Absolent Air Care Filtermist FX Series Скачать руководство пользователя страница 4

4

Please note that units intended for use in countries outside Britain may require changes to the 
motor settings. Please contact Filtermist 

-JNJUFE

 (01952 290500) for advice and technical support.

To ensure the continued performance of your Filtermist system, there is an integrated log book that the operator 
must complete. The forms included in this book should be used to record these checks, together with comments 
on any corrective action. Also a section for regular maintenance and unplanned repair work should be completed 
and is included in the log book. Any failure that is found should be reported to the person responsible for the 
maintenance of the system. The log book can be found from page 21 in this manual. It is important that these 
records are kept up to date to provide evidence that the system is following the HSE guidelines and that it is 
operating correctly.

2

.

g

i

F

1

.

g

i

F

Installation

A Filtermist unit is normally sited either on (e.g. Fig.1) or close to the application, mounted on a stand (e.g. 
Fig.2) and therefore installation is straightforward requiring minimal ductwork. Filtermist units are light, 
require minimal floor space and can be installed in a wide variety of ways. A comprehensive library of existing 
installations is held by the company and can be used to demonstrate typical installations on most machine tools 
and applications.

Mounting the Unit

The following are typical installations and cover the majority of applications. For more advice on these or other
installation methods please contact your local supplier.

Always try to position the extraction point as far as practically possible from the cutting area of the machine and
so that mist is drawn away from the operator’s working area. On installation always take into account access and 
space requirements for service and maintenance of the unit, including consideration of local health and safety 
regulations. For ease of access, where possible,  the unit should be positioned between 1040mm and 1370mm 
above the working level (providing the efficiency of the unit isn’t compromised).

Содержание Filtermist FX Series

Страница 1: ...odels S200 S400 S800 FX4002 FX5002 FX6002 FX7002 Local Exhaust Ventilation Manual Log Book Principles Installation Maintenance and Testing of Filtermist LEV Systems Company Unit Model No Unit Serial N...

Страница 2: ...re at suitable test points indicated in the system documentation Observe processes and sources and assess how effective the LEV is at controlling operators exposure When testing hoods the examiner wil...

Страница 3: ...ss A perforated steel drum open at one end is directly driven by a 3 phase electric motor Four vanes within the drum generate suction which draws aerosols into the drum Here the aerosols are impacted...

Страница 4: ...y sited either on e g Fig 1 or close to the application mounted on a stand e g Fig 2 and therefore installation is straightforward requiring minimal ductwork Filtermist units are light require minimal...

Страница 5: ...st units remove and separate contaminants by centrifugal impaction forcing aerosols to coalesce into larger droplets and removing them from the airstream High levels of ltration and constant ef ciency...

Страница 6: ...be from the Filtermist unit should be straight with smooth bends no kinks and unrestricted e g Fig 5 The end of the tube must not be submerged as this will prevent oil from the unit being discharged F...

Страница 7: ...t see table 1 on page 12 t i n u h t i w d e i l p p u s s d u t s e s a c x 4 t i F 2 t i n u f o e s a b n i s w e r c s t r e s n i x 4 e v o m e R 1 3 Fit foam collar seal around inlet spigot supp...

Страница 8: ...re 3 Connect inlet of unit to extraction hole using suitable duct and adaptor supplied separately 4 Fit oil return tube and position tube to drain oil back to machine enclosure sump or collection vess...

Страница 9: ...T 3 inside of unit IMPORTANT There must be no kinks or U bends in the return tube The end of the tube must not be submerged 5 Position unit in stand and secure unit with bolts supplied with unit 6 Co...

Страница 10: ...ional equipment The F Monitor is a monitoring device that measures air ow and time to indicate when the ltermist unit needs servicing An additional sensor can be tted to also monitor temperature and v...

Страница 11: ...with the machine cycle Recommended overload settings and terminal connection Overloads to be set no higher than 125 of the motors full load current IMPORTANT Please note that for 230 240v 50HZ applic...

Страница 12: ...0mm 155mm 155mm 155mm 205mm 205mm 205mm Case Stud Hole PCD mm 190 250 5 7 2 5 7 2 5 7 2 5 7 2 0 5 2 Case Stud Hole Diameter mm 10 10 0 1 0 1 0 1 0 1 0 1 Drain Tube Diameter 19mm 19mm 19mm 19mm 19mm 19...

Страница 13: ...he log book provided with each unit EEJUJPOBM DPQJFT DBO CF SFRVFTUFE CZ DPOUBDUJOH PVS PGGJDF Maintenance requirements are covered by two schedules 1000 hour Service Parts required for the 1000 hour...

Страница 14: ...ide of drum and inspect drum for signs of damage IMPORTANT Damaged drums should be replaced 6 Fit new drum pads t i n u e l b m e s s a e R 9 r a e l c s i e l l i r g t e l n i k c e h C 8 l a e s w...

Страница 15: ...p m u r d d l o e v o m e R 6 m u r d e v o m e R 5 s t u n g n i t n u o m r o t o m e v o m e R 9 s d a p m u r d w e n t i F 8 m u r d f o e d i s t u o d n a e d i s n i n a e l C 7 12 Remove old...

Страница 16: ...bolts t i n u e l b m e s s a e R 8 1 r a e l c s i e l l i r g t e l n i k c e h C 7 1 l a e s w e n t i F 6 1 IMPORTANT Ensure safety latch and clip are securely fastened Every 2000 Hours Running Ti...

Страница 17: ...hould be checked and cleaned on a more frequent basis according to duty Contact your FILTERMIST supplier for details of maintenance plans and spares kits IMPORTANT Use only genuine Filtermist spares U...

Страница 18: ...cy Afterfilter 99 95 efficiency S200 S400 S800 S200 S400 S800 20 206 10 000 20 206 10 003 20 206 10 003 No HE Afterfilter for the S200 20 206 10 006 20 206 10 006 4 For 1000 hour service S200 Filter K...

Страница 19: ...0 019 3 4 For 1000 hour service 2 0 0 4 X F t i K r e t l i F FX5002 FX6 7002 20 213 30 047 20 213 30 048 20 213 30 049 5 For 2000 hour service 2 0 0 4 X F t i K s e r a p S FX5002 FX6 7002 20 213 30...

Страница 20: ...t Drum is rotating in wrong direction Drain hose is blocked kinked or sub merged Excessive extraction Mist could be oil smoke Check rotation of drum anti clockwise when viewed from inlet Re position a...

Страница 21: ...21 21 Local Exhaust Ventilation LOG BOOK...

Страница 22: ...erational Once the unit is running check the status of the air ow monitor if tted Weekly Checks Check all grilles and pre lters within the extraction ductwork and ensure they are clear Check that the...

Страница 23: ...5 anni e per scaricare termini e condizioni Visite www filtermist es para activar su garant a de 5 a os y descargar los t rminos y condiciones All new Filtermist oil mist filters come with a FREE Y E...

Страница 24: ...24 Daily Log Sheet s t n e m m o C d e n g i S S S F T W T M k e e W Daily Log Sheet...

Страница 25: ...25 Daily Log Sheet s t n e m m o C d e n g i S S S F T W T M k e e W Daily Log Sheet...

Страница 26: ...26 Daily Log Sheet s t n e m m o C d e n g i S S S F T W T M k e e W Daily Log Sheet...

Страница 27: ...27 Daily Log Sheet s t n e m m o C d e n g i S S S F T W T M k e e W Daily Log Sheet...

Страница 28: ...28 Daily Log Sheet s t n e m m o C d e n g i S S S F T W T M k e e W Daily Log Sheet...

Страница 29: ...29 Weekly Log Sheet s t n e m m o C d e n g i S 4 k c e h C 3 k c e h C 2 k c e h C 1 k c e h C k e e W Weekly Log Sheet...

Страница 30: ...30 Weekly Log Sheet s t n e m m o C d e n g i S 4 k c e h C 3 k c e h C 2 k c e h C 1 k c e h C k e e W Weekly Log Sheet...

Страница 31: ...31 Weekly Log Sheet s t n e m m o C d e n g i S 4 k c e h C 3 k c e h C 2 k c e h C 1 k c e h C k e e W Weekly Log Sheet...

Страница 32: ...32 Monthly Log Sheet Month Check 1 Check 2 Check 3 Check 4 Check 5 Check 6 s t n e m m o C d e n g i S Monthly Log Sheet Statutory LEV Testing is now due...

Страница 33: ...rs Full Service Date Signed by 2000hrs Full Service Date Signed by 2000hrs Full Service Date Signed by 2000hrs Interim Service Date Signed by 1000hrs Unscheduled Maintenance Repair Date Reason for Mai...

Страница 34: ...010 EN 60204 1 2018 EN ISO 14120 2015 EN ISO 13857 2019 The technical file is compiled in accordance with part A of Annex VII of the Machinery Directive 2006 42 EC Person authorised to compile the tec...

Страница 35: ...35 1st January 2023 Filtermist Limited Telford 54 Business Park Nedge Hill Telford TF3 3AL England Filtermist Limited Telford 54 Business Park Nedge Hill Telford TF3 3AL England...

Страница 36: ...Filtermist Limited Telford 54 Business Park Nedge Hill Telford Shropshire TF3 3AL England 5FM NBJM TBMFT GJMUFSNJTU DPN XXX GJMUFSNJTU DPN Supplied by 20 218 10 033 Rev1 QSJM 2023...