• The LED display flashes [ 0.0 ] and [ 0:00 0.0 ] when measuring in grams and the
timer is idle.
• The LED display flashes [ 0.00
0
] and [ 0:00 0.000 ] when measuring in ounces and
the timer is idle.
• When the weight exceeds 999 grams, the LED display only shows the integer part (the
decimal point will not be displayed). The LED display shows up to a maximum of 3000
grams. If the weight exceeds 3000 grams, the scale will display [ Maximum ].
• When an object (such as a cup) weighing two grams or more is placed on the scale and
the weight reading is stable, the scale will perform auto tare.
• After the scale detects the flow of espresso, the timer will start. The timer will stop when
the espresso flow stops.
• When the espresso is ready and the cup is removed, the display will flash between the
beverage weight and the vessel weight.
Note
1. In Espresso Mode, the timer will stop when the espresso flow stops.
2. The auto-tare function is performed only when the weight exceeds two grams.
3. If you leave the scale idle for ten seconds, it will reset the timer and perform tare
operation.
4. In Espresso Mode, the timer will also stop when a negative weight (i.e., removal
of a cup) is detected.
Mode 5 - Espresso Mode
Mode Description
Display
Action
Operation
Start / Stop / Reset Timer
Tap Power button
Tare Weight
Tap Tare button
Reset Mode
Double tap Tare button
Switch between Grams / Ounces
Press and hold Tare button
Switch Mode
Press and hold Power button
11
This mode is designed to aid espresso extraction.
The scale automatically tares the weight of the
vessel. It will then detect the start of the flow of
espresso into the vessel and automatically start
the timer function; the timer stops when the flow of
espresso into the vessel stops.