3.4. Configuration parameters
Z-Wave products can be used directly after inclusion in the network. However, configuration settings
can be used to adapt the behaviour of the device even better to the requirements of the application and
to activate additional functions.
Use your Z-Wave controller to initiate the changes to the parameters. In order for the device to receive
the values, a wake-up must be performed on the device itself. (see point 2.5)
Para-
meter
Byte
size
Function
Default
value
Description
10
1
Threshold value
battery alarm
10
Percentage value from when the low battery
alarm should be transmitted.
Adjustable from
5 - 50
in percent
(Hexadecimal: 0x05 - 0x32)
12
1
PIR sensor
Active / Deactive
1
Enable / disable the PIR sensor.
0 = Sensor is deactivated
1 = Sensor is activated
(Hexadecimal: 0x00 - 0x01)
13
2
Waiting time between
two motion alarms
60
Waiting time from one motion alarm to the next
triggering.
Adjustable from 5 - 15300 in seconds
(Hexadecimal: 0x05 - 0x3BC4)
14
1
BASIC SET to
association group 2
(motion alarm)
0
BASIC SET should be sent after a motion
alarm.
0 = Disabled
1 = Active
(Hexadecimal: 0x00 - 0x01)
15
1
Invert value of BASIC
SET command
0
Set the value of the BASIC SET command for
movement alarm and acknowledgement.
0 = The motion alarm sends the BASIC
SET value "On" (0xFF), the
acknowledgement sends the BASIC SET
value "Off" (0x00)
1 = The motion alarm sends the BASIC
SET value "Off" (0x00), the
acknowledgement sends the BASIC SET
value "On" (0xFF)
(Hexadecimal: 0x00 - 0x01)
16
1
Sensitivity
PIR sensor
9
Sensitivity value of the PIR sensor.
The value 10 is the highest sensitivity.
The value 1 is the lowest sensitivity.
Adjustable from 1 - 10
(Hexadecimal: 0x01 - 0x0A)
17
1
Pet Immunity
Active / Deactive
0
Activate/deactivate the pet immunity.
0 = Pet immunity is deactivated
1 = Pet immunity is activated
(Hexadecimal: 0x00 - 0x01)