background image

 

 

 

- 2 - 

 

 
 
 

!!! PRECAUTIONS!!! 

(Please read it before using) 

 

When using  the  ETOS-XP series, please read  this  manual and  the  relevant  manuals  introduced  in 
this manual, and handle devices correctly paying attention to safety. 
The precautions described in this manual are only for the ETOS-XP series. 

 

[Instructions for Commercial (Class A) Device] 

Device Type 

User Instruction 

Class A Devices  

(Commercial Broadcasting 

Communication Devices) 

This is a device for commercial use (Class A) that is 
registered for electromagnetic wave conformity, so sellers/ 
users must pay attention to this point. 

 

Safety precautions are classified into "Danger" and "Precaution". 

Danger 

If improper handling may result in a hazardous situation or possible death or 
serious injury. 

Precaution 

If improper handling may result in a hazardous situation, moderate injury or 
minor injury or material damage only. 

Note that even those items listed in the "Precaution" may lead to serious consequences (dangers) 
depending on the situation. Please be sure to observe  the safety precautions since all of them 
are important contents to keep. 
 
In order to use ETOS-XP products efficiently and safely, please read and understand the following 
contents before use. 
The contents describe the installation  of the product, wiring and operating environment  and the 
risks and precautions for disposal. 
 
 

 
 

 

[Normal] 

Dangers 

 

When working for communication cable, keep a distance of at least 100mm away from the power 
supply cable. 

 

Please pay attention to the rated power supply  for each product. In particular, for  the 
products that receive DC 24V input, be sure to  enter DC 24V in consideration of (+) and 
(-) polarity. Inputting AC power supply may cause breakdown. 

 

If power supply of the product is AC, be sure to use the grounded power supply.  

 

Do not use any products that are damaged or deformed during opening. It may cause breakdown 
of the product. 

 

Do not drop or give a shock to the product. It may cause damage or breakdown of the product. 

 

Please  keep  and  use  the  products  under  the  environmental  conditions  described  in  this 
manual.  In  particular,  it  may  cause  breakdowns  in  environments  where  vibration,  dust, 
corrosive  gas  or  dew  may  form.  Therefore,  use  in  the  environment  within  the  specified 
dimensions. 

 

When working on the communication cable, make sure to know the pin layout diagram in this 
manual  before  wiring.  For  the  other  party’s  devices  to  where  ETOS-XP  products  and 
communication line will be connected, thoroughly examine the contents of the communication 
line beforehand before operation. 

 

Dispose of the products as industrial waste. 

The manufacturer shall not be liable for the accidents generated because of 

not learning the “Dangers” and “Precautions” properly.

 

Содержание ETOS-XP Series

Страница 1: ...1 Industrial Network Server ETOS XP Series ETOS XP SERIES USER S GUIDE AC T System Co Ltd 2017 06 Revision 1 1...

Страница 2: ...roduct wiring and operating environment and the risks and precautions for disposal Normal Dangers When working for communication cable keep a distance of at least 100mm away from the power supply cabl...

Страница 3: ...e sure to shut off the power supply from the outside before installing or removing the module card Failure to do so may result in electric shock or damage to the product Do not directly touch the cond...

Страница 4: ...s while Operating Precautions When controlling the ETOS XP series in operation read this user s manual thoroughly and check the safety Incorrect parameter setting or program change may cause breakdown...

Страница 5: ...ut prior notice to improve the function of the product Revision History Revision No Date Change 1 0 2016 08 First Edition 1 1 2017 06 Revision AC T Systems Co Ltd 16 11 LS ro 91beon gil Dongan gu Anya...

Страница 6: ...6 OVERVIEW CHAPTER1 This chapter introduces the functional features of ETOS XP CONTENTS 1 1 Product Overview 1 2 Main Features 1 3 Products list...

Страница 7: ...er memory for communication data storage and conversion Communication frame monitor memory Monitor and variable monitor function Program function for protocol conversion among heterogeneous equipment...

Страница 8: ...00XP E22 Ethernet 1port electric RS 232 2port RS 422 RS 485 2port ETOS 100XP E04 Ethernet 1port electric RS 422 RS 485 4port ETOS 100XP S40 RS 232 4port ETOS 100XP S22 RS 232 2port RS 422 RS 485 2port...

Страница 9: ...NUL COVER Empty Slot cover 1 3 1 Maximum Number of Supported Ports The maximum number of serial and Ethernet ports supported by product is as follows Product 100XP 150XP 500XP Ethernet 10 100Base T X...

Страница 10: ...hium Battery 2 years External lithium Battery 2 years External lithium Battery 2 years Ethernet 1 Port 2 Port 2 Port 4 Port Serial additional option 4 Port 4 Port 20 Port WatchDog Built in Built in Bu...

Страница 11: ...ER2 This chapter describes general function specifications Contents 2 1 General Specification 2 2 Power supply Specification 2 3 Battery Specification 2 4 Cable Specification 2 5 Communication Specifi...

Страница 12: ...ibration IEC 60068 2 6 Frequency Acceleration Amplitude Number of Occurrence 10 f 57 0 075mm 10 times in each direction of X Y Z 57 f 150 9 8 1G Shock Resistance Maximum impact acceleration 147 15G Ap...

Страница 13: ...16 6 ETOS 500XP O XL 050F Lithium 3 6V 1 2A 28 x 16 6 2 3 2 Precautions for Use 1 Do not charge disassemble heat put into fire short circuit solder or give a shock to the battery 2 Handling battery i...

Страница 14: ...ble to backup up to 2 hours with the internal super cap charged for 3 days or more so be sure to complete the battery replacement within 2 hours The order of the battery exchange and the related photo...

Страница 15: ...OS 500XP Battery assembly can be done in reverse order of disassembly Unscrew battery cover to open the mounting cover Remove the mounting cover from the holder Open the battery compartment of the mou...

Страница 16: ...and communication speed The following table lists the recommended cable specifications Electrical Feature Appearance Item Unit Single Wire Stranded Wire Conductor No of Core Wire Pair 2 2 Specificati...

Страница 17: ...Cable Use Item Name UTP Cable Type Name Enhanced CAT 5 4P Specification 4P Pair X 24AWG Recommended Cable Specification In order to guarantee the Ethernet communication speeds you must use the cables...

Страница 18: ...e Cable Maker LG Cable Hewlett Packard H P Structure Fiber Size Core Cladding 62 5 125 Connector Style L C Cable Type Dual Channel Maximum Attenuation 5 dB km Standard Attenuation 4 5 dB km N A Numeri...

Страница 19: ...CD 2 5 2 Serial RS 232 RS 422 RS 485 Item Specification Data Bit 7 or 8 Stop Bit 1 or 2 Start Bit 1 Parity Even Odd None Space Mark Synchronization method Asynchronous method Transmission Rate BPS 20...

Страница 20: ...GREEN Mode LED Blink during SW Run Remote run STAT YELLOW Status LED ON at the warning state STOP RED Mode LED On at Stop mode 2 6 2 ETOS 150XP 2 6 2 1 ETOS 150XP LED LED Status Name LED Color Operat...

Страница 21: ...OW ON at the warning state OFF at normal state STOP RED On at Stop OFF at other states RUN 2 6 4 ETOS 500XP LED SIO 2 6 4 1 SIO RS 232 4Port LED LED Status Description Name Color Operating Status Seri...

Страница 22: ...t RX of Serial CH1 TX2 GREEN ON at TX of Serial CH2 RX2 YELLOW ON at RX of Serial CH2 TX3 GREEN ON at TX of Serial CH3 RX3 YELLOW ON at RX of Serial CH3 422 YELLOW ON at RS 422 mode Err RED ON at fram...

Страница 23: ...TX2 GREEN ON at TX of Serial CH2 RX2 GREEN ON at RX of Serial CH2 422 YELLOW ON at RS 422 mode Err RED ON at frame error TX3 GREEN ON at TX of Serial CH3 RX3 GREEN ON at RX of Serial CH3 422 YELLOW ON...

Страница 24: ...This chapter explains specifications required for installation and wiring of ETOS XP Series Contents 3 1 Power Supply and Connector ETOS 100XP 150XP 3 2 Power Supply and Connector ETOS 500XP 3 3 Ether...

Страница 25: ...AC100 240V power input through the power connector in front of the product as shown in the following picture ETOS 100XP ETOS 150XP Input power supply AC 100V 240V Free Voltage 50 60 Hz Power supply mu...

Страница 26: ...as follows 1 8 Pin No Name Signal Direction Function Description 1 TD Transmit Ethernet 2 TD Transmit Ethernet 3 RD Receive Ethernet 4 N A 5 N A 6 RD Receive Ethernet 7 N A 8 N A RJ 45 Connector Plug...

Страница 27: ...S 232 serial port of the ETOS XP series Serial Port Specification for RS 232 of ETOS XP Series 1 8 Pin No Name Signal Direction Function Description 1 CD DCE notifies DTE of detected carrier 2 RXD Rec...

Страница 28: ...RS 232 port of ETOS XP series must be connected as in the following picture 3 TxD 5 SG 2 RxD 3 TxD 5 SG 2 RxD ETOS RJ 45 1 2 3 4 5 6 7 8 9 1 8 Connection Diagram of RS 232 Null Modem When hardware ha...

Страница 29: ...D RS 422 Transmit Data 2 TXD RS 422 Transmit Data 3 RXD RS 422 Receive Data 4 RXD RS 422 Receive Data 5 SG1 Signal Ground1 6 TXD RS 422 Transmit Data 7 TXD RS 422 Transmit Data 8 RXD RS 422 Receive Da...

Страница 30: ...ion of ETOS XP Series Pin No Name Signal Direction Function Description 1 3 6 8 TRX RS 485 Transmit Receive Data 2 4 7 9 TRX RS 485 Transmit Receive Data The following figure shows the RS 485 connecti...

Страница 31: ...31 Appendix Dimension A 1 ETOS 100XP 150XP Unit mm...

Страница 32: ...32 A 2 ETOS 500XP Unit mm...

Отзывы: