background image

Page 1-1

Manual MPCI-ICM4S.F1b

Chapter 1:  Introduction

These cards provide effective asynchronous serial communications in RS422 and RS485 networks
on long communications lines in noisy environments. The cards feature independent serial ports and
use type 16550 buffered UARTs. The data lines are opto-isolated from the computer and from each
other to assure communication through large common mode noise.  

Both the RS422 and RS485 cards are 12.283 inches (312 mm) long and may be installed in 5-volt
PCI-bus slots of IBM PC or compatible computers. For Windows compatibility, the cards feature
automatic control in the RS485 mode to transparently enable/disable the transmission drivers. 

RS422 Balanced Mode Operation

The PCI-ICM422/2 and PCI-ICM422/4 support RS422 communications and use differential
balanced drivers for long cables and high noise immunity. These cards also have the capability to
add load resistors to terminate the communications lines.  RS422 communications requires that a
transmitter supply a bias voltage to ensure a known "zero" state.  Also, receiver inputs at each end
of the network should be terminated to eliminate "ringing".  These cards support biasing by default
and support termination by jumpers on the card.  If your application requires the transmitter to be
un-biased, please contact the factory.

RS485 Balanced Mode Operation

The PCI-ICM485/2 and PCI-ICM485/4 support RS485 communications and also use differential
balanced drivers for long range and high noise immunity.  RS485 operation involves switchable
transceivers and the ability to support multiple devices on a single  "party line".  The RS485
specification defines a maximum of 32 devices on a single line.  The number of devices served on
a single line can be expanded by use of "repeaters".

PCI-ICM485/2 and PCI-ICM485/4 also have the capability to add load resistors to properly terminate
the communications lines.  Receiver inputs at each end of the network should be terminated to
eliminate 'ringing".  Also, RS485 communications requires that one transmitter supply a bias voltage
to ensure a known "zero" state when all transmitters are off. These cards support biasing by default
and support termination by jumpers on the card.  If your application requires the transmitter to be
un-biased, please contact the factory.

COM Port Compatibility

Type 16550 UARTs are used as the Asynchronous Communication Element (ACE).   These include
a 16-byte transmit/receive buffer to protect against lost data in multitasking operating systems, while
maintaining 100 percent compatibility with the original IBM serial port.

Содержание PCI-ICM422/2

Страница 1: ...ACCES I O PRODUCTS INC 10623 Roselle Street San Diego CA 92121 TEL 858 550 9559 FAX 858 550 7322 MODEL PCI ICM422 485 2 4 USER MANUAL FILE MPCI ICM4S F1b...

Страница 2: ......

Страница 3: ...his document may contain or reference information and products protected by copyrights or patents and does not convey any license under the patent rights of ACCES nor the rights of others IBM PC PC XT...

Страница 4: ...not excluded by warranty Warranty commences with equipment shipment Following Years Throughout your equipment s lifetime ACCES stands ready to provideon site or in plant service at reasonable rates si...

Страница 5: ...apter 2 Installation 2 1 CD Installation 2 1 3 5 Inch Diskette Installation 2 1 Directories Created on the Hard Disk 2 2 Installing the Card 2 4 Input Output Connections 2 5 Chapter 3 Option Selection...

Страница 6: ...d Termination Schematic Page 3 1 Figure 3 2 Option Selection Map Page 3 3 Figure A 1 Typical RS485 Two Wire Multidrop Network Page A 3 List of Tables Table 5 1 Baud Rate Divisor Values Page 5 2 Table...

Страница 7: ...and support termination by jumpers on the card If your application requires the transmitter to be un biased please contact the factory RS485 Balanced Mode Operation The PCI ICM485 2 and PCI ICM485 4 s...

Страница 8: ...port by port basis One range is for up to 115 200 baud applications and the other is for up to 460 800 baud applications Refer to Baud Rate Divisor Table on page 5 2 of the manual Auto RTS Transceive...

Страница 9: ...hat terminateswith female D sub 9 pin connectors Character length 5 6 7 or 8 bits Parity Even odd or none Stop Interval 1 1 5 or 2 bits Serial Data Rates Up to 115 200 baud asynchronous A faster range...

Страница 10: ...PCI ICM422 2 4 and 485 2 4 Manual Page 1 4 Manual MPCI ICM4S F1b Figure 1 1 PCI ICM422 2 4 Block Diagram Only one serial channel shown Figure 1 2 PCI ICM485 2 4 Block Diagram...

Страница 11: ...ompts to install the software for this card WIN95 98 NT 2000 a Place the CD into your CD ROM drive b The CD should automatically runthe install programafter 30 seconds If the install program does not...

Страница 12: ...of CARDNAME that contains C samples Win32 language Subdirectories containing samples for Win95 98 and NT WinRISC exe A Windows dumb terminal type communication program designed for RS422 485 operatio...

Страница 13: ...n programs in DOS PCIFind exe A utility for DOS and Windows to determine what base addresses and IRQs are allocated to installed PCI cards This program runs two versions depending on the operating sys...

Страница 14: ...e installed in a five volt PCI slot of an IBM or compatible computer Before carefully read the Option Selection section of this manual and configure the card according to your requirements Finally our...

Страница 15: ...ee foot long breakout cable is included with the cards Thatbreakout cable terminates in separate 9 pinDBM connectors oneDB9 per port If desired the cards can be purchased without this breakout cable I...

Страница 16: ...PCI ICM422 2 4 and 485 2 4 Manual Page 2 6 Manual MPCI ICM4S F1b...

Страница 17: ...elect baud rates in either of two ranges When in the X1 position the baud rate range is up to 115 200 baud When in the X4 position the baud rate range is 200 to 460 800 baud Refer to the Baud Rate Div...

Страница 18: ...vices REG_SZ COM5 InterruptStatus REG_DWORD 0xFC08 InterruptStatus REG_DWORD 0xFC08 PortIndex REG_DWORD 1 PortIndex REG_DWORD 3 Indexed 0 Indexed 0 Serial3 subkey Serial5 subkey PortAddress REG_DWORD...

Страница 19: ...Page 3 3 Manual MPCI ICM4S F1b Figure 3 2 Option Selection Map...

Страница 20: ...PCI ICM422 2 4 and 485 2 4 Manual Page 3 4 Manual MPCI ICM4S F1b...

Страница 21: ...etected on the PCI bus the addresses assigned toeach function on each of the cards and the respective IRQs and DMAs if any allotted Alternatively some operating systems Windows95 98 2000 can be querie...

Страница 22: ...PCI ICM422 2 4 and 485 2 4 Manual Page 4 2 Manual MPCI ICM4S F1b...

Страница 23: ...izing the chip requires knowledge of the UART s register set The first step is to set the baud rate divisor You do this by first setting the DLAB Divisor Latch Access Bit high This bit is Bit 7 at Bas...

Страница 24: ...mper Baud Rate Divisor x1 Divisor x4 Notes Max Diff Cable Length 460800 N A 1 230400 N A 2 153600 N A 3 115200 1 4 375 feet 57600 2 8 660 ft 38400 3 12 920 ft 28800 4 16 1165 ft 19200 6 24 1620 ft 144...

Страница 25: ...u do this with two reads from the receiver buffer at base address 0 When done the UART is ready to use Reception Reception can be handled in two ways polling or interrupt driven When polling reception...

Страница 26: ...ASEADDR 2 if readback 4 Readback will be set to 4 if data are available data i inportb BASEADDR outportb 0x20 0x20 Write EOI to 8259 Interrupt Controller return Transmission RS485 transmission is simp...

Страница 27: ...and Rx 3 Tx Tx and Rx 4 5 Ground Ground 6 7 8 9 Rx Table 6 1 Connector Pin Assignments The cards can be ordered without the breakout cable In that case your communication cables will connect directly...

Страница 28: ...PCI ICM422 2 4 and 485 2 4 Manual Page 6 2 Manual MPCI ICM4S F1b...

Страница 29: ...ble This is also true for RS422 but RS485 offers all the benefits of RS422 plus allows up to 32 devices to share the same twisted pairs An exception to the foregoing is that multiple RS422 devices can...

Страница 30: ...x Driver Output Voltage unloaded 4V 6V 4V 6V Driver Output Voltage loaded LD and LDGND 2V jumpers in 2V Driver Output Resistance 50S Driver Output Short Circuit Current 150 mA Driver Output Rise Time...

Страница 31: ...e following illustration shows a typical multidrop or party line network Note that the transmission line is terminated on both ends of the line but not at drop points in the middle of the line Figure...

Страница 32: ...PCI ICM422 2 4 and 485 2 4 Manual Page A 4 Manual MPCI ICM4S F1b...

Страница 33: ...accesioproducts com Customer Comments If you experience anyproblems with this manual or just want to give us some feedback pleaseemail us at manuals accesioproducts com Please detail any errors you fi...

Отзывы: