background image

Quick Installation Guide

2

Installing the Switch

Before installing the switch verify that you have all the items listed under “Package 
Contents.” If any of the items are missing or damaged, contact your local Accton 
distributor. Also be sure you have all the necessary tools and cabling before 
installing the switch. Note that this switch can be installed on any suitably large flat 
surface or in a standard EIA 19-inch rack. After installing the switch, refer to the 
Management Guide to set up its more advanced features, such as Spanning Tree 
Protocol or VLAN port groups.

Package Contents

This package includes:

Description of Hardware

The base unit contains 24 10BASE-T/100BASE-TX ports, plus three slots on the 
rear panel for various modules. A Management Module can be installed in the upper 
slot on the rear panel (see “Installing a Management Module” on page 4). The 
lower-left slot can be used for an optional media expansion module or Stacking 
Module, while the lower-right slot can be used for a media expansion module. Note 
that the media expansion modules include a Fast Ethernet fiber optic module with 
two 100BASE-FX (SC type) ports or a one port Gigabit 1000BASE-SX (SC type), or 
1000BASE-LX uplink module. 

All RJ-45 ports on the base unit operate at 10 or 100 Mbps, and support 
auto-negotiation of speed, duplex mode (i.e., half or full duplex), and flow control.

The 1000BASE-SX and 1000BASE-LX  ports are fixed at 1000 Mbps but 
auto-negotiate duplex mode. The 100BASE-FX module is fixed at the 100 Mbps, full 
duplex. All media types can auto-negotiate flow control.

Note that when using auto-negotiation, the speed, transmission mode and flow 
control can be automatically set if this feature is also supported by the attached 
device. Otherwise, these items can be manually configured for any connection. 

The base unit also includes a display panel for key system and port indications that 
simplify installation and network troubleshooting.

• CheetahSwitch Workgroup-3726M (Model No. AC-ES3726M)
• Four rubber foot pads

• This Quick Installation Guide

• Rack mount bracket kit

• Owner registration card

• AC power cord

Содержание CheetahSwitch Workgroup-3726M

Страница 1: ...CheetahSwitch Workgroup 3726M Quick Installation Guide...

Страница 2: ......

Страница 3: ...Quick Installation Guide CheetahSwitch Workgroup 3726M Intelligent Stackable Fast Ethernet Switch with 24 10BASE T 100BASE TX RJ 45 Ports and Optional Media Expansion and Stack Modules...

Страница 4: ...Irvine CA 92618 Phone Numbers Sales 800 926 9288 Support 888 398 4101 or 949 707 4847 RMA 800 762 4968 Fax 949 707 2460 Copyright 2002 by Accton Technology Corporation All rights reserved No part of t...

Страница 5: ...n product A list of discontinued products is attached with the firmware configuration information or memory data of Customer contained in stored on or integrated with any products returned to Accton p...

Страница 6: ...OR IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE USE PERFORMANCE FAILURE OR INTERRUPTION OF ITS PRODUCTS EVEN IF ACCTON OR ITS AUTHORIZED RESELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DA...

Страница 7: ...ort 7 Powering On the Switch 8 Verifying Port Status 9 Verifying System Operation 9 Applications 10 Product Specifications 11 Base Unit 11 Physical Characteristics 11 Switching Criteria 12 Traffic Con...

Страница 8: ...on of Conformance for EMI and Safety EEC 17 Safety Compliance 18 Warning Fiber Optic Port Safety 18 Avertissment Ports pour fibres optiques s curit sur le plan optique 18 Warnhinweis Faseroptikanschl...

Страница 9: ...high speed server connection The lower left slot is for either an optional media expansion module or Stacking Module Up to four switch units can be stacked together using Stacking Modules When the Ma...

Страница 10: ...dule while the lower right slot can be used for a media expansion module Note that the media expansion modules include a Fast Ethernet fiber optic module with two 100BASE FX SC type ports or a one por...

