Page
32
of
70
Copyright © Access-IS 2016
Command
Description
Default
Parameters/Range
AISTST
Soft trigger timeout.
Specifies how long the ATR110
retains barcode information before
discarding.
Only used with
AISOMD1
or
AISOMD2
.
2000
1000
–25000
milliseconds
AISTPT
Presentation trigger timeout.
Specifies how long the imager will
wait before reading a new
barcode.
1000
1000
–30000
milliseconds
SNSSMO
Sensor maximum on time.
Each unit is equivalent to 100
milliseconds (600 = 60 seconds).
If the infrared sensor detects
media for more than the timeout
(for example, because there is a
sticker on the glass), it is disabled
allowing the imager to work in
presentation mode.
600
0 (feature disabled)
1
–60000
AISTRE
Enable document detect trigger.
Warning:
This is for
advanced users only and
modification may cause the
device to become inoperable.
1
0 - Disabled
1 - Enabled
5.6.1 Interactive mode
The commands to trigger the ATR110 for Interactive mode do not follow the same format as
described in Table 11. For Interactive mode, trigger commands are sent as
[0x16][0x74][0x0D]
and
[0x16][0x75][0x0D]
instead of the
[0x16][0x4D][0x0D]
command.
Table 12. Triggering commands for Interactive mode
Command
Description
Default
Parameters/Range
[0x16][0x74][0x0D]
Triggers the ATR110.
-
-
[0x16][0x75][0x0D]
Untriggers the ATR110.
This cannot be done when
media is detected by the
ATR110.
-
-
5.7 Counter
These commands display the number of ‘Good’ or ‘Bad’ reads made by the device.
Table 13. Counter commands
Command
Description
Default
Parameters/Range
AISGRC
‘Good Read’ counter.
Cannot be reset.
0
-
AISBRC
‘Bad Read’ counter.
Cannot be reset.
0
-