68
69
GB
1 x Reinforced door bar
PR2800
1 x Cover for the
lock body
3
2 x End piece for the
cover
1
2
5
3 Sets Plastic
underlay
7
2 x Protective cap for
the lock case
2 x Lock case
6
10
4 x Dowel ø 6 mm
8
1 x Cylinder escut-
cheon for the outside
9
4 x Bridging cartridge
ø 6 mm
4 x Dowel ø 10 x 120 mm
4 x Screw 7 x 127 mm
11
12
14
13
4
2 x Screw-on plate
15
4 x Hexagon socket screw
M8 x 60 mm
17
16
1 x Masonry hole cover
4 x 8 x 4 x
ø 3,5 x ø 4 x ø 4,2 x
x 6,5 mm 3,5 mm 22 mm
1 x Door cylinder
(optional)
Thank you for choosing this ABUS product!
Please read this guide carefully before installation and use. Keep these instructions and provide all
users with instruction on how to use it. In case of a change in ownership, pass the instruction manual
to the new owner.
The ABUS reinforced door bar provides additional protection against unauthorised break-ins into
rooms. It is suitable for all standard doors made of wood, metal and plastic. Not all varieties of use
for the
PR2800
can be adressed with these fitting instructions. Ask a dealer if necessary.
The optimal protective effect is reached if you proceed according to these fitting and operating
instructions. The mounting screws should be tightened
manually
with a suitable tool to avoid over-
winding. Prior to fitting, you should ensure that the reinforced door bar is suitable for the structural
circumstances. The manufacturer disclaims all liability for any injury or damage caused during fitting
and/or by improper handling!
We recommend allowing a specially trained specialist installer to execute the fitting.
II. Package contents of the PR2800 in a standard design
(Fig. 1)
III. Field of application of the PR2800
The
PR2800
is suitable for all hinged and unhinged doors that open inwards and outwards,
DIN right or DIN left (Fig. 2). Doors with panelling and/or border trimmings must be individually
adjusted.
The standard design is suitable for doors opening inwards (door panel width of length 1:
735 mm to 980 mm or length 2: 980 to 1200 mm and door panel thicknesses of 33 to 48 mm).
Use spacer discs DS10 from a door panel thickness of 48 mm (table 1).
The
PR2800
can be fitted with a knob cylinder or a door half-cylinder (without the possibility of
closing from the outside).
The
PR2800
can also be equipped with different door cylinders following EN DIN 1303 / DIN 18252.
The proper functioning of the integrated protection to prevent the bolt from being pushed back
is only guaranteed when using a double profile cylinder without rotating cam with the key
removed.
VdS recognition
The VdS recognition only applies in connection with the use of a VdS class A or a higher class of
door cylinder. The reinforced door bar
PR2800
with VdS recognition is registered under the
number M 116306 VdS.
We recommend fitting beneath the mounting (Fig. 3).
The fitting of 2 pieces
PR2800
is recommended in the event of increased safety require ments.
One is then fitted above and below the mounting (Fig. 4).
The closing direction can be adjusted according to the door lock.
Fig. 2
DIN right
Hinged door
Hinge thickness
Hinge thickness
Unhinged door
DIN left
Door that opens inward
Door that opens outward
Содержание PR2800