GENERAL
When installing or intervening on the chiller unit, it is necessary to strictly follow the rules listed in this manual, to observe all the
indications on the unit and however to take all possible precautions. Failure to comply with the rules reported on this manual can
create dangerous situations.
After receiving the unit, immediately check its integrity. The unit left the factory in perfect condition; any damage
must be immediately reported to the carrier and recorded on the Delivery Note before signing it.
The company must be informed, within 8 days, of the extent of the damage. The Customer should prepare a written statement of
any severe damage.
CAUTION: The units are designed for outdoor installation. The outside temperature must never exceed 46°C. Beyond
this value, the unit is no longer covered by the current regulations in the field of safety of pressure equipment.
CAUTION: The installation place must be without any fire risks. Therefore all the necessary measures should be
adopted in order to prevent the risk of fire at the installation place. The appliance must not be placed near naked
flames and ignition sources
CAUTION: The unit must be installed so as to allow free movement for repair and maintenance operations. The
warranty does not cover costs for platforms or other lifting equipment needed for any interventions.
All the maintenance operations and tests must be done by QUALIFIED PERSONNEL ONLY.
Before any operation on the unit, make sure that power is disconnected.
Do not use equipment to speed up the defrost process or for cleaning except for those recommended by the
manufacturer
The appliance must be placed in a room without ignition sources constantly running (for example naked flames, a
running gas-fired appliance or a running electric heater)
Do not perforate or burn
CAUTION: There are some moving components inside the unit. Pay the utmost attention when operating in their
vicinity, even if power is disconnected.
The heads and delivery pipe of the compressor are normally quite hot.
Be careful when working near the condensing coils.
The aluminium fins are very sharp and can cause serious injuries.
After the maintenance operations, close the panels by fixing them with screws.
5.2
LIFTING AND HANDLING
During unloading and positioning of the unit, utmost care must
be taken to avoid abrupt or violent manoeuvres in order to
protect the internal electronic components. The units can be
lifted by means of a forklift or, in alternative, with belts, being
sure not to damage the side panels and the cover. It is
important to keep the unit horizontal during these operations.