Страница 11: ...ce If you intend to mount the switch in a rack make sure you have all the necessary mounting screws brackets bolts and nuts and the right tools Check if network cables and connectors needed for instal...

Страница 12: ...upper slot by removing the two screws with a flat head screwdriver 3 Before opening the package that contains the module touch the bag to the switch casing to discharge any potential static electrici...

Страница 13: ...he slot along the guide rails ensuring that it firmly engages with the connector 6 If you are sure the module is properly mated with the connector tighten the retainer screws to secure the module in t...

Страница 14: ...r standard 10 Mbps Ethernet connections or 100 ohm Category 5 cable for 100 Mbps Fast Ethernet connections 3 Connect one end of the cable to the RJ 45 port of the network interface card and the other...

Страница 15: ...ort When connecting fiber cable to a Gigabit fiber optic port on the switch be sure you use an SC type connector Follow the steps below Warning This switch uses lasers to transmit signals over fiber o...

Страница 16: ...to any input voltage within the range marked on the rear panel 3 The switch performs a self diagnostic test upon power on Note that this test takes several minutes to complete Note The unit supports a...

Страница 17: ...tus LEDs on the switch panel should be on indicating that the modules are installed and operating correctly Verify that all attached devices have a valid connection The switch monitors the link status...

Страница 18: ...Functions This switch provides fully transparent bridging functions It automatically learns node addresses that are subsequently used to filter and forward all traffic based on the destination address...

Страница 19: ...24 RJ 45 100BASE TX ports Indicator Panel System Power RDP Mgmt Ports link speed disabled partitioned activity duplex flow control Dimensions 440 x 285 x 64 mm 17 37 x 11 22 x 2 53 in Weight 4 5 kg 9...

Страница 20: ...old Modules Management Module AC ES3726M AGENT System Configuration Configuration via console connection to serial port or via Telnet Web based management via HTTP protocol to access embedded manageme...

Страница 21: ...nformance IEEE 802 3z Communication Rate 1000 Mbps Communication Mode Full or half duplex Output Power Minimum 9 5 dBm Maximum 3 dBm Receiver Sensitivity Minimum 20 dBm Saturation 3 dBm Power Budget 1...

Страница 22: ...switch port may be defective Verify that the switch and attached device are powered on Be sure the cable is plugged into both the switch and corresponding device Verify that the proper cable type is u...

Страница 23: ...ters 328 feet Straight Through Wiring If the twisted pair cable is to join two ports and only one of the ports has an internal crossover MDI X the two pairs of wires must be straight through Crossover...

Страница 24: ...d to take whatever measures are required to correct the interference You may use unshielded twisted pair UTP for RJ 45 connections Category 3 or greater for 10Mbps connections and Category 5 for 100Mb...

Страница 25: ...nd flicker in low voltage supply system according to EN 61000 3 3 1995 Immunity Product family standard according to EN 55024 1998 Electrostatic Discharge according to EN 61000 4 2 1995 Contact Discha...

Страница 26: ...sse Optische Sicherheit Niemals ein bertragungslaser betrachten w hrend dieses eingeschaltet ist Niemals direkt auf den Faser TX Anschlu und auf die Faserkabelenden schauen w hrend diese eingeschalte...

Страница 27: ...Zeitraum nicht benutzt sollten Sie es vom Stromnetz trennen Somit wird im Falle einer berspannung eine Besch digung vermieden 12 Durch die L ftungs ffnungen d rfen niemals Gegenst nde oder Fl ssigkeit...

Страница 28: ...Module with 2 100BASE FX SC type Ports EM4582 SX SC Media Module with 1 1000BASE SX SC type Port EM4582 LX SC Media Module with 1 1000BASE LX SC type Port EM3580 STACK Stacking Module kit including 30...

Страница 29: ......

Страница 30: ...AC ES3726M E012002 R01 F2 476 150200008100A...

Отзывы: