background image

Introduction

1-1

Chapter 1:  Introduction

  Switching Technology

The Ethernet Switch allows simultaneous transmission of multiple packets via
an internal high-speed data channel.  This means that it can partition a network
more efficiently than bridges or routers.  The Ethernet Switch is therefore fast
being recognized as one of the most important building blocks for today’s
networking technology.

The learning function in the switch stores the address and corresponding port
number of each incoming and outgoing packet in a routing table.  This
information is subsequently used to filter packets whose destination address is
on the same segment as the source address.  This confines network traffic to its
respective domain, reducing the overall load on the network.

The switch scans the destination address from the packet header, searches the
routing table provided for the incoming port and forwards the packet only if
required, often before fully received.  This fast forwarding makes the switch
attractive for connecting servers directly to the network, thereby increasing
throughput and availability.  However, the switch is most commonly used to
segment existing hubs, which nearly always improves overall performance.  A
switch can be easily configured in any Ethernet network to significantly boost
bandwidth using conventional cabling and adapters.

Содержание SwitcHub-2se

Страница 1: ...SwitcHub 2se INO GG ODJI IP G...

Страница 2: ...Installation Manual SwitcHub 2se Smart Fast Ethernet Switch with one 10BASE T 100BASE TX Port and one 100BASE FX Port...

Страница 3: ...o make revisions to this publication without obligation to notify any person or entity of any such changes QWHUQDWLRQDO HDGTXDUWHUV No 1 Creation Road III Science based Industrial Park Hsinchu 300 Tai...

Страница 4: ...lation manual Owner registration card Please inform your dealer immediately should there be any wrong missing or damaged parts If possible retain the carton including the original packing materials Us...

Страница 5: ...another switch or other network interconnection device by running straight through twisted pair cable between the MDI daisy chain port on one device e g Port 1 on this switch to the MDI X station por...

Страница 6: ...unications by ensuring that you have made all the necessary connections you can access any connected resources the switch s indicator LEDs are functioning properly Note For devices connected directly...

Страница 7: ...s manual covers the following topics Chapter 1 Product Overview Brief description of switching technology followed by a description of this switch and a summary of its important features and specifica...

Страница 8: ...ystem 2 1 Making RJ 45 Connections 2 2 Making Fiber Optic Connections 2 3 Providing Power to the SwitcHub 2 4 Diagnostic Tests 2 5 Upon Power On 2 5 During Normal Operation 2 5 Setting the Display Mod...

Страница 9: ...3 4 Setting the Communication Mode 3 6 Diagnostics Display Mode 3 7 Port Status Display 3 8 Rear Panel 3 10 Ethernet Ports 3 10 Power Socket 3 11 Appendix A Troubleshooting A 1 Diagnosing Hub Indicato...

Страница 10: ...e D 4 Underwriters Laboratories Compliance Statement D 4 Sicherheitshinweise D 5 Appendix E Product Support Services E 1 Product Registration E 1 Problem Report E 1 Hardware Repair Service E 1 Softwar...

Страница 11: ...ed to filter packets whose destination address is on the same segment as the source address This confines network traffic to its respective domain reducing the overall load on the network The switch s...

Страница 12: ...on between networks based on twisted pair and fiber optic cabling and can also be configured to operate in either full duplex or half duplex data transfer mode to support the interconnection requireme...

Страница 13: ...devices Compared to this safe mode of operation cut through reduces the packet transmission delay to around 20 microseconds by picking the destination address out of the header as soon as its received...

Страница 14: ...s and 1 MDI X port for connection to workstations or servers eliminating the need for crossover cables Provides one independent 100BASE FX port with Rx Tx jacks SC or ST type connectors can be used de...

Страница 15: ...collision domain i e a half duplex connection Provides frame filtering and forwarding functions for each port which are capable of filtering and forwarding 100 of all Ethernet packets at line speed Pr...

Страница 16: ...for ventilation Check if network cables and connectors needed for installation are available Find a suitable location at the center of the devices you want to link and near a power outlet Connecting t...

Страница 17: ...rk interconnection device attach one end of the cable to the MDI crossover port on the switch and the other end to an MDI X station port on the other device or vice versa When cascading to devices oth...

Страница 18: ...ber optic cabling the maximum length between two switches can be up to 2 kilometers However you must consider power loss when calculating the actual length of cable that can be used with your system Y...

Страница 19: ...hen the 100BASE FX link is used for a dedicated connection i e full duplex communications cable length should not exceed 2 kilometers However when the link is used for a shared collision domain i e ha...

Страница 20: ...this test takes about 50 seconds to complete For details about the system self diagnostic test refer to the following section Diagnostic Tests Upon Power On Upon power on the system performs an inter...

Страница 21: ...ts transmitted by the port Full Half Duplex Sets port communication mode to full duplex or half duplex operation Diagnostics Tests the status of various system components A long press on the Configure...

Страница 22: ...to available bandwidth Packet Forwarding Ratio Active LED Forward ON In this mode the statistical indicators show the percentage of packets that must be forwarded by bridging hardware to the other por...

Страница 23: ...ill be lit After the Configure button is released the Full LED for Port 1 will begin to flash 2 To change the current setting for a port use a short press i e light the Full LED to select full duplex...

Страница 24: ...fficulties in setting up the switch refer to Appendix A Verifying System Operation Verify that all attached devices have a valid connection The switch monitors link status for each port If any device...

Страница 25: ...length of fiber optic cable does not exceed 2 kilometers for a dedicated link or 412 meters when used in a shared collision domain Be sure to consider signal attenuation when determining the maximum l...

Страница 26: ...irements for Ethernet and IEEE 802 3 networks This chapter describes the hardware features of the Fast SwitcHub 2se For easier management and control of the switch familiarize yourself with the displa...

Страница 27: ...on the Configure button The indicators will light up to show the selected configuration function Refer to the related sections in this chapter and to Chapter 2 for complete details 2 To scan through...

Страница 28: ...s the status of port connections and 5 shows the result of diagnostic tests The following figure shows the LED indicators each of which are described in the following sections Power Display Mode Perfo...

Страница 29: ...rcentage 70 Orange of LAN bandwidth 50 Orange Forward Display Mode The percentage of packets 35 Green that are forwarded to another port 20 Green Filter Display Mode The percentage of packets 10 Green...

Страница 30: ...Display Mode Filter The statistical indicators show the percentage of packets that must be filtered from the switch by hardware because the destination address is on the same segment connected to the...

Страница 31: ...can be set to either full duplex or half duplex operation Use the Configure button to light the Full Half Display Mode LED indicating that the transmission mode may now be set for the ports Next set...

Страница 32: ...m is detected the current diagnostic process i e system or port test will continue until completed If the test is not completed successfully the corresponding LEDs described below will flash after tes...

Страница 33: ...Port 2 statistcs are displayed on the bottom row Status Link Status Link Indicates a valid network connection associated with the port LED Activity Condition Indication STEADY LIGHT ON Indicates a val...

Страница 34: ...n for the indicated port LED Activity Condition Indication STEADY LIGHT ON Port is set for full duplex operation NO LIGHT OFF Port is set for half duplex operation Note Full duplex operation only appl...

Страница 35: ...ts one is used for 100BASE TX or 10BASE T media and the other for 100BASE FX media 100BASE TX or 10BASE T The STP RJ 45 port pair provides one MDI X port for connecting to a workstation or server and...

Страница 36: ...c cable can be used for making connections to both 10 Mbps and 100 Mbps Ethernet Therefore when upgrading older fiber optic Ethernet to the newer Fast Ethernet check to see if you actually need to cha...

Страница 37: ...rt is defective Solution The most common cause for a bad connection to a workstation or server is a defective network adapter or cable connection Check the workstation s network adapter and cable conn...

Страница 38: ...fer to Setting the Communica tion Mode in Chapter 3 for a detailed description Cabling 1 Verify that the cabling type is correct Be sure all cable connectors are securely seated in the required ports...

Страница 39: ...hanges one step at a time Ensure that cable distances and other physical aspects of the installation do not exceed recommendations Switch Integrity As a last resort verify the switch s integrity with...

Страница 40: ...smit Data 2 Input Receive Data Output Transmit Data 3 Output Transmit Data Input Receive Data 6 Output Transmit Data Input Receive Data 4 5 7 8 Not Used Not Used Table B 1 RJ 45 Pin Assignments Schema...

Страница 41: ...TX or 10BASE T via auto detection 1 fiber optic port with SC or ST type jacks Dimensions 273mm x 166mm x 42 9mm 10 75 x 6 54 x 1 69 Power Requirements Full range power input 100 to 240V 50 60 Hz 27 wa...

Страница 42: ...equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there i...

Страница 43: ...oklet prepared by the Federal Communications Commission helpful The Interference Handbook This booklet is available from the U S Government Printing Office Washington D C 20402 Stock No 004 000 00345...

Страница 44: ...is to certify that this product complies with ISO IEC Guide 22 and EN45014 It conforms to the following specifications EMC EN55022 1988 CISPR 22 1985 class B EN60555 2 1987 class A EN60555 3 prEN5502...

Страница 45: ...um length of 15 feet Parallel blade grounding type attachment plug rated 15A 125V 240 Volts For North America UL Listed CSA Certified Cord Set Minimum 18 AWG Type SVT or SJT three conductor cord Maxim...

Страница 46: ...ng des Ger tes durch berhitzung kommen 6 Versuchen Sie niemals dieses Ger t selbst zu warten da beim ffnen oder Abnehmen des Geh uses die Gefahr eines elektrischen Schlages besteht 7 Keine Gegenst nde...

Страница 47: ...occurred when they occurred duration of the problems the unit number serial number hardware software and the DOS version that you are using Then contact your dealer or Accton Technology Corporation fo...

Страница 48: ...upgrade services at a specially reduced price Bulletin Board Service BBS In countries other than the U S call 886 35 770 654 to reach Accton Taiwan s modem line Modems with 14400 through 2400 baud ar...

Страница 49: ...connect via ftp to ftp accton com tw Send your technical questions by email to support accton com tw Mail your technical questions to International Headquarters Accton Technology Corporation Attn Tech...

Страница 50: ...CULAR PURPOSE OR ANY WARRANTY ARISING OUT OF ANY PROPOSAL SPECIFICATION OR SAMPLE ACCTON SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ACCTON NEITHER ASSUMES NOR AUTHORIZES ANY PERSON TO...

Страница 51: ...OR SPECIAL DAMAGES CAUSED BY THE USE OF THIS PRODUCT OR INABILITY TO USE IT EVEN IF THE COMPANY OR ACCTON HAS BEEN ADVISED OF SUCH LIABILITY OR OTHER SPECIAL CLAIMS If you purchased this product in t...

Страница 52: ...T FAX 408 452 8811 Accton UK The Mill Horton Road Stanwell Moor Staines Middx TW19 6BJ United Kingdom Phone 44 1753 687677 44 1753 680109 Fax 44 1753 689010 Accton Australia Unit 23 No 27 Doomben Ave...

Страница 53: ...Ethernet using multimode fiber optic cable The maximum length of cable for a point to point connection is 2 kilometers for a dedicated link i e full duplex connection or 412 meters for a shared colli...

Страница 54: ...fiber optics broadband and twisted pair IEEE 802 3 Standard Standard for the physical and electrical connections in local area networks developed by the IEEE The IEEE 802 3u standard covers these same...

Страница 55: ...J 45 Connector Most common terminator for twisted pair wiring Shielded Twisted Pair STP Twisted pair wire covered with an external aluminum foil or woven copper shield designed to reduce excessive noi...

Страница 56: ...witcHub 2se 1 2 Filter Packets 1 1 Forward Packets 1 1 Front Panel 3 1 Full Half Duplex Mode Selection 2 7 H Hardware Reference 3 1 I Installation Requirements 2 1 L LED Indicators 100 3 9 Coll 3 5 Di...

Страница 57: ...ering Information E 6 Software Update and Upgrade Service E 2 Technical Support E 3 Providing Power to the SwitcHub 2 4 R Rear Panel 3 10 RJ 45 Port MDI 2 2 MDI X 2 2 S Safety Compliance D 4 Setup and...

Страница 58: ...ES3002 TF E0596 R01 150050 101...

Отзывы: