5.4.6 Sounder commands
These commands control the ATR110
’s sounder (beep).
Table 8. Sounder commands
Command
Description
Default
Parameters/Range
AISGBF
‘Good Beep’ frequency.
2
0 - 700 Hz
1 - 1400 Hz
2 - 2800 Hz
AISGBD
‘Good Beep’ active duration.
Each unit is equivalent to 100
milliseconds.
5
0
–100
AISGBS
‘Good Beep’ silence duration.
Each unit is equivalent to 100
milliseconds.
1
0
–100
AISGBN
‘Good Beep’ number of beeps.
1
0
–5
AISGBV
‘Good Beep’ volume.
2
0 - Off
1 - Low
2 - Medium
3
– High
AISBBF
‘Bad Beep’ frequency.
0
0 - 700 Hz
1 - 1400 Hz
2 - 2800 Hz
AISBBD
‘Bad Beep’ active duration.
Each unit is equivalent to 100
milliseconds.
4
0
–100
AISBBN
‘Bad Beep’ number of beeps.
3
0
–5
AISBBS
‘Bad Beep’ silence duration.
2
0
–100 milliseconds
AISBBV
‘Bad Beep’ volume.
3
0 - Off
1 - Low
2 - Medium
3 - High
5.5 Development commands
5.5.1 Firmware and imager levels
The firmware levels identify the release and build of a unit. Send the command
AISFWV?
to obtain
this information. For example: SB 01.00.00 is a first generation ATR110.
To check the latest firmware version or to update firmware, contact
Table 9. Firmware and imager commands
Command
Description
Default
Parameters/Range
AISXXR
Simulates read outcome.
Used in Interactive mode to
communicate to the user after the host
has checked the data.
Only applicable to Interactive mode and
Host mode.
-
0 - Good Read
1 - Bad Read
2 - Ignore