3.4. Overview Configuration Parameters
Z-Wave products can be used directly after inclusion in the network. However, configuration settings
can be used to adapt the behaviour of the device even better to the requirements of the application and
to activate additional functions.
Para-
meter
Byte
size
Function
Default
value
Description
1
2
Alarm duration
180
Setting how long an alarm of the piezo siren
lasts when triggered.
Adjustable from 5 - 600 in seconds
(Hexadecimal: 0x05 - 0x258)
2
2
Alarm
0
Setting the reaction in case of an alarm.
0 = siren and LEDs / flash
1 = Siren only
2 = LEDs only / flash light
(Hexadecimal: 0x00 - 0x02)
3
2
Siren volume
0
Adjusts the volume of the siren.
0 = > 100dB
1 = > 85dB
(Hexadecimal: 0x00 - 0x01)
4
2
Sabotage Alarm
0
Defines whether an alarm should be triggered
directly in the event of a sabotage alarm.
0 = The siren does not automatically
trigger an alarm, the sabotage alarm is
triggered by the Z-Wave controller.
This function is deactivated by default,
because when activated, a sabotage
alarm is always triggered directly by the
siren, even if the Z-Wave controller/alarm
system is in maintenance mode, for
example.
1 = The siren always triggers an alarm
automatically, regardless of the status of
the Z-Wave controller.
Note:
Sabotage Alarm will also be triggered
while maintenance mode.
(Hexadecimal: 0x00 - 0x01)
5
2
Status display
0
Setting whether only certain status events
should be displayed.
0 = activation & deactivation
1 = Only activation
2 = Only deactivation
3 = No activation & deactivation
(Hexadecimal: 0x00 - 0x03)