understanding 57 control test acceptable range 56 control test performing 53 control test results 57 control test unacceptable range 57 display check 62...

Страница 83: ...marker 17 18 28 30 product limitations 73 product specifications 73 rapid heartbeat 26 settings meter 30 supplies 78 sweating 26 symbols 77 technical information 73 strips Accu Chek Aviva 8 11 thirst...

Страница 84: ...de chip and strips is covered by the following patents Canadian Patent Nos 2 068 214 2 153 877 2 153 883 2 153 884 2 175 501 Le syst me Accu Chek Aviva Nano comprenant le glycom tre la puce d talonnag...

Страница 85: ...Accu Chek AVIVA NANO are trademarks of Roche All other product names and trademarks are the property of their respective owners Accu Chek Accu Chek AVIVA et Accu Chek AVIVA NANO sont des marques de Ro...