OMNISOUND
®
3000C PRO USER MANUAL
5
COPYRIGHT © 2001 - 2017, ACCELERATED CARE PLUS CORP., ALL RIGHTS RESERVED
Over ischemic tissues in individuals with vascular disease where the blood supply would be unable to
follow the increase in metabolic demand
Over areas of recent bleeding or hemorrhage
Over areas of active tuberculosis
ULTRASOUND WARNINGS & PRECAUTIONS
CAUTION: Federal law restricts this device for sale or use by, or on the order of, a Practitioner
licensed by the laws of the state in which he/she practices to use or order the use of the device.
Please notice that Accelerated Care Plus cannot provide medical advice. If you have specific
medical questions, please contact your healthcare professional.
Warnings
Do not operate this device until the User Manual, including all Indications for Use, Contraindications, Warnings
and Precautions, have been carefully read and understood.
Operation of this device or placement of lead wires, probes, pads and electrodes in close proximity (less than 5
feet) to an operating shortwave or microwave diathermy unit may produce instability in the device output or
burns at the treatment site. Since the patient may not feel the 27 MHz frequency, they lack the protective
sensation and tissue burns could result. Short-wave field could potentially damage or reset medical devices in
close proximity to the drum applicator.
Treatment should not be applied over the carotid sinus nerves, (located in the anterior neck triangle), including,
stellate ganglion, vagus nerve, or laryngeal or pharyngeal muscle. Particular care should be taken for patients
with a known sensitivity to the carotid sinus reflex, as carotid sinus stimulation may alter blood pressure and
cardiac contractility.
Do not apply treatment over heart. Thermal/sub-thermal treatment may affect organ function.
Treatment should not be applied when high fever is present.
Do not apply over the lumbar or abdominal region, or over the uterus during menstruation as therapy may
temporarily increase menstrual flow.
Treatment should not be applied directly over external stimulator systems.
The treatment head should be moved continuously during treatment to avoid discomfort and burns.
An appropriate coupling medium should be employed in order to ensure energy transmission to the tissue.
Precautions
Application site and settings should be based on the guidance of the prescribing practitioner.
All equipment and accessories should be kept out of the reach of children or unqualified persons.
Do not connect this device to any wall outlet that has not been properly grounded, or to any electrically non-
isolated medical device.
Use only ACP specified accessories and/or supplies with ACP devices. Do not use any power cords, or power
supplies, other than the ones provided or specified for this device. Use of any other power supply could
seriously damage the device and will void the warranty.
When cleaning the device, never immerse them or wash them with water. See the infection control section in
this manual for cleaning instructions. Devices should not be submerged in water or other liquids.
Содержание 1203000C
Страница 1: ......
Страница 3: ......
Страница 23: ...20 OMNISOUND 3000C PRO USER MANUAL COPYRIGHT 2001 2017 ACCELERATED CARE PLUS CORP ALL RIGHTS RESERVED...
Страница 37: ......