background image

16

User's Manual

Replacing and Upgrading Hard Drives

Q4:

A4:

What should I do if I need to replace a defective hard drive?

1. To minimize the risk of losing data, make it a practice to keep a spare hard drive 

  of the same brand and model for the next three to five years. Always restock  

  your spare inventory with new hard drive(s) of the same model whenever a  

  defective hard drive is replaced.
2. If your replacement drives are the same manufacturer as the original drives but

are a larger capacity, place the surviving drive in the upper bay where it will be 

designated as the source drive. Boot the PC from the upper bay source drive. 

When the operating system is ready to serve, insert the replacement drive into 

lower bay. The disk auto rebuild procedure will now start. If it fails to start, switch 

the front panel operation mode switch from Single to Dual.

For normal operation, always put the smaller capacity drive in upper bay and 

larger capacity drive in lower bay. Never place the larger capacity drive in the 

upper bay.

  

 Tip:

 Label each tray with the disk capacity, brand, and model for future reference.

3. CASE STUDY:

 

● 

Company ABC uses two Seagate Family ST3250823AS (Seagate250GB) 

    drives on one ARAID disk array.

 

● 

Company ABC should keep an inventory of spare ST3250823AS drives.

 

● 

Company ABC experiences a Seagate250GB disk crash and has no more

ST3250823AS to replace. Instead a new Seagate Family ST3300622AS 

(Seagate250GB) is available for replacement. For daily operation, the smaller 

drive, the Seagate250GB, needs to be put in upper bay and the larger drive, 

the Seagate300GB, must be put in the Lower Bay as a mirrored couple. 

In this scenario, the mirror couple of Seag Seagate300GB, its 

effective capacity is 250GB. RAID 1 disk array capacity is always defined by 

the capacity of the smaller drive.

 

● 

For Windows User ONLY: 

If at some later point the 2nd drive Seagate250GB malfunctions and the 

Seagate300GB is the surviving drive, you can enlarge the Seagate300GB’s 

partition size from 250GB to 300GB by using a third party’s program, such as 

Symantec's Ghost or Partition Magic. Then mirror it to another Seagate300GB 

and gather a 300GB disk capacity.

Содержание araid 3500

Страница 1: ......

Страница 2: ...1 8 Operating with Single Mode RAID 1 9 Switching from Single Mode to Dual Mode RAID 1 9 Performing a Manual Mirror On Demand Fan Temperature and RAID Management 10 Family Products Add IDE Bridge 11 A...

Страница 3: ...full extent However if users cannot obtain identical types of drives users may use newer drives made by same manufacturer No Need to pre FORMATTING Brand New Drives When using ARAID 3500 S3500 you do...

Страница 4: ...O NOT set switch for RAID 0 operation Although RAID 0 operation requires two on line drives the Single mode is not allowed Use a small piece of tape to mistakenly switch to Single mode which causes da...

Страница 5: ...mediately for any missing or damaged item 1 Mobile rack 1 in upper bay 2 Mobile rack 2 in lower bay 3 Two security keys 4 Bag of screws 5 User s Manual 6 RS232 cables one set 7 Software CD 3 Managemen...

Страница 6: ...rts SNMP function for standard network management Equipped with a quiet powerful 6cm silent and cooling fan with durability strong suction and silent sound Supports 7200 RPM drives Power Requirements...

Страница 7: ...rm On Off Switch ARAID 3500 S3500 Front View 1 6cm silent and cooling fan 2 UR1 RS 232 port to USB connector 3 R1 Legacy 9 pin RS 232 port 4 SATA II connector connects to PC 5 15 pin power socket 6 Ju...

Страница 8: ...ter few seconds the ARF operation will start 4 ARF progress is shown in percentage on the LCD display 5 Maximum ARF rate reaches 230 300 GB hour under optimal conditions 6 After the new drive is rebui...

Страница 9: ...boot the system from primary HDD But when the primary drive fails ARAID will boot the system from secondary HDD a Two drives are installed Switch in Dual mode b System boots from the drive marked as O...

Страница 10: ...ess it Switch in Single mode OFF indicates power for secondary drive is OFF 2 Even two drives are installed ARAID only access the Primary drive because the power of Secondary drive is still OFF Switch...

Страница 11: ...about the hard drive cooling fan speed temperature status and etc In addition it can notify users by e mail when there is irregular warning happen so the users can monitor the status of devices operat...

Страница 12: ...Connector DB 9 2 ARAID T3500 TS3500 External model b Rear View a Front View IDE Bridge Jumper Setting Mode J1 J2 MASTER Close Open SLAVE Open Close Power Supply Unit 63W Standalone PSU Power Consumpti...

Страница 13: ...ect SATA port of motherboard to the Rear slot of PC USB 3 0 e SATA Interface choose either interface to use 1 USB 3 0 Connector 2 e SATA Connector USB 2 0 Interface 1 USB 2 0 Connector IDE Interface 1...

Страница 14: ...ase replace both drives as soon as possible When the drive in upper bay is in progress rebuilding to the drive in lower bay if ARAID discover bad sectors on the source hard drive ARAID LCD shows Meanw...

Страница 15: ...drive in upper bay until 100 complete System will continue operating normally without being affected After complete the rebuilding due to the hard drive in the upper bay has bad sectors we recommend u...

Страница 16: ...nd new one Warning Please do not forget to backup the HDD s data first before executing this step Preventing and recovering from an unexpected virus attack Q3 A3 How can I prevent or recover from a vi...

Страница 17: ...ace the larger capacity drive in the upper bay Tip Label each tray with the disk capacity brand and model for future reference 3 CASE STUDY Company ABC uses two Seagate Family ST3250823AS Seagate250GB...

Страница 18: ...ARAID product with my existing equipment or O S and compatibility occurs what should I do As some users would use ARAID product with existing equipment or O S might be old system and compatibility pro...

Страница 19: ...or AMI Chipset HDD 1 Brand Model Series number HDD 2 Brand Model Series number IDE operation Mode CPU RAM Version of Windows Linux other Benchmark Application if available Mandatory Optional but it he...

Страница 20: ...2 22 23 23 23 24 Jumper 24 ARF 25 HDD 25 Dual 26 Single 27 Single Dual 27 ARAID RAID 28 29 IDE 29 ARAID3500 T3500 TS3500 29 31 Q A 33 33 ARAID S3500 HDD PC 33 34 ARAID OS 35 Accordance 36 V1 4 www acc...

Страница 21: ...20 ARAID 3500 S3500 ARAID 3500 S3500 RAID 1 RAID 0 2 3 5 FDISK FORMAT Auto Rebuild 6 7200rpm 2 RAID PC SATA II 3Gb 3Gb 2010 8 SATA II 3G SATA I 1 5G...

Страница 22: ...irror On Demand RAID 1 Dual RAID 1 ARAID 3500 S3500 2 Single ARAID 3500 S3500 M i r r o r O n Demand RAID 0 Dual RAID 0 RAID 0 2 Single RAID 0 RAID 0 2 ARAID ON OFF S3500 ARAIDS3500 HDD HDD PC ARAID R...

Страница 23: ...22 ARAID 3500 S3500 ARAID 3500 S3500 1 2 RS232 1 4 CD1 a ARAID SMART Araid Eye b Araid Manager c SNMP Agent for Windows ARAID 3500 S3500...

Страница 24: ...M USB USB RS 232 4 SNMP 5 6 7200rpm 5V 12V ARAID S3500 ARAIDS3500 PC ARAID IDE IDE GTP HDD 195mm 146mm 86mm 0 7 0 C 55 C 20 C 70 C Intel OADG Pentium III II Pentium MMX Pentium ATA II 3G IDE Serial SA...

Страница 25: ...500 1 LCD 2 3 HD1 R W LED 1 4 HD2 R W LED 2 5 Buzzer On Off Jumper 1 2 3 4 5 ARAID 3500 S3500 1 6 2 UR1 USB RS 232 3 R1 9 RS 232 4 SATA II PC 5 SATA 6 Jumper Mode J1 J2 RAID 0 Close Open RAID 1 Open C...

