4
Technical Information
2
.2 INSTALLATION PARTS CHECKING
No.
Name
No.
Name
1
Indoor unit
8
Sealing gum
2
Outdoor unit
9
Wrapping tape
3
Connection pipe
10
Support of outdoor
unit
4
Drainage pipe
11
Fixing screw
5
Wall mounting
frame
12
Drainage plug (cooling
and heating unit)
6
Connecting cable
(power cord)
13
Owners manual,
remote controller
7
Wall pipe
!
Note:
• Please contact the local agent for installation.
• Don’t use unqualified power cord.
2
.3 SELECTION OF INSTALLATION
LOCATION
1. Basic Requirement:
Installing the unit in the following places may cause
malfunction. If it is unavoidable, please consult the local dealer:
a. The place with strong heat sources, vapors, flammable or
explosive gas, or volatile objects spread in the air.
b. The place with high-frequency devices (such as welding
machine, medical equipment).
c. The place near coast area.
d. The place with oil or fumes in the air.
e. The place with sulfureted gas.
f. Other places with special circumstances.
2. Indoor Unit:
a. There should be no obstruction near air inlet and air outlet.
b. Select a location where the condensation water can be
dispersed easily and wont affect other people.
c. Select a location which is convenient to connect the outdoor
unit and near the power socket.
d. Select a location which is out of reach for children.
e. The location should be able to withstand the weight of indoor
unit and wont increase noise and vibration.
f. The appliance must be installed 72inch above floor.
g. Dont install the indoor unit right above the electric appliance.
h. The appliance shall not be installed in the laundry.
3. Outdoor Unit:
a. Select a location where the noise and outflow air emitted by
the outdoor unit will not affect neighborhood.
b. The location should be well ventilated and away from strong
wind.
c. The location should be able to withstand the weight of
outdoor unit.
d. Make sure that the installation follows the requirement of
installation dimension diagram.
e. Select a location which is out of reach for children and far
away from animals or plants.If it is unavoidable, please add
fence for safety purpose.
2
.4 REQUIREMENTS FOR
ELECTRIC CONNECTION
1. Safety Precaution
a. Must follow the electric safety regulations when installing
the unit.
b. According to the local safety regulations, use qualified
power supply circuit and air switch.
c. Make sure the power supply matches with the
requirement of air conditioner. Unstable power supply or
incorrect wiring may result in electric shock,fire hazard
or malfunction. Please install proper power supply cables
before using the air conditioner.
d. Properly connect the live wire, neutral wire and grounding
wire of power socket.
e. Be sure to cut off the power supply before proceeding any
work related to electricity and safety.
f. Do not put through the power before finishing installation.
g. For appliances with type Y attachment,the instructions
shall contain the substance of thefollowing.If the
supply cord is damaged,it must be replaced by the
manufacturer,its service agent or similarly qualified
persons in order to avoid a hazard.
h. The temperature of refrigerant circuit will be high, please
keep the interconnection cable away from the copper
tube.
2. Grounding Requirement:
a. The air conditioner is first class electric appliance. It must
be properly grounding with specialized grounding device
by a professional. Please make sure it is always grounded
effectively, otherwise it may cause electric shock.
b. The yellow-green wire in air conditioner is grounding wire,
which cant be used for other purposes.
c. The grounding resistance should comply with national
electric safety regulations.
d. The appliance must be positioned so that the plug is
accessible.
e. An all-pole disconnection switch having a contact
separation of at least 1/8 inch in all poles should be
connected in fixed wiring.
f. Including an air switch with suitable capacity, please note
the following table. Air switch should be included magnet
buckle and heating buckle function, it can protect the
circuit-short and overload. (Caution: please do not use the
fuse only for protect the circuit)
Air-conditioner
Air switch capacity
09K
25 A
12K
35 A
2
.5 INSTALLATION OF INDOOR UNIT
1. Choosing Installation Iocation
Recommend the installation location to the client and then
confirm it with the client.
2. Install Wall-mounting Frame
a. Hang the wall-mounting frame on the wall; adjust it in
horizontal position with the level meter and then point out
the screw fixing holes on the wall.
b. Drill the screw fixing holes on the wall with impact drill
(the specification of drill head should be the same as
the plastic expansion particle) and then fill the plastic
expansion particles in the holes.
!