background image

Quick Installation Guide

4

Mounting Switches in a Rack

Please comply with the following instructions to ensure that your switch is securely 
mounted in the rack.

1.

Use a standard EIA 19-inch rack. 

2.

Use the brackets and screws supplied in 
the rack mounting kit.

3.

Use a cross-head screwdriver to attach the 
brackets to the side of the switch.

4.

Position the switch in the rack by lining up 
the holes in the attached brackets with the 
appropriate holes on the rack, and then 
use the rack-mount screws to mount the 
switch in the rack.

Installing a Management Module

One Management Module is required to manage all of the switches in the stack. A 
Management Module only installs in a switch’s rear-panel upper slot, do not try to 
install it in either of the two lower slots.

You can install a Management Module as described below:

1.

Disconnect power to the switch (the modules are 

not

 hot-swappable).

2.

Remove the face plate on the switch’s upper slot by removing the two screws 
with a flat-head screwdriver. 

3.

Before opening the package that contains the module, touch the bag to the 
switch casing to discharge any potential static electricity.

4.

Remove the module from the anti-static shielded bag.

5.

Holding the module level, gently push it all the way into the slot along the guide 
rails, ensuring that it firmly engages with the connector.

6.

If you are sure the module is properly mated with the connector, tighten the 
retainer screws to secure the module in the slot.

Caution:

The slide-in modules are 

not

 hot-swappable. Be sure you power off the switch 

before installing any of these modules.

Installing Optional Media and Stacking Modules

The two lower slots on the rear panel of the switch are provided for various optional 
media expansion modules (100BASE-FX or Gigabit) or Stacking Modules. The 
100BASE-FX fiber optic module can be used to connect to remote sites, and a 
Gigabit module can be used as a network backbone. You can install the media 
expansion modules in either of the two lower slots, but the Stacking Module must 
only be installed in the lower-left slot.

1

Содержание CheetahSwitch Workgroup-3726M

Страница 1: ...CheetahSwitch Workgroup 3726M Quick Installation Guide...

Страница 2: ......

Страница 3: ...Quick Installation Guide CheetahSwitch Workgroup 3726M Intelligent Stackable Fast Ethernet Switch with 24 10BASE T 100BASE TX RJ 45 Ports and Optional Media Expansion and Stack Modules...

Страница 4: ...Irvine CA 92618 Phone Numbers Sales 800 926 9288 Support 888 398 4101 or 949 707 4847 RMA 800 762 4968 Fax 949 707 2460 Copyright 2002 by Accton Technology Corporation All rights reserved No part of t...

Страница 5: ...n product A list of discontinued products is attached with the firmware configuration information or memory data of Customer contained in stored on or integrated with any products returned to Accton p...

Страница 6: ...OR IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE USE PERFORMANCE FAILURE OR INTERRUPTION OF ITS PRODUCTS EVEN IF ACCTON OR ITS AUTHORIZED RESELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DA...

Страница 7: ...ort 7 Powering On the Switch 8 Verifying Port Status 9 Verifying System Operation 9 Applications 10 Product Specifications 11 Base Unit 11 Physical Characteristics 11 Switching Criteria 12 Traffic Con...

Страница 8: ...on of Conformance for EMI and Safety EEC 17 Safety Compliance 18 Warning Fiber Optic Port Safety 18 Avertissment Ports pour fibres optiques s curit sur le plan optique 18 Warnhinweis Faseroptikanschl...

Страница 9: ...high speed server connection The lower left slot is for either an optional media expansion module or Stacking Module Up to four switch units can be stacked together using Stacking Modules When the Ma...

Страница 10: ...dule while the lower right slot can be used for a media expansion module Note that the media expansion modules include a Fast Ethernet fiber optic module with two 100BASE FX SC type ports or a one por...

Страница 11: ...ce If you intend to mount the switch in a rack make sure you have all the necessary mounting screws brackets bolts and nuts and the right tools Check if network cables and connectors needed for instal...

Страница 12: ...upper slot by removing the two screws with a flat head screwdriver 3 Before opening the package that contains the module touch the bag to the switch casing to discharge any potential static electrici...

Страница 13: ...he slot along the guide rails ensuring that it firmly engages with the connector 6 If you are sure the module is properly mated with the connector tighten the retainer screws to secure the module in t...

Страница 14: ...r standard 10 Mbps Ethernet connections or 100 ohm Category 5 cable for 100 Mbps Fast Ethernet connections 3 Connect one end of the cable to the RJ 45 port of the network interface card and the other...

Страница 15: ...ort When connecting fiber cable to a Gigabit fiber optic port on the switch be sure you use an SC type connector Follow the steps below Warning This switch uses lasers to transmit signals over fiber o...

Страница 16: ...to any input voltage within the range marked on the rear panel 3 The switch performs a self diagnostic test upon power on Note that this test takes several minutes to complete Note The unit supports a...

Страница 17: ...tus LEDs on the switch panel should be on indicating that the modules are installed and operating correctly Verify that all attached devices have a valid connection The switch monitors the link status...

Страница 18: ...Functions This switch provides fully transparent bridging functions It automatically learns node addresses that are subsequently used to filter and forward all traffic based on the destination address...

Страница 19: ...24 RJ 45 100BASE TX ports Indicator Panel System Power RDP Mgmt Ports link speed disabled partitioned activity duplex flow control Dimensions 440 x 285 x 64 mm 17 37 x 11 22 x 2 53 in Weight 4 5 kg 9...

Страница 20: ...old Modules Management Module AC ES3726M AGENT System Configuration Configuration via console connection to serial port or via Telnet Web based management via HTTP protocol to access embedded manageme...

Страница 21: ...nformance IEEE 802 3z Communication Rate 1000 Mbps Communication Mode Full or half duplex Output Power Minimum 9 5 dBm Maximum 3 dBm Receiver Sensitivity Minimum 20 dBm Saturation 3 dBm Power Budget 1...

Страница 22: ...switch port may be defective Verify that the switch and attached device are powered on Be sure the cable is plugged into both the switch and corresponding device Verify that the proper cable type is u...

Страница 23: ...ters 328 feet Straight Through Wiring If the twisted pair cable is to join two ports and only one of the ports has an internal crossover MDI X the two pairs of wires must be straight through Crossover...

Страница 24: ...d to take whatever measures are required to correct the interference You may use unshielded twisted pair UTP for RJ 45 connections Category 3 or greater for 10Mbps connections and Category 5 for 100Mb...

Страница 25: ...nd flicker in low voltage supply system according to EN 61000 3 3 1995 Immunity Product family standard according to EN 55024 1998 Electrostatic Discharge according to EN 61000 4 2 1995 Contact Discha...

Страница 26: ...sse Optische Sicherheit Niemals ein bertragungslaser betrachten w hrend dieses eingeschaltet ist Niemals direkt auf den Faser TX Anschlu und auf die Faserkabelenden schauen w hrend diese eingeschalte...

Страница 27: ...Zeitraum nicht benutzt sollten Sie es vom Stromnetz trennen Somit wird im Falle einer berspannung eine Besch digung vermieden 12 Durch die L ftungs ffnungen d rfen niemals Gegenst nde oder Fl ssigkeit...

Страница 28: ...Module with 2 100BASE FX SC type Ports EM4582 SX SC Media Module with 1 1000BASE SX SC type Port EM4582 LX SC Media Module with 1 1000BASE LX SC type Port EM3580 STACK Stacking Module kit including 30...

Страница 29: ......

Страница 30: ...AC ES3726M E012002 R01 F2 476 150200008100A...

Отзывы: