background image

1

Introduction

The CheetahSwitch Workgroup-3726M is perfect for moving workgroups from 
conventional 10 Mbps Ethernet to multiple-segment 100 Mbps Fast Ethernet, and 
for consolidating your network equipment into a single, clean, efficient, and 
super-fast switch stack. This switch system delivers dedicated 100 Mbps links to 
each attached LAN segment (independent collision domain) or to any PC attached 
directly to the stack – all with conventional cabling and adapters. It completely 
eliminates the bottlenecks of shared 10 Mbps Ethernet networks by providing a wide 
bandwidth of up to 8.8 Gbps per switch, and a stack backplane that can operate at 
up to 9.6 Gbps. This makes it ideal for increasing the throughput of interconnected 
Ethernet and Fast Ethernet hubs or server farms.

This switch includes three slots on the rear panel for various modules:
• The upper slot is for an SNMP/RMON Management Module. The stack supports only 

one management agent.

• The lower right slot is for optional media expansion modules, including a dual-port 

100 Mbps fiber optic module that can be connected to a remote site up to 
2 kilometers (1.24 miles) away, or a single-port Gigabit module that can be used to 
uplink to a collapsed Gigabit backbone or for a high-speed server connection. 

• The lower left slot is for either an optional media expansion module or Stacking 

Module. (Up to four switch units can be stacked together using Stacking Modules.)

When the Management Module is installed, this system can provide a wide array of 
advanced features:
• Master agent module manages entire stack in-band or out-of-band
• Backup agent module provides fault tolerance*
• Supports Telnet, SNMP/RMON and Web-based interface
• Four-group RMON (including Statistics, History, Alarms and Events)
• Spanning Tree Algorithm for redundant paths between switches
• VLAN support for up to 256 groups, port-based or with 802.1Q VLAN tagging
• GVRP for automatic VLAN learning*
• IGMP multicast filtering 
• Quality of Service supports two levels of priority with Weighted Fair Queueing
• Configurable broadcast storm control
• Port mirroring (for real-time debugging without affecting the target port)
• Port trunking (up to 5 trunks per switch or 12 trunks for the entire stack, each trunk 

contains 2~4 ports)

* This feature is not supported in the current firmware release.

The agent module allows you to configure or monitor the switch using the embedded 
management program or SNMP/RMON applications. To manage the switch, you can 
make a direct connection to the console port. You can also make a network 
connection to manage the switch using Telnet, the Web agent, or Accton’s free 
Windows-based network management software called AccView/Open. 

Содержание CheetahSwitch Workgroup-3726M

Страница 1: ...CheetahSwitch Workgroup 3726M Quick Installation Guide...

Страница 2: ......

Страница 3: ...Quick Installation Guide CheetahSwitch Workgroup 3726M Intelligent Stackable Fast Ethernet Switch with 24 10BASE T 100BASE TX RJ 45 Ports and Optional Media Expansion and Stack Modules...

Страница 4: ...Irvine CA 92618 Phone Numbers Sales 800 926 9288 Support 888 398 4101 or 949 707 4847 RMA 800 762 4968 Fax 949 707 2460 Copyright 2002 by Accton Technology Corporation All rights reserved No part of t...

Страница 5: ...n product A list of discontinued products is attached with the firmware configuration information or memory data of Customer contained in stored on or integrated with any products returned to Accton p...

Страница 6: ...OR IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE USE PERFORMANCE FAILURE OR INTERRUPTION OF ITS PRODUCTS EVEN IF ACCTON OR ITS AUTHORIZED RESELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DA...

Страница 7: ...ort 7 Powering On the Switch 8 Verifying Port Status 9 Verifying System Operation 9 Applications 10 Product Specifications 11 Base Unit 11 Physical Characteristics 11 Switching Criteria 12 Traffic Con...

Страница 8: ...on of Conformance for EMI and Safety EEC 17 Safety Compliance 18 Warning Fiber Optic Port Safety 18 Avertissment Ports pour fibres optiques s curit sur le plan optique 18 Warnhinweis Faseroptikanschl...

Страница 9: ...high speed server connection The lower left slot is for either an optional media expansion module or Stacking Module Up to four switch units can be stacked together using Stacking Modules When the Ma...

Страница 10: ...dule while the lower right slot can be used for a media expansion module Note that the media expansion modules include a Fast Ethernet fiber optic module with two 100BASE FX SC type ports or a one por...

Страница 11: ...ce If you intend to mount the switch in a rack make sure you have all the necessary mounting screws brackets bolts and nuts and the right tools Check if network cables and connectors needed for instal...

Страница 12: ...upper slot by removing the two screws with a flat head screwdriver 3 Before opening the package that contains the module touch the bag to the switch casing to discharge any potential static electrici...

Страница 13: ...he slot along the guide rails ensuring that it firmly engages with the connector 6 If you are sure the module is properly mated with the connector tighten the retainer screws to secure the module in t...

Страница 14: ...r standard 10 Mbps Ethernet connections or 100 ohm Category 5 cable for 100 Mbps Fast Ethernet connections 3 Connect one end of the cable to the RJ 45 port of the network interface card and the other...

Страница 15: ...ort When connecting fiber cable to a Gigabit fiber optic port on the switch be sure you use an SC type connector Follow the steps below Warning This switch uses lasers to transmit signals over fiber o...

Страница 16: ...to any input voltage within the range marked on the rear panel 3 The switch performs a self diagnostic test upon power on Note that this test takes several minutes to complete Note The unit supports a...

Страница 17: ...tus LEDs on the switch panel should be on indicating that the modules are installed and operating correctly Verify that all attached devices have a valid connection The switch monitors the link status...

Страница 18: ...Functions This switch provides fully transparent bridging functions It automatically learns node addresses that are subsequently used to filter and forward all traffic based on the destination address...

Страница 19: ...24 RJ 45 100BASE TX ports Indicator Panel System Power RDP Mgmt Ports link speed disabled partitioned activity duplex flow control Dimensions 440 x 285 x 64 mm 17 37 x 11 22 x 2 53 in Weight 4 5 kg 9...

Страница 20: ...old Modules Management Module AC ES3726M AGENT System Configuration Configuration via console connection to serial port or via Telnet Web based management via HTTP protocol to access embedded manageme...

Страница 21: ...nformance IEEE 802 3z Communication Rate 1000 Mbps Communication Mode Full or half duplex Output Power Minimum 9 5 dBm Maximum 3 dBm Receiver Sensitivity Minimum 20 dBm Saturation 3 dBm Power Budget 1...

Страница 22: ...switch port may be defective Verify that the switch and attached device are powered on Be sure the cable is plugged into both the switch and corresponding device Verify that the proper cable type is u...

Страница 23: ...ters 328 feet Straight Through Wiring If the twisted pair cable is to join two ports and only one of the ports has an internal crossover MDI X the two pairs of wires must be straight through Crossover...

Страница 24: ...d to take whatever measures are required to correct the interference You may use unshielded twisted pair UTP for RJ 45 connections Category 3 or greater for 10Mbps connections and Category 5 for 100Mb...

Страница 25: ...nd flicker in low voltage supply system according to EN 61000 3 3 1995 Immunity Product family standard according to EN 55024 1998 Electrostatic Discharge according to EN 61000 4 2 1995 Contact Discha...

Страница 26: ...sse Optische Sicherheit Niemals ein bertragungslaser betrachten w hrend dieses eingeschaltet ist Niemals direkt auf den Faser TX Anschlu und auf die Faserkabelenden schauen w hrend diese eingeschalte...

Страница 27: ...Zeitraum nicht benutzt sollten Sie es vom Stromnetz trennen Somit wird im Falle einer berspannung eine Besch digung vermieden 12 Durch die L ftungs ffnungen d rfen niemals Gegenst nde oder Fl ssigkeit...

Страница 28: ...Module with 2 100BASE FX SC type Ports EM4582 SX SC Media Module with 1 1000BASE SX SC type Port EM4582 LX SC Media Module with 1 1000BASE LX SC type Port EM3580 STACK Stacking Module kit including 30...

Страница 29: ......

Страница 30: ...AC ES3726M E012002 R01 F2 476 150200008100A...

Отзывы: