41
Water circuit
Water content of hydronic circuit
L
3,0
3,0
3,0
3,0
Maximum water side pressure
bar
6
6
6
6
Plumbing fittings
inch
1"M
1"M
1"M
1"M
Minimum water volume
L
60
70
70
70
Nominal circulator output
kW
0,14
0,14
0,14
0,14
Maximum circulator output
kW
0,14
0,14
0,14
0,14
Max circulator absorbed current
A
1,10
1,10
1,10
1,10
Energy Efficiency Index (EEI) circulator
≤ 0,23
≤ 0,23
≤ 0,23
≤ 0,23
Noise level
Sound power level L
w
(8)
dB(A)
68
68
68
68
Sound pressure level at a distance of 1m
Lp1 (9)
dB(A)
52,7
52,7
52,7
52,7
Sound pressure level at a distance of 10m
L
p10
(9)
dB(A)
36,6
36,6
36,6
36,6
Electrical data
Power supply
400V/3P+N+
T/50Hz
230V/1/50Hz 400V/3P+N+
T/50Hz
400V/3P+N+
T/50Hz
Maximum input power
kW
6,6
7,0
7,0
8,3
Maximum input current
A
9,5
30,4
10,1
12,0
Maximum input power with antifreeze kit
kW
6,7
7,1
7,1
8,5
Maximum input current with antifreeze
kit
A
9,7
31,0
10,3
12,2
Dimensions and
weights
A - Length
mm
1044
1044
1044
1044
B - Depth
mm
448
448
448
448
C - Height
mm
1409
1409
1409
1409
Shipping weight
kg
148
140
154
154
Operating weight
kg
136
126
141
141
Performance referring to the following conditions, according to standard 14511:2018:
(1) Cooling: outdoor air temperature 35°C; in/out water temperature 12/7°C.
(2) Cooling: outdoor air temperature 35°C; in/out water temperature 23/18°C.
(3) Heating: outdoor air temperature 7°C db 6°C db; in/out water temp 30/35°C.
(4) Heating: outdoor air temperature 7°C db 6°C db; in/out water temp 40/45°C.
(5) Cooling: in/out water temperature 7/12°C.
(6) Heating: average climatic conditions; Tbiv=-7°C; in/out water temp 30/35°C.
(7) Indicative data subject to changes. For the correct value, always refer to the technical label on the unit.
(8) Sound power level: heating mode condition (3); value determined based on measurements made in accordance with standard UNI EN ISO 9614-2, compliant
with that required by the Eurovent certification.
(9) Sound pressure level: value calculated from the sound power level using ISO 3744:2010
(*) activating the maximum Hz function
N.B. performance data are indicative and are subject to change. Furthermore the performance declared in points (1), (2), (3)
and (4) is intended to refer to instantaneous power according to EN 14511. The value declared in point (5) and (6) is determined
according to UNI EN 14825.
CAUTION: The minimum temperature allowed for storing the units is 5°C.
11.2
UNIT AND AUXILIARY ELECTRICAL DATA
Unit power supply
V/~/Hz
230/1PH+PE/50*-
400/3PH+PE/50**
Remote controller circuit
V/~/Hz
12/1/50
On board controller circuit
V/~/Hz
12/1/50
Fans power supply
V/~/Hz
230/1/50
For sizes 06, 08, 10, 12, 14 and 16* - For sizes 10T, 12T 14T, 16T
NOTE: The electrical data are subject to change due to updates. It is therefore always necessary to refer to the technical
specifications label applied on the right side panel of the unit.