Service
Danger, strong magnetc field!
-
Danger to life for people with heart pacemakers!
-
Do not place runners near cardiac pacemakers, credit cards, data carriers
or similar objects sensitive to magnetic fields!
-
Danger of injury by clamping!
-
Do not place any metal parts near the rotor!
Abyzz pumps are almost maintenance-free when used properly.
Should the flow rate deteriorate, dirt particles may have caught in the impeller,
which must be removed. Light vibrations can also be an indication of impurities in
the impeller. If a complete cleaning is necessary, remove the rotating screws (P5,
P6) and remove the front part of the pump. Please note that when reassembling,
new self-locking nuts must be used.
The protective grille can then be pulled backwards and the motor can be cleaned
(P10). If it is necessary to remove the impeller, unscrew the retaining screw (P8)
with a suitable hexagon socket wrench and pull the impeller from the shaft. This
screw is made of titanium and must not be replaced by another screw! The rear
bearing can be inspected by opening the rear bearing seat (P7).
O-rings and rubber parts are subject to unavoidable aging and should be
exchanged if necessary. These parts can be referred to as spare parts under the
name of the part number.
The pump should be decalcified at regular intervals in
plants which are continually and intensively calcined (for example, steinko coral
basins).
Tip:
We recommend the Abyzz Pump Cleaner for cleaning, so you have the certainty
not to damage your pump.
!
15
Содержание AFC400
Страница 1: ... User Manual AFC400 1 ...
Страница 22: ... Appendix P1 P2 22 ...
Страница 23: ... P3 23 ...
Страница 24: ... P4 24 ...
Страница 25: ... P5 P6 25 ...
Страница 26: ... P7 P8 26 ...
Страница 27: ... P9 P10 27 ...
Страница 28: ... 28 ...
Страница 29: ... 29 ...
Страница 30: ... WWW ABYZZ DE 30 ...