background image

XC111-XR111 Evaluation Kit – User Guide 

 

 

 

 

Page 24 of 24 

 
 
© 2018 by Acconeer – All rights reserved 

 

2018-08-10 

8  Disclaimer 

The information herein is believed to be correct as of the date issued. Acconeer AB (“

Acconeer

”) will 

not be responsible for damages of any nature resulting from the use or reliance upon the information 
contained herein. Acconeer makes no warranties, expressed or implied, of merchantability or fitness 
for a particular purpose or course of performance or usage of trade. Therefore, it is the user’s 
responsibility to thoroughly test the product in their particular application to determine its performance, 
efficacy and safety. Users should obtain the latest relevant information before placing orders.  

Unless Acconeer has explicitly designated an individual Acconeer product as meeting the requirement 
of a particular industry standard, Acconeer is not responsible for any failure to meet such industry 
standard requirements. 

Unless explicitly stated herein this document Acconeer has not performed any regulatory conformity 
test. It is the user’s responsibility to assure that necessary regulatory conditions are met and approvals 
have been obtained when using the product. Regardless of whether the product has passed any 
conformity test, this document does not constitute any regulatory approval of the user’s product or 
application using Acconeer’s product.  

Nothing contained herein is to be considered as permission or a recommendation to infringe any 
patent or any other intellectual property right. No license, express or implied, to any intellectual 
property right is granted by Acconeer herein. 

Acconeer reserves the right to at any time correct, change, amend, enhance, modify, and improve this 
document and/or Acconeer products without notice.

  

This document supersedes and replaces all information supplied prior to the publication hereof. 

 

Acconeer AB 

 

www.acconeer.com 

IDEON Gateway 

[email protected] 

Scheelevägen 27 

+46 10 218 92 00 

223 63 LUND 
Sweden

Содержание XC111

Страница 1: ...XC111 XR111 Evaluation Kit XC111 Evaluation Board XR111 Sensor Board User Guide...

Страница 2: ...luation Kit User Guide Page 2 of 24 2018 by Acconeer All rights reserved 2018 08 10 XC111 XR111 Evaluation Kit XC111 Evaluation Board XR111 Sensor Board User Guide Author Acconeer Version 1 6 2018 08...

Страница 3: ...oad 5 2 2 SW API Description 5 3 The EVK Hardware 6 3 1 XC111 Connector Board 7 3 1 1 Overview 7 3 1 2 Power 8 3 1 3 Electrical Schematics 9 3 1 4 List of Materials 14 3 1 5 Pinning 15 3 2 XR111 Senso...

Страница 4: ...comes fully integrated in a small package of 29 mm2 The A111 can measure absolute distance with mm accuracy up to a range of 2m with a continuous sweep update frequency of up to 1500 Hz The A111 60 G...

Страница 5: ...Acconeer SW comes with an API Application Programming Interface Acconeer provides several service oriented example applications as well as customer guidelines for application development when utilizi...

Страница 6: ...igure 1 shows a block diagram for the EVK RESET_N_RP RESET_N A111 24MHz XTAL XC111 Connector GPIO5_SK ENABLE RESET_N SPI bus 1 8V Raspberry Pi Connector Stepdown Voltage converter 5V Level Shifters EN...

Страница 7: ...018 by Acconeer All rights reserved 3 1 XC111 Connector Board The XC111 is Acconeer s Connector board and part of the EVK 3 1 1 Overview Picture 1 shows the XC111 connector board front side including...

Страница 8: ...10 Picture 2 shows the reverse side of the XC111 R1003 R1106 shows the resistors connected to the GPIO for measurement purposes 3 1 2 Power The Evaluation Kit is powered through the Raspberry Pi When...

Страница 9: ...C111 XR111 Evaluation Kit User Guide Page 9 of 24 2018 08 10 2018 by Acconeer All rights reserved 3 1 3 Electrical Schematics On the following pages please find the electrical schematics for the XC111...

Страница 10: ...XC111 XR111 Evaluation Kit User Guide Page 10 of 24 2018 by Acconeer All rights reserved 2018 08 10...

Страница 11: ...XC111 XR111 Evaluation Kit User Guide Page 11 of 24 2018 08 10 2018 by Acconeer All rights reserved...

Страница 12: ...XC111 XR111 Evaluation Kit User Guide Page 12 of 24 2018 by Acconeer All rights reserved 2018 08 10...

Страница 13: ...XC111 XR111 Evaluation Kit User Guide Page 13 of 24 2018 08 10 2018 by Acconeer All rights reserved...

Страница 14: ...C14 C19 C24 C28 C30 CAPM1005_055_1 11 100nF C31 C32 CAPM1005_055_1 2 1uF C100 C101 CAPM1005_055_1 2 10pF C1 C12 C25 C26 CAPM1608_090_1 14 10uF X5 CON_HDR_2X20_254_1_REVERSE 1 X6 CON_HDR_2X20_254_2 1...

Страница 15: ...7 Not Connected 8 Not Connected 9 GND 10 Not Connected 11 Not Connected 12 Not Connected 13 Sensor Enable 14 GND 15 Not Connected 16 Not Connected 17 3 3V 18 Sensor 3 GPIO5 19 SPI_MOSI 20 GND 21 SPI_M...

Страница 16: ...I bus shall communicate with 36 SPI_SS0 In combination with SPI_SS1 and SPI_SS_RP this signal selects which sensor the SPI bus shall communicate with 37 Not Connected 38 Sensor 1 GPIO5 39 GND 40 Senso...

Страница 17: ...X111 Evaluation Kit User Guide Page 17 of 24 2018 08 10 2018 Acconeer All rights reserved 3 2 2 Electrical Schematics Below please find the electrical schematic for the XR111...

Страница 18: ...111R2A 1 C11 C12 CAPM0603_033_1 2 8pF C13 C15 CAPM0603_033_1 3 100nF C17 C19 CAPM0603_033_1 3 TP_1 TESTPOINT 1 B1 TSX 3225 1 24MHz 3 2 4 Pinning Table 2 shows the PIN connections for XR111 Pin Number...

Страница 19: ...8 by Acconeer All rights reserved Pin Number Description 24 VIO 25 GND 26 GND 27 GND 28 Pin B1 NC 29 GND 30 Pin A2 NC 31 GND 32 GND 33 GND 34 GPIO0 35 GND 36 GPIO3 37 GND 38 VIO 39 Not Connected 40 GN...

Страница 20: ...hts reserved 2018 08 10 4 Design considerations The EVK was designed for sensor evaluation purposes only Should you want to design a product it is strongly recommended to carefully read and follow the...

Страница 21: ...2018 08 10 2018 by Acconeer All rights reserved 5 Safety 5 1 Electrostatic precautions Please take electrostatic precautions including using ground straps when using the EVK or any of its components...

Страница 22: ...unication Commission Not Performed Japan Technical Regulations of Radio Law of Japan Not Performed EU Electromagnetic Compatibility Directive Not Performed South Korea Kc Korea certification Not Perfo...

Страница 23: ...y changed from 26MHz to 24MHz 2018 04 16 1 3 Updated XR111 Schematic so that the crystal oscillator has 24MHz frequency and not 26MHz Updated XR111 BOM with comment that the crystal oscillator frequen...

Страница 24: ...failure to meet such industry standard requirements Unless explicitly stated herein this document Acconeer has not performed any regulatory conformity test It is the user s responsibility to assure th...

Отзывы: