6.7 Patrol
Stored preset positions can be combined together into pre-defined tours. Up to four tours can be configured.
Each tour can contain up to eight presets. A tour can be activated permanently in the live view and executed
regularly at specific intervals.
Tour 1-4
Tour Name:
Assign a name for the tour here.
Tour Position:
A position in a tour can be edited here.
Order:
Specify the order of a preset position within a tour here.
Select Pos.:
Select a saved preset position here.
Waiting time:
This value specifies the amount of time the pan/tilt head waits at a tour
position.
Set:
The tour parameter is transferred to the list below.
Clear:
Deletes a tour preset.
Clear All:
Deletes all presets in the tour.
Interval:
The tour can be made automatically at this interval (in hours). This is
activated via the “Set as default tour” point.
Set as default tour:
Sets the current tour as the default tour (the tour is started by pressing “Tour
Start”).
Accept the settings by pressing “OK” or cancel them by pressing “Cancel”.