Technical Information

2

.2 INSTALLATION PARTS CHECKING

No.

Name

No.

Name

1

Indoor unit

8

Sealing gum

2

Outdoor unit

9

Wrapping tape

3

Connection pipe

10

Support of outdoor 
unit

4

Drainage pipe

11

Fixing screw

5

Wall mounting 
frame

12

Drainage plug (cooling 
and heating unit)

6

Connecting cable 
(power cord)

13

Owners manual, 
remote controller

7

Wall pipe

!

Note: 

•  Please contact the local agent for installation.
• Don’t use unqualified power cord.

2

.3 SELECTION OF INSTALLATION 

       LOCATION

1. Basic Requirement:

Installing the unit in the following places may cause 
malfunction. If it is unavoidable, please consult the local dealer:

a. The place with strong heat sources, vapors, flammable or 

explosive gas, or volatile objects spread in the air.

b. The place with high-frequency devices (such as welding

machine, medical equipment).

c. The place near coast area.
d.  The place with oil or fumes in the air.
e. The place with sulfureted gas.
f. Other places with special circumstances.

2. Indoor Unit:

a. There should be no obstruction near air inlet and air outlet.
b.  Select a location where the condensation water can be 

dispersed easily and wont affect other people.

c.  Select a location which is convenient to connect the outdoor 

unit and near the power socket.

d.  Select a location which is out of reach for children.
e. The location should be able to withstand the weight of indoor 

unit and wont increase noise and vibration.

f. The appliance must be installed 72inch above floor.
g. Dont install the indoor unit right above the electric appliance.
h. The appliance shall not be installed in the laundry.

3.  Outdoor Unit:

a. Select a location where the noise and outflow air emitted by 

the outdoor unit will not affect neighborhood.

b. The location should be well ventilated and away from strong

wind.

c. The location should be able to withstand the weight of 

outdoor unit.

d. Make sure that the installation follows the requirement of 

installation dimension diagram.

e.  Select a location which is out of reach for children and far 

away from animals or plants.If it is unavoidable, please add
fence for safety purpose.

2

.4 REQUIREMENTS FOR 

ELECTRIC CONNECTION

1. Safety Precaution

a. Must follow the electric safety regulations when installing

the unit.

b. According to the local safety regulations, use qualified
power supply circuit and air switch.
c. Make sure the power supply matches with the 

requirement of air conditioner. Unstable power supply or 
incorrect wiring may result in electric shock,fire hazard
or malfunction. Please install proper power supply cables
before using the air conditioner.

d.  Properly connect the live wire, neutral wire and grounding

wire of power socket.

e. Be sure to cut off the power supply before proceeding any 

work related to electricity and safety.

f. Do not put through the power before finishing installation.
g. For appliances with type Y attachment,the instructions

shall contain the substance of thefollowing.If the 
supply cord is damaged,it must be replaced by the 
manufacturer,its service agent or similarly qualified
persons in order to avoid a hazard.

h. The temperature of refrigerant circuit will be high, please 

keep the interconnection cable away from the copper 
tube.

2. Grounding Requirement:

a.  The air conditioner is first class electric appliance. It must

be properly grounding with specialized grounding device 
by a professional. Please make sure it is always grounded
effectively, otherwise it may cause electric shock.

b.  The yellow-green wire in air conditioner is grounding wire, 

which cant be used for other purposes.

c. The grounding resistance should comply with national

electric safety regulations.

d. The appliance must be positioned so that the plug is

accessible.

e.  An all-pole disconnection switch having a contact

separation of at least 1/8 inch in all poles should be 
connected in fixed wiring.

f. Including an air switch with suitable capacity, please note 

the following table. Air switch should be included magnet
buckle and heating buckle function, it can protect the 
circuit-short and overload. (Caution: please do not use the 
fuse only for protect the circuit)

Air-conditioner

Air switch capacity

09K

25 A

12K

35 A

2

.5 INSTALLATION OF INDOOR UNIT

1. Choosing Installation Iocation

Recommend the installation location to the client and then 
confirm it with the client.

2. Install Wall-mounting Frame

a. Hang the wall-mounting frame on the wall; adjust it in

horizontal position with the level meter and then point out
the screw fixing holes on the wall.

b. Drill the screw fixing holes on the wall with impact drill

(the specification of drill head should be the same as
the plastic expansion particle) and then fill the plastic
expansion particles in the holes.

!

Содержание AWH09QB-A3DNA5K/O

Страница 1: ...AC Pro 19 12k 115V A Series Service Manual Models AWH09QB A3DNB8K I AWH09QB A3DNA5K O AWH12QC A3DNB8K I AWH12QC A3DNA5K O Refrigerant R410A...

Страница 2: ...We reserve the right to correct any clerical errors Copyright 2018 AC pro...

Страница 3: ...5 Universal meter 6 Torque wrench open end wrench inner hexagon spanner 7 Electronic leakage detector 8 Vacuum pump 9 Pressure meter 10 Pipe pliers pipe cutter 11 Pipe expander pipe bender 12 Solderi...

Страница 4: ...98 7 16 inch At least 5 7 8 inch At least 5 7 8 inch Space to the wall S p a c e t o t h e o b s t r u c t i o n r o o l f e h t o t e c a p S A t l e a s t 1 1 8 i n c h Space to the obstructio At le...

Страница 5: ...it Bind up pipes and hang the indoor unit Install the support of outdoor unit select it according to the actual situation Fix outdoor unit Make the bound pipes pass through the wall hole and then conn...

Страница 6: ...safety regulations use qualified power supply circuit and air switch c Make sure the power supply matches with the requirement of air conditioner Unstable power supply or incorrect wiring may result...

Страница 7: ...4 51 32 55 31 4 Connect the Pipe of Indoor Unit a Aim the pipe joint at the corresponding bellmouth As show in Fig 5 b Pretightening the union nut with hand c Adjust the torque force by referring to...

Страница 8: ...power and then separate the drain hose As show in Fig 15 3 Bind them evenly 4 The liquid pipe and gas pipe should be bound separately at the end 9 Hang the Indoor Unit 1 Put the bound pipes in the wa...

Страница 9: ...d black brown brown black yellow green green yellow green green Screw Cable Cross Plate Sub assy Valve Cover U shaped curve Wall Drain hose Note The wiring connect is for reference only please refer t...

Страница 10: ...aced in water 1 Use Vacuum Pump 1 Remove the valve caps on the liquid valve and gas valve and the nut of refrigerant charging vent 2 Connect the charging hose of piezometer to the refrigerant charging...

Страница 11: ...t F4 4 5 Overload limit drop frequency F5 5 7 Over current limit drop frequency F6 6 3 High exhaust temperature limit drop frequency F8 8 1 Refrigerant leakage protection F9 9 2 Anti freezing limit dr...

Страница 12: ...on diagnosis process Start End Is the wiring terminal between the temperature sensor and the controller loosened or poorly contacted Is there a short circuit due to trip over of the parts Replace the...

Страница 13: ...oltage of this foot to neutral wire on the mainboard 53 enance s the control terminal of PG motor connected tightly s the feedback interface of PG motor connected tightly otor can t operate is broken...

Страница 14: ...n and Mainten 3 Malfunction of Protection of Jumper Cap C5 Main detection points Is there jumper cap on the mainboard Is the jumper cap inserted correctly and tightly The jumper is broken The motor is...

Страница 15: ...e IDU Fan Motor U8 Main detection points Instant energization after de energization while the capacitor discharges slowly Is the zero cross detection circuit of the mainboard defined abnormal Malfunct...

Страница 16: ...ctric box are correctly connected Correct connection Connect the line according to wiring diagram Malfunction eliminated NO Main board matches with display board Main board of IDU matches with that of...

Страница 17: ...alfunction of detecting plate WIFI JF Start Check if the connection wire are correctly connected Replace the detecting plate with the same model Malfunction eliminated YES Replace the detecting plate...

Страница 18: ...the AC voltage between terminal L and N on wiring board XT power supply Shut down the power and wait 20 minutes or use DC voltmeter to measure the voltage on the two ends of capacitor or until the vol...

Страница 19: ...the connection in correct order Is the voltage input of the machine within normal range Use AC voltmeter to measure the voltage between terminal L and N on wiring board XT Is the compressor coil resi...

Страница 20: ...structed by other objects which affect the heat exchange of indoor and outdoor unit 2 If the indoor and outdoor fans working normally 3 If the environment temperature is too high this will result in t...

Страница 21: ...utdoor ambient temperature higher than 53 20 minutes after the complete unit is powered off Is heat dissipation of the indoor unit and outdoor unit abnormal Does the outdoor fan work normally Replace...

Страница 22: ...r stopping enough Fault diagnosis process Power on the unit Is stop time of the compressor longer than 3 minutes Does startup fail Are the wires for the compressor connected correctly Is connection se...

Страница 23: ...ressor connected correctly Is connection sequence right Is the connection made in clockwise direction Is fault is eliminated Replace the control panel AP1 Replace the compressor End YES YES Connect th...

Страница 24: ...after the complete unit is powered off NO Is the terminal FA for the electronic expansion valve connected correctly Resistances between the first four pins close to the terminal hole and the fifth pin...

Страница 25: ...it Is the resistance around zero Remove the PFC capacitor and measure resistance between the two terminals Disconnect the terminals for the reactor and measure the resistance between the two terminals...

Страница 26: ...ure occurred Check wiring inside of the indoor and outdoor units Are wires broken Check the communication circuit of the outdoor unit The communication circuit is abnormal Replace the main board of th...

Страница 27: ...stem Filth blockage ice plug greasy blockage cut off valve hasn t been opened completely Is the compressor running abnormally Is there an abnormal sound or oil leakage Is the temperature of the shell...

Страница 28: ...and outdoor unit is improper Check whether the installation postion is proper according to installation requirement for air conditioner Adjust the installation position and install the rainproofing an...

Страница 29: ...replace compressor Cylinder of compressor is blocked Compressor canot operate Repair or replace compressor 6 Air Conditioner is Leaking Possible Causes Discriminating Method Air conditioner Status Tro...

Страница 30: ...nance 10 Exploded View and Parts List 10 1 Indoor Unit 29 28 27 30 2 4 9 10 7 12 13 15 16 17 18 19 20 21 22 23 25 26 8 1 3 5 11 14 24 6 6 31 The component picture is only for reference please refer to...

Страница 31: ...200004407 0100297601 1 13 Wall Mounting Frame 01252043 01252484 1 14 Cross Flow Fan 10352059 10352056 1 15 Fan Motor 1501208902 1501214605 1 16 Connecting Pipe Clamp 2611216401 2611216401 1 17 Drainag...

Страница 32: ...for reference please refer to the actual product Service Manual 12 13 14 11 1 2 4 6 7 8 9 10 18 15 16 17 33 19 22 21 20 25 24 26 3 23 5 28 27 29 31 30 32 34 AWH12QC A3DNA5K O AWH09QB A3DNA5K O The co...

Страница 33: ...100005 1 15 Valve Support 01713041 01713041 1 16 Valve 07100003 1 17 Cable Cross Plate sub assy 02123015 02123015 1 18 Cover of pass wire 01413069 01413069 1 19 Magnet Coil 4300040021 4300040021 1 20...

Страница 34: ...nt panel Panel rotation Groove 91 Installation and Maintenance 11 1 Removal Procedure of Indoor Unit after turning off all power supplies and discharge the refrigerant completely before removal a b Ax...

Страница 35: ...ecting plate WIFI Installation and Maintenance Service Manual a b Remove the screws fixing front case Note 1 Open the screw caps before removing the screws around the air outlet 2 The quantity of scre...

Страница 36: ...inal Lift up the main board and take it off 8 Remove electric box assy Electric box Electric box assy Clasps Shield cover of electric box sub assy Cold plasma generator Water retaining sheet Grounding...

Страница 37: ...then pull the terminal Circlip Soft sheath Holder Connector Procedure Steps Remove 3 screws fixing evaporator assy 9 Remove evaporator assy Screws Connection pipe clamp Evaporator assy Evaporator assy...

Страница 38: ...ve screw fixing step motor then remove step motor Service Manual Procedure Steps Remove the screws fixing motor clamp and then remove the motor clamp Remove the screws at the connection place of cross...

Страница 39: ...A3DNA6E O for example 96 Installation and Maintenance 11 2 Removal Procedure of Outdoor Unit Procedure Steps 1 Remove cable cross plate sub assy and valve cover 3 Remove front grille 2 Remove top cov...

Страница 40: ...the valve support and the electric box Then remove the right side plate front panel right side plate 97 nstallation and Maintenance 4 Remove front panel 5 Remove right side plate 6 Remove axial flow b...

Страница 41: ...ard sub assy to remove motor motor support electric box assy clapboard sub assy 98 Installation and Maintenance Service Manual 7 Remove motor and motor support 8 Remove electric box assy 9 Remove clap...

Страница 42: ...rthe 4 weld spots connecting the 4 way Valve Assy to take it out Note Refrig erant shouldbe discharged firstly Welding processshould be as quickly as possible and keepwrapping cotton wet all the time...

Отзывы: