27
PROGRAMMING
TRANSITION TEMPERATURE SETTING
Adjusts the transition threshold between the levels
in the AUTO Mode temperature triggers.
Press the up or down button to cycle through 0°F
to 8°F (0°C to 4°C) and set a transition threshold.
The level will be set one level above the OFF Mode
level when the sensor temperature first meets or
exceeds the high temperature trigger. For every
transition threshold crossed, the level will ramp up
by one level, up until it reaches the level set in ON
Mode.
In this example, your high temperature trigger is set
at 80°F, the OFF Mode level is 0, and the ON Mode
level is 6. If the transition threshold is set to 0°F,
then the devices will trigger to run at level 6 when
the sensor temperature meets or exceeds 80°F.
However, if the transition threshold is set to 2°F,
then the devices will trigger to run at level 1 when it
meets or exceeds 80°F. It will then step up to level
2 when meeting or exceeding 82°F, level 3 at 84°F,
level 4 at 86°F, and level 5 at 88°F. From 90°F on, it
will run at level 6, the level set in ON Mode.
Level