1.3.  Operating principle 

The device was developed for use in alarm and home automation systems that use the Z-Wave wireless 
standard. The device has the following functions: 

 

Motion detector

 

It uses Passive Infrared (PIR) technology to detect movement in a defined area by detecting the 
changes in thermal radiation caused by the moving body inside or outside the detection zone.  
When the motion detector is triggered, an alarm signal is sent to the Z-Wave controller and, after 
receiving the signal, the Z-Wave controller performs a specific action according to its settings. 
When motion is detected, the indicator LED lights up. 
The sensitivity & characteristics of the PIR sensor can be adjusted via the parameter settings so 
that the sensor hides pets up to approx. 38kg so that your pet can move freely without triggering 
the sensor. 

 

Integrated illuminance* sensor with separate day/night report 

The device automatically sends the measured brightness value and the day/night report to the 
Z-Wave controller or on request of the Z-Wave controller at periodic intervals. 
In addition, the brightness and day/night report is sent with each motion detection (default 
setting). You can adjust the lux threshold of the day/night report via parameter.  

 

*A photoconductive sensor is used to measure the illuminance (LUX). As this sensor can 
have  up  to  25%  error  tolerance  on  measured  values,  we  recommend  using  the  light 
values only to distinguish between day and night. 

 

 

Tamper protection between the device and wall bracket 

When the housing is opened, the sabotage switch is triggered and the device sends a sabotage 
alarm to the Z-Wave controller. 

 

1.4.  Performance features 

The device..: 

 

... is a battery-powered motion detector  

 

... is due to its design only suitable for wall mounting 

 

... is Z-Wave Plus compatible & certified 

 

... supports the Z-Wave S2 standard (Security 2) 

 

... has a low battery warning function 

 

... was developed for indoor installation 

 

1.5.  Use in systems of different manufacturers 

This product can be operated in any Z-Wave network with other Z-Wave certified devices from other 
manufacturers. All mains operated nodes within the network will act as repeaters regardless of vendor 
to increase reliability of the network. 

 

1.6.  DSK code 

The DSK code (Device-Specific Key) is the device-specific key of your device and is required for secure 
inclusion (teach-in) via S2 on the Z-Wave controller. The first 5 digits of the DSK code can be found on 
the QR Code on the back of the product. Please enter them in the inclusion process when prompted. 
Alternatively, you can transfer the entire DSK code that you find on the enclosed DSK card to the  Z-
Wave controller via QR Code Scan.  Please keep the DSK card in a safe place!

 

 

Hint:  

We recommend the secure S2 inclusion (must be supported by the Z-Wave controller) Please enter the 
5 digits of the DSK code (bottom of the device) or the entire DSK code (QR code) when prompted.

 

 

 

 

Содержание PLBW10100

Страница 1: ...PLBW10100 Nexello Motion Detector Important information and FAQs about this product and other products can be found on the website www abus com Manual version 1 2 Firmware version 1 58...

Страница 2: ...reuthweg 5 86444 Affing Germany E mail support abus sc com Phone 49 8207 959 90 0 Opening hours hotline Mon Thu 08 17 h Fri 08 14 h All contained company names and product names are trademarks of thei...

Страница 3: ...excessive dust For exact specifications check the technical data of the individual units Ensure that there is always sufficient ventilation that no direct heat sources act on the unit that no direct...

Страница 4: ...cleaned Dust deposits in the air slots can be sucked off or blown out If necessary the dust can be removed with a brush The surface can be cleaned with a cloth slightly moistened with soapy water Use...

Страница 5: ...rview 8 2 1 Inclusion teach in device 8 2 2 Planning assembly and installation 9 2 3 Exclusion teach out device 11 2 4 Resetting to factory settings 12 2 5 Wake up Waking up the device 12 2 6 Behaviou...

Страница 6: ...ignation Comment A Front cover Slided onto the holder B Fresnel Lens For motion detection C LED indicator Status display for various processes Inclusion exclusion reset error D Link Button Manual trig...

Страница 7: ...error tolerance on measured values we recommend using the light values only to distinguish between day and night Tamper protection between the device and wall bracket When the housing is opened the s...

Страница 8: ...r does not support SmartStart follow these instructions for Product Classic Inclusion Activate the inclusion mode teach in mode on the Z Wave controller for more details please refer to the Z Wave con...

Страница 9: ...set to 5 seconds each motion alarm is acknowledged after 5 seconds but to send a new motion alarm the motion detector must not have detected any motion for 5 seconds Use the test mode to select the o...

Страница 10: ...8m range and 80 angle of detection Use the bracket as a template to mark the position of two drill holes on the wall There are two markings each for wall and corner mounting Fix the bracket to the wal...

Страница 11: ...n Remove Exclusion in your Z Wave app and follow the instructions to set the Z Wave controller to Exclusion mode Press the Link button 3 times quickly within 1 5 seconds to start the exclusion on the...

Страница 12: ...ease use this procedure only if the primary network controller is missing or otherwise not functional If the device is set to factory default the status is set to not included and the association sett...

Страница 13: ...Only when the waiting time has elapsed without motion detection will the detector acknowledge the motion alarm and thus be able to send a motion alarm when a new motion is detected The standard waitin...

Страница 14: ...Group 1 5 Lifeline General notification report battery report Device Reset Locally Notification Sensor Multilevel Report Group 2 5 on off control Notification basic set Group 1 Association Z Wave Con...

Страница 15: ...Battery alarm replace soon 0x08 0x0A 0x00 Battery alarm replace now 0x08 0x0B 0x00 Battery alarm acknowledgement 0x08 0x00 0x01 0x0A 0x0B Light alarm day 0x14 0x01 0x00 Light alarm night 0x14 0x00 0x...

Страница 16: ...1 13 2 Waiting time between two motion alarms 60 Waiting time from one motion alarm to the next triggering Adjustable from 5 15300 in seconds Hexadecimal 0x05 0x3BC4 14 1 BASIC SET to association grou...

Страница 17: ...d classes Command class Version Association Version 2 Association Group Info Version 3 Battery Version 1 Configuration Version 4 Device Reset Locally Version 1 Firmware Update Md Version 5 Indicator V...

Страница 18: ...e of battery 1x CR123A Battery life 3 years Sabotage protection Yes Firmware updateable Yes OTA Z Wave manufacturer ID 0x0403 Z Wave Product Type ID 0x0002 Z Wave Device ID 0x0007 Z Wave SmartStart su...