35
AZWG10000
8.4.1 Voice
messages
Using the AZ6451 voice module, 4 individual voice texts (at 10 seconds each) can
be recorded and sent (via GSM) to defined contacts in the event of an alarm.
8.4.2 SMS
text
The device can send predefined messages to contacts.
IMPORTANT:
The text messages (SMS) for triggering the inputs can be defined individually. The
text messages (SMS) specified below show the default texts only!
Event
Description
Text message (SMS)
Trigger
Input 1-4
A message is transmitted if an
input is triggered.
Input 1: “Intruder Alarm”
Input 2: “Panic Alarm”
Input 3: “Fire Alarm”
Input 4: “Emergency Alarm”
Reset
Input 1-4
A message is transmitted if an
input trigger is reset.
Input 1: “Intruder Restore”
Input 2: “Panic Restore”
Input 3: “Fire Restore”
Input 4: “Emergency Restore”
Tamper
A message is transmitted if the
cover or wall contact is triggered.
“GSM box tamper”
Reset
Tamper
A message is transmitted if the
tamper state is is reset.
“GSM box tamper OK”
Fault
PSTN
A message is transmitted if the
analogue telephone line fails.
The message is transmitted
following timeout of the period
set for “PSTN Loss Delay”.
“Line fault”
Reset
PSTN
A message is sent when the
analogue telephone line is
working again.
“ Phone Line OK”
Reset
GSM
A message is sent when the
GSM network is stable again.
“GSM line OK”
Fault
Mains supply
voltage
A message is sent if the mains
power supply fails. The message
is transmitted following timeout of
the period set for “AC Loss
Delay”.
“Mains loss”
Reset
Mains supply
voltage
A message is sent when the
mains power supply is resumed.
“Mains power OK”
Battery fault
A message is sent if the battery
is missing or of the voltage falls
below 11 V DC.
“GSM low battery”