3.4.  Overview Configuration Parameters 

Z-Wave products can be used directly after inclusion in the network. However, configuration settings 
can be used to adapt the behaviour of the device even better to the requirements of the application and 
to activate additional functions. 

 

Para-

meter 

Byte 

size 

Function 

Default 

value 

Description 

Alarm duration 

180 

Setting how long an alarm of the piezo siren 
lasts when triggered.  

 

Adjustable from 5 - 600 in seconds 

(Hexadecimal: 0x05 - 0x258) 

Alarm 

Setting the reaction in case of an alarm.  

 

0 = siren and LEDs / flash  

 

1 = Siren only 

 

2 = LEDs only / flash light 

 (Hexadecimal: 0x00 - 0x02) 

Siren volume 

Adjusts the volume of the siren. 

 

0 = > 100dB 

 

1 = > 85dB 

(Hexadecimal: 0x00 - 0x01) 

Sabotage Alarm 

Defines whether an alarm should be triggered 
directly in the event of a sabotage alarm.  

 

0 = The siren does not automatically 
trigger an alarm, the sabotage alarm is 
triggered by the Z-Wave controller.  
This function is deactivated by default, 
because when activated, a sabotage 
alarm is always triggered directly by the 
siren, even if the Z-Wave controller/alarm 
system is in maintenance mode, for 
example. 

 

1 = The siren always triggers an alarm 
automatically, regardless of the status of 
the Z-Wave controller.  
Note: 
Sabotage Alarm will also be triggered 
while maintenance mode. 

(Hexadecimal: 0x00 - 0x01) 

Status display 

Setting whether only certain status events 
should be displayed.  

 

0 = activation & deactivation 

 

1 = Only activation 

 

2 = Only deactivation 

 

3 = No activation & deactivation 

(Hexadecimal: 0x00 - 0x03) 

 

 

 

 

 

Содержание Nexello PLSG10100

Страница 1: ...PLSG10100 Nexello Outdoor siren Important notes and FAQs about this product and other products can be found on the website www abus com Manual version 1 0 Firmware version 1 01 ...

Страница 2: ...fing Germany E mail support abus sc com Phone 49 8207 959 90 0 Opening hours hotline Mon Thu 08 17 hrs Fri 08 14 hrs All company names and product designations contained herein are trademarks of their respective owners All rights reserved Disclaimer This operating manual has been prepared with the utmost care Should you nevertheless notice any omissions or inaccuracies please notify us in writing ...

Страница 3: ...vidual units Ensure that there is always sufficient ventilation that no direct heat sources act on the device that no direct sunlight or strong artificial light falls on devices for indoor use that the device is not in the immediate vicinity of magnetic fields e g loudspeakers that no open fire sources e g Do not stand on or next to the device avoid contact with splashing or dripping water on devi...

Страница 4: ...eaned Dust deposits in the air slots can be sucked off or blown out If necessary the dust can be removed with a brush The surface can be cleaned with a cloth slightly moistened with soapy water Use only suitable microfibre cloths for high gloss surfaces Make sure that no water gets inside the device Do not put the appliance in the dishwasher Do not use any sharp pointed abrasive caustic cleaning a...

Страница 5: ...2 Functional overview 8 2 1 Inclusion Teach in device 8 2 2 Planning assembly and installation 10 2 3 Exclusion teach in device 11 2 4 Reset to factory settings 11 2 5 System status 12 3 Advanced Z Wave Parameters 13 3 1 Association Groups 13 3 2 WakeUp Time 13 3 3 Reports 14 3 4 Overview Configuration Parameters 15 3 5 Supported command classes 16 3 6 Supported security levels 16 4 Technical data...

Страница 6: ...tive permanent power supply E Sabotage contact Triggers sabotage alarm the siren sends the sabotage alarm to the Z Wave controller If parameter 6 is set to the value 1 the siren triggers an alarm independently F Link Button Manual triggering of the wake up command inclusion exclusion and reset G Screw For locking the siren to the back plate H Backplate For mounting on the wall I Cable inlet To fee...