Страница 26: ...PC 2 OS Windows Linux 2 ARF 2 OFF LCD 3 A R F 4 ARF LCD 5 ARF 230 300 GB 6 OK LCD ARF LCD HDD Western Digital HDD ARAID HDD http www accordance com tw News SUPPORT WD NAS HDD WD Red WD Red Pro WD Re W...

Страница 27: ...26 RAID 1 ARAID RAID 1 1 ARAID Pri HD1 2 ARAID 3500 S3500 ARAID a b 1 02 ARAID 1 HDD...

Страница 28: ...27 ARAID RAID 1 1 1 ARAID ARAID OFF OFF OFF ARAID 2 2 OFF ARAID OFF OFF RAID 1 Mirror On Demand OFF OFF...

Страница 29: ...g Analysis and Reporting Technology ARAID ARAID Eye ARAID 2 Bad Sector ARAID etc etc ARAID SMART ARAID 3 ARAID SNMP Agent Linux version A c c o r d a n c e S y s t e m s 2000 2003Server XP Pro Redhat...

Страница 30: ...29 IDE a 1 2 3 RS 232 DB9 ARAID 3500 HIDE S3500 HIDE ARAID T3500 TS3500 b IDE Bridge Jumper Mode J1 J2 MASTER Close Open SLAVE Open Close 63W HDD 5 14W 7 32W 240 mm 183 2mm 156 15mm 2 68...

Страница 31: ...30 SATA SATA SATA PC USB 3 0 e SATA 1 USB 3 0 2 e SATA USB 2 0 1 USB 2 0 IDE 1 IDE 2 IDE PC 3 PC ARAID T3500 S3500 SATA eSATA USB IDE ARAID T3500 TS3500 ARAID T3500 TS3500...

Страница 32: ...31 RAID 1 1 2 3 4 5 LCD LCD ARAID 3500 S3500 LCD ARAID 3500 S3500 LCD ARAID 3500 S3500 HDD HDD ARAID HDD ARAID A R A I D 100 HDD HDD...

Страница 33: ...32 6 7 8 HDD ARAID ARAID HDD HDD HDD HDD ARAID HDD ARAID A R A I D 100 HDD HDD HDD ARAID ARAID HDD HDD...

Страница 34: ...33 A2 S3500 HDD PC Accordance Q3 A3 ARAID RAID 1 1 3 ARAID ARAID 2 Accordance Q A RAID Q1 A1 UPS PC OS Q2 ARAID S3500 HDD PC HDD PC ARAID...

Страница 35: ...622AS 300GB ST3250823AS ST3300622AS Seagate250GB Seagate300GB 250GB Windows Seagate250GB Seagate300GB 250GB HDD 300GB HDD 300GB 250GB Windows Windows Windows Symantec GHOST or Partition Magic ST330062...

Страница 36: ...35 ARAID OS Q5 A5 OS ARAID Accordance...

Страница 37: ...36 Accordance PC BIOS Phoenix Award AMI HDD 1 HDD 2 IDE SATA CPU RAM OS Windows Linux etc 1 2 3 1 2 3 Accordance Serial Number Firmware Revision ARAID...

Страница 38: ...AID 1 43 43 Dual RAID 1 44 Single RAID 1 45 Single Dual Mirror On Demand 45 ARAID 46 IDE 47 ARAID T3500 TS3500 48 RAID1 49 Q A For RAID 1 User 51 51 ARAID S3500 51 ARAID MIRROR ON DEMAND 51 51 ARAID 5...

Страница 39: ...3500 S3500 ARAID 3500 S3500 1 0 RAID Level 1 0 SATA II 3 0G SATA I 1 5G SATA II 3G Seagate SeaTools 3 5 FDISK FORMAT Auto Rebuild 6 7 200rpm ARAID S3500 ARAID S3500 enable security PC ARAID S3500 Rai...

Страница 40: ...39 RAID 0 Dual RAID 0 Disk Stripe Dual Single RAID 0 RAID 0 Single Single RAID 1 Dual RAID 1 Disk Mirror ARAID Single ARAID Mirror On Demand ARAID Single Dual Mirror ARAID Dual Single...

Страница 41: ...40 1 ARAID 3500 S3500 2 1 5 2 6RS232 3 7 4 3 a ARAID SMART Araid Eye b Araid Manager c SNMP Agent for Windows ARAID 3500 S3500...

Страница 42: ...V ARAID S3500 security S3500 enable security S3500 PC ARAID S3500 Raid System IDE ARAID S3500 ARAID 3500 Bridge IDE GPT 3500 S3500 195mm 146mm 86mm 5 25 Bay 0 7 0 C 55 C 20 C 70 C Intel Based IBM Pent...

Страница 43: ...le Dual 3 HD1 LED Read Write LED 4 HD2 LED Read Write LED 5 Buzzer On Off Jumper 1 6 2 UR1 USB RS 232 3 R1 9Pin RS 232 4 SATA II 5 15 Pin 6 Jumper J1 J2 RAID 0 Close Open RAID 1 Open Close 7 ARAID 350...

Страница 44: ...ngle Dual 1 2 Windows RedHat Linux Switch Dual Single LCD OFF 3 4 LCD 5 230 300 Giga Bytes 6 LCD O K LCD ARAID http www accordance com tw News SUPPORT Western Digital WD NAS WD Red WD Red Pro WD Re WD...

Страница 45: ...44 Switch Dual 1 LCD Pri HDD1 Switch Dual Dual RAID 1 2 ARAID 3500 S3500 RAID 1 ARAID 3500 S3500 a LCD Switch b LCD Switch LCD 02 Rebuilding Switch Switch Switch...

Страница 46: ...45 Single Dual Mirror On Demand Switch Dual LCD Switch Single Dual Disk Rebuild source Switch Single 1 LCD Switch Single OFF Single RAID 1 LCD Switch Single OFF 2 LCD Switch Single OFF...

Страница 47: ...LCD T ARAID 65 C 149 F ARAID SMART Araid Eye ARAID Rebuilding Rebuilding SNMP Agent MIB MIB II Trap Linux SNMP Agent ARAID 3500 S3500 Windows 2000 Server 2003 XP Redhat SUSE Linux ARAID HP OpenView IB...

Страница 48: ...7 IDE ARAID 3500 HIDE S3500 HIDE ARAID T3500 TS3500 1 2 AC110 220V 3 RS232 DB 9 IDE Bridge Jumper Setting Mode J1 J2 MASTER Close Open SLAVE Open Close 63W 5 14W 7 32W 240mm x 183 2mm x 156 15mm 2 68k...

Страница 49: ...48 ARAID T3500 TS3500 ARAID T3500 TS3500 for SATA eSATA USB IDE SATA 1 SATA USB 3 0 e SATA 1 USB 3 0 2 e SATA USB 2 0 1 USB 2 0 IDE 1 IDE 2 3 ARAID...

Страница 50: ...49 RAID 1 ARAID LCD ARAID LCD ARAID ARAID LCD ARAID ARAID LCD ARAID...

Страница 51: ...50 ARAID LCD ARAID LCD ARAID ARAID 100 ARAID LCD ARAID 100 ARAID LCD ARAID...

Страница 52: ...Sec Pri Source Pri Sec ARAID 3500 S3500 switch Dual ARAID S3500 Q2 A2 ARAID S3500 ARAID Firmware Firmware ARAID S3500 HDD ARAID S3500 HDD HDD HDD HDD ARAID Mirror On Demand Q3 A3 ARAID Auto Rebuild Ac...

Страница 53: ...250823AS Seagate Family ST3300622AS Seage 300GB Seage250GB Seage 300GB Seage250GB Seage 300GB RAID 1 250GB For Windows User ONLY Seage 250GB Seage 300GB Windows Symantec s Ghost Partition Magic Seage...

Страница 54: ...Brand Model BIOS Phoenix or Award or AMI Chipset HDD 1 Brand Model Series number HDD 2 Brand Model Series number IDE operation Mode CPU RAM OS Version of Windows or Linux or Benchmark Application if a...

Страница 55: ...54 MEMO...

Страница 56: ...55 MEMO...

Страница 57: ...56 MEMO...

Страница 58: ......

Отзывы: