VDSL Configuration
3-63
CLI
–The following examples show how VDSL link current values are displayed in
the CLI.
Examples
The following example displays VDSL link current values on VDSL switch port 2.
The following example displays link status, signal-to-noise ratios, Reed-Solomon
errors, interleaver parameters and PBO status on VDSL switch port 1.
This command displays the downstream and upstream rates of the VDSL port 1.
Console#show controller efm Ethernet 1/2 actual dsrserrs
4-111
Downstream Reed-Solomon errors: 0
Console#show controller efm Ethernet 1/2 actual link
Link status: Down
Console#show controller efm Ethernet 1/2 actual rxpower
Local receive power: 26.00 dBm/Hz
Console#show controller lre Ethernet 1/2 actual snr
SNR: 27.00 dB
Console#show controller efm Ethernet 1/2 actual txpower
Remote transmit power: -89.70 dBm/Hz
Console#
Console#show controllers efm status link Ethernet 1/1
4-114
Interface Link SNR (dB) RS Errs Interleaver
DS1 DS2 US1 US2 DS.M DS.I US.M US.I PBO
------------- ---- -------------------- -------- ------------------- ---
Ethernet 1/1 Up 43.0 35.0 45.0 43.0 0 16 8 8 8 on
Console#
Console#show controller efm Ethernet 1/1 admin usrate
4-112
Upstream rate: 12.50 Mbps
Console#show controller efm Ethernet 1/1 admin dsrate
Downstream rate: 12.50 Mbps
Console#
Содержание VDSL Switch-VS4512
Страница 1: ...VDSL Switch VS4512 VDSL Switch VS4512DC Management Guide...
Страница 2: ......
Страница 22: ...Introduction 1 8...
Страница 100: ...Configuring the Switch 3 70 Web Click VDSL Performance Monitor Information...
Страница 146: ...Configuring the Switch 3 116...
Страница 320: ...A 4 Software Specifications...
Страница 322: ...B 2 Troubleshooting...
Страница 332: ...Index Index 4...
Страница 333: ......
Страница 334: ...VS4512 VS4512DC E122003 R02 150000041800A...