Страница 7: ...reas IP44 1 5 Use in systems of different manufacturers This product can be operated in any Z Wave network with other Z Wave certified devices from other manufacturers All mains operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network This product is based upon a slave Role Type implementing Security 2 with the Access Control Security Clas...

Страница 8: ...Wave controller s user manual Press the button Add Inclusion in your Z Wave app and follow the instructions to set the Z Wave controller into inclusion mode or The siren can be operated by batteries or mains adapter Pure battery operation The batteries are already inserted Simply connect the plug that comes from the battery compartment to the appropriate socket We recommend the exclusive use of th...

Страница 9: ...n 1 5 seconds to start the inclusion on the device Successful inclusion is displayed in the app or on the Z Wave controller and the status LED on the device stops flashing Repeat the inclusion process if it was not successful If a new attempt fails as well first carry out a factory reset on the device see 2 4 Lock the cover over the Link button and the LED display again with the three screws ...

Страница 10: ... outdoor use protection class IP44 Make sure that the siren is installed outside the hand area at a height of at least 3m Assembly instructions Use the bracket as a template to mark the position of two drill holes on the wall Fix the bracket to the wall using the plugs and screws provided First the upper drill holes J then the lower drill holes K for fixing and alignment Do not overtighten the scr...

Страница 11: ...xclusion on the device The successful exclusion is displayed in the app or on the Z Wave controller 2 4 Reset to factory settings Press the Link button 3 times quickly within 1 5 seconds Press quickly within 1 second a fourth time and hold down the Link Button for at least 5 seconds The siren is now reset to factory settings Hint This procedure should only be used if the primary network controller...

Страница 12: ...stem was deactivated Flashing 2 times briefly Beeps 2 al briefly in one second System has been activated Lights up for one second Beeps once for one second System was activated internally Lights up for one second Beeps once for one second Inevitability Lights up for 2 seconds Beeps 1 time long and 2 times short Invalid code Flashing 3 times briefly Beeps 3 times briefly ...

Страница 13: ...ices stored in an association group The device supports one association group Group Number Maximum Devices Group name Profile command class Group 1 5 Lifeline General notification report battery report Device Reset Locally Notification Switch Binary Report Group 1 Association Z Wave Controller The Lifeline Association is automatically established between the Z Wave controller and the device at inc...

Страница 14: ...3 0x00 Sabotage alarm Sabotage contact opened after it was closed for more than three seconds 0x07 0x03 0x00 Sabotage alarm acknowledgement sabotage contact is pressed for more than 3 seconds 0x07 0x00 0x01 0x03 battery report Value Description 0x14 0x64 20 100 Battery charge level in percent 0xFF 256 Low battery Switch Binary Report Shows the status of the siren s piezo alarm Value Description 0x...

Страница 15: ...me of the siren 0 100dB 1 85dB Hexadecimal 0x00 0x01 4 2 Sabotage Alarm 0 Defines whether an alarm should be triggered directly in the event of a sabotage alarm 0 The siren does not automatically trigger an alarm the sabotage alarm is triggered by the Z Wave controller This function is deactivated by default because when activated a sabotage alarm is always triggered directly by the siren even if ...

Страница 16: ... Update MD version 2 Indicator Manufacturer Specific version 2 Multi Channel Association version 2 Notification Version 4 Power level Security Security 2 Supervision Switch Binary Transport Service version 2 Version version 2 ZwavePlus Info version 2 3 6 Supported security levels Security S2 Authenticated Security S2 Unauthenticated Security S0 Authenticated ...

Страница 17: ...ansmitting power 5 dbm Power supply 9V DC Type of battery 4x LR14 C Battery life Approx 2 years Sabotage protection yes Firmware updateable Yes OTA Z Wave manufacturer ID 0x0403 Z Wave Product Type ID 0x0003 Z Wave Device ID 0x0006 Z Wave beaming supported Yes Z Wave SmartStart supported Yes Z Wave Plus supports Yes Z Wave Network Security Yes Z Wave AES 128 Security S0 Yes Z Wave S2 Security Yes ...

Отзывы: