Dimensions (WxHxD): 136 x 227 x 45mm
Weight
Housing 350g
PCBA 130g
Operating Temperatures: -10°C to +55°C
Environmental class II: (EN50131-1 §7, EN50131-3 §7)
Humidity: 0-93 % RH non-condensing
Protection class: IP30
Radio frequency: 868.6625 MHz
Radio Power: 10mW
Wireless Range: 500m outdoors
Wireless identification code: 16.777.214 (224 – 2) variants
Security level 2
(EN50131-1 §6, EN50131-3 §6)
When using external power supply of types A and B compliant with EN50131-1: 2006 + A1: 2009 + A2: 2017 §9.2
and EN50131-6: 2008 + A1: 2014
Tamper protection (detection/protection)
Type B (EN50131-3 §8.7)
Power supply: 9-15V DC
Power consumption: 35mA quiescent / 100mA max. (relay OP1-4 off)
Connections for external power supply
MAINS FAIL input. Connect to mains fail voltage free output on external PSU.
LOW BATT input. Connect to low batt voltage free output on external PSU.
0V 12V IN - Power supply connection
Number of voltage outputs: 4 - 0V 12V AUX up to 400mA total
Number of Relay outputs
4 - relay output potential-free, changeover contact NO / C / NC
1A @ 24 V AC rms or 30 V DC
Wired Zonen
10 (2-wire FSL/DEOL or 2-wire CC)
5 (4-wire CC)
Negative sabotage entrance
TR - The input is switched to the inactive low state (ground potential) through the connected siren.
The threshold voltage is active for> 4 V, for inactive <3.6 V.
Loudspeaker terminal
Min impedance 16 ohms
Max current in alarm 280mA
Conformity
is compliant with EN 50131-1, EN50131-3: 2009, EN50131-5-3 and EN50131-6
Security level 2 when properly installed in conjunction with the Secvest wireless alarm system FUAA50xxx.
EU Directives
RED: 2014/53/EU
RoHS: 2011/65/EU
WEEE: 2012/19/EU