![Absolent Air Care Filtermist FX Series Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/absolent-air-care/filtermist-fx-series/filtermist-fx-series_user-manual-and-log-book_3513663011.webp)
11
Electrical Connection
Filtermist FX series and S Series motors are wound for low & high voltage and operate on 50Hz & 60Hz as shown
in the table below. A connection diagram can be found inside the motor terminal box.
NOTE:
Motor terminal connections will be configured for the motor to run at High voltage unless Low voltage
connection is specified at the time of ordering.
The motors must be connected via a 3-phase, direct-on-line starter and isolator with suitable thermal overloads
or via an independent supply in the machine control panel.
On start-up the motor will draw current in excess of that shown on the motor plate. Ensure that appropriate
fuses are used.
IMPORTANT!
The unit must run in the direction indicated by the arrow on the upper section and must run
continuously. To change rotation, swap any two supply wires. It must not be wired to switch on and off with the
machine cycle.
Recommended overload settings and terminal connection. Overloads
to be set no higher than 125% of the motors full load
current.
IMPORTANT!
Please note that for 230/240v, 50HZ applications, special motors are required. For more
information, contact your supplier
IMPORTANT!
FX7002 must only be used with 50HZ supply.
Do not use on 60HZ APPLICATIONS
L1
L2
L3
U2
W2
V2
V1
U1
W1
0.18kw (6 pin)
L1
L2
L3
U2
W2
V2
V1
W1
0.18kw (6 pin)
U1
L1
L2
L3
W2
V2
U2
V5
W5
U5
V1
W1
U1
L1
L2
L3
W2
V2
U2
V5
W5
U5
V1
W1
U1
Electrical Connection
Low Voltage Settings
LOW
VOLTAGE
recommended overload settings
200v
220v
230v
50hz
60hz
50hz
60hz
60hz
0.18kw
FLC
1.02
1.02
1.02
1.02
1.02
0.55kw
FLC
2.7
2.6
2.7
2.6
2.6
1.1kw
FLC
4.4
4.6
4.4
4.6
4.6
1.5kw
FLC
6.3
6.3
6.3
6.3
6.3
2.2kw
FLC
8.8
9.4
8.8
9.4
9.4
High Voltage Settings
HIGH
VOLTAGE
recommended overload settings
380v
400v
440v
460v
480v
575v
50hz
50hz
60hz
60hz
60hz
60hz
0.18kw
FLC
*
0.55kw
FLC
1.35
1.35
1.3
1.3
1.3
*
1.1kw
FLC
2.2
2.2
2.3
2.3
2.3
*
1.5kw
FLC
3.15
3.15
3.15
3.15
3.15
*
2.2kw*
FLC
4.4
4.4
4.7
4.7
4.7
*
Содержание Filtermist FX Series
Страница 21: ...21 21 Local Exhaust Ventilation LOG BOOK...
Страница 24: ...24 Daily Log Sheet s t n e m m o C d e n g i S S S F T W T M k e e W Daily Log Sheet...
Страница 25: ...25 Daily Log Sheet s t n e m m o C d e n g i S S S F T W T M k e e W Daily Log Sheet...
Страница 26: ...26 Daily Log Sheet s t n e m m o C d e n g i S S S F T W T M k e e W Daily Log Sheet...
Страница 27: ...27 Daily Log Sheet s t n e m m o C d e n g i S S S F T W T M k e e W Daily Log Sheet...
Страница 28: ...28 Daily Log Sheet s t n e m m o C d e n g i S S S F T W T M k e e W Daily Log Sheet...