Other essential safety requirements
Electrical equipment.
After the various assembly stages, all warm air heaters are subjected to the following electrical checks to verify compliance:
-
visual check of the electrical circuit and tightening of the connections;
-
continuity of the earth circuit;
-
insulation resistance test;
-
voltage test.
Temperatures.
The temperatures of the accessible areas for normal use of the warm air heater comply with the European reference standard.
Noise.
All the necessary measures have been taken to contain noise.
The values in dB (A) are shown in the tables Chapter:
TECHNICAL DATA.
Reports.
The signals on the controls and on the alarm devices are made with graphic symbols according to the ISO7000 standard.
For an explanation of the symbols used, refer to the Chapter Explanation of Graphic Symbols on page. 4.
At the beginning of each heating season and, according to the deadlines set by law and regulations, the operator must have
the efficiency of all functional and safety parts of the machine checked by specialized personnel and have the combustion
checked.
The results of these interventions will be recorded in the "central booklet".
The air filter, if provided, must be kept clean frequently to keep it clean.
It must be removed from its frame, blown with compressed air (see MAINTENANCE chapter) and put back in its frame.
When the air intake grille is dirty, it must be cleaned with a brush or vacuum cleaner without however removing it.
REFERENCE STANDARDS, DIRECTIVES AND REGULATIONS
The manufacturer declares that the machine is built in a workmanlike manner based on UNI, UNI technical
standards CIG, CEI; is according to:
-
to GAR 2016/426 (EU),
-
the Machinery Directive 2006/42 / EC,
-
the Low Voltage Directive 2014/35 / EU,
-
the Electromagnetic Compatibility Directive 2014/30 / EU,
-
to ECODESIGN: Directive 2009/125 / EC,
-
ErP REGULATION 2016/2281 / UE, STEP II °
SOME REFERENCE STANDARDS AND LAWS:
- UNI-CIG 7129 for natural gas installations
- UNI-CIG 7131 for LPG installations
- EN 17082: 2019
- Law 10/91 for the containment of energy consumption
- Law 46/90 for plant safety
- Ministerial Decree 08/11/2019 technical rule of fire prevention
Содержание AS COND
Страница 39: ...39 ELECTRICAL DIAGRAMS AS COND EX...
Страница 40: ...40 AS COND 80 100 150 175 200...
Страница 41: ...41 AS COND EX 250...
Страница 42: ...42 AS COND 300 600...
Страница 52: ...52...
Страница 53: ...53...
Страница 54: ...54...
Страница 55: ...55...