Swimming Pool Heat Pump – S series
HOW TO USE THE AUTOMATIC MODE
CAUTION: Before you begin, make sure the filter pump is in a state of operation.
Step 1: Press
once to turn on your pump.
Step 2:Press
to select from one mode to the other until you see the Automatic mode.
Step 3: Use
or
to select the desired temperature (8-40 ° C).
Example
If you chose the value 27 ° C, the screen will display:
Once the symbol
stops flashing, the
requested
temperature will be validated and
up to the temperature of the water
current (in our example 25 °).
Your screen will display:
Good to know about the operation of the automatic mode
Automatic Cooling:
When the temperature of the incoming water is greater than or equal to the required
tempe (X +2) ° C, the compressor will enter cooling mode. The compressor stops
when the temperature of the incoming water will be equal to the required temperature.
Automatic heating:
When the water temperature is less than or equal to the required temperature-X
°
C
,
the
compressor will enter heating mode. The compressor stops when the temperature of the
incoming water will be equal to the required temperature.
Attention : Following the selection of heating or cooling mode, the current program can not
be changed in 10 minutes.
Directions for setting range X and Y
X: parameter adjust from 2 ° to 10 ° C, the default setting is 3 ° C
Y: parameter adjust from 0 ° to 6 ° C, the default setting is 0 °
Flash
Requested temp.
Current ambient temp.
Current water temp.