ABS Piranha submersible grinder pump S10 - PE125

10 

Troubleshooting Guide

Fault

  

Cause

 

Fix

Pump does not 
run  

Moisture sensor shutdown.

Check for loose or damaged oil plug, or locate and 
replace faulty mechanical seal / damaged o-rings. 
Change oil.

1)

Level control override.

Check for float switch that is faulty or tangled and 
held in OFF position in sump.

Impeller jammed.

Inspect and remove jammed object. Check gap 
between impeller and bottom plate and adjust if 
necessary.

Gate valve closed, non-return valve 
blocked.

Open gate valve, clean blockage from non-return 
valve.

Pump switching on/off
intermittently

Temperature sensor shutdown.

Motor will restart automatically when pump cools 
down. 
Check thermal relay settings in control panel.
Check for impeller blockage. 
If none of above, a service inspection is required.

1)

Low head or flow

Wrong direction of rotation.

Change rotation by interchanging two phases of 
the power supply cable.

Gap too wide between impeller and 
bottom plate

Reduce gap.

Gate valve partially open.

Open valve fully.

Excessive noise or 
vibration

Defective bearing.

Replace bearing.

1)

Clogged impeller.

Remove and clean hydraulics.

Wrong direction of rotation.

Change rotation by interchanging two phases of 
the power supply cable.

High voltage

Water inside motor.

Replace stator.

1)

test failure

Stator insulation damaged.

Replace stator.

1)

Power cable or lead damaged.

Replace power cable.

1)

Ohms test 
failure 

Stator failure.

Repair/replace stator.

1)

 

Before commencing any inspection or repair work the pump should be completely disconnected from 
the mains by a qualified person and care should be taken that it cannot be inadvertently switched back 
on.

1) 

Pump must be taken to approved workshop.

 

 

Содержание Piranha S10/4W-50

Страница 1: ...www cardo com ABS Piranha submersible grinder pump S10 PE125 01 2011 GB Installation Operating and Maintenance Instructions...

Страница 2: ...f approval 3 Safety 3 2 1 Use of explosion proof pumps in explosive zones 3 2 2 Special conditions for safe use of S type explosion proof motors 3 3 Technical data 4 3 1 Nameplate 4 4 General design f...

Страница 3: ...ns as to safety make certain to contact the manufacturer ABS 1 Use of explosion proof pumps in explosive zones Explosion proof submersible pumps may only be operated with the thermal sensing system co...

Страница 4: ...locations and the Ex nameplate must be removed Standard nameplate Cardo Production Wexford Ltd Wexford Ireland www cardo com Typ Nr Sn xx xxxx UN IN Ph Hz P1 P2 1 min Cos NEMA IP68 Qmax Hmax Imp DN Hm...

Страница 5: ...r chamber pressure test point 6 Stainless steel shaft 7 Lower bearing double row 8 Oil lubricated lip seal 9 Bearing housing 10 Volute 1 Cast iron lifting handle and steel shackle 2 Upper bearing sing...

Страница 6: ...le terminal block 4 Moisture sensor Di 5 Oil chamber 6 Oil chamber drain plug pressure test point 7 Stainless steel lifting hoop 8 Upper bearing single row 9 Motor with thermal sensors 10 Stainless st...

Страница 7: ...the pump is being taken out of service the oil should be changed before storage After storage the pump should be inspected for damage the oil level should be checked and the impeller checked to ensur...

Страница 8: ...uit the pump performance 6 1 Installation example in concrete sump 1 Sump cover 1005 00 2 Venting line 3 Sump cover 4 Protective duct to the control panel for cable 5 Chain 6 Inflow line 7 Ball type f...

Страница 9: ...elevant safety regulations as well as general good technical practice must be complied with ATTENTION For use in the open air the following VDE regulations apply Submersible pumps used outdoors must b...

Страница 10: ...E70 2E Ex PE90 2E Ex PE110 2E Ex Piranha 60 Hz S10 4 S10 4 Ex S20 2 S20 2 Ex S26 2 S26 2 Ex PE25 2C Ex PE35 2C Ex PE45 2C Ex S10 4 S10 4 Ex S20 2 S20 2 Ex S30 2 S30 2 Ex PE28 2C Ex PE35 2C Ex PE45 2C...

Страница 11: ...o the direction of rotation ATTENTION When viewed from above the direction of rotation is correct if the impeller rotates in a clockwise manner NOTE The start reaction is anti clockwise NOTE If a numb...

Страница 12: ...well as good general technical pratices should be followed NOTE The maintenance instructions given here are not designed for do it yourself repairs as special technical knowledge is required 9 1 Gener...

Страница 13: ...of water into the oil chamber or motor chamber after repair work that requires draining of the oil if the pump is being taken out of service the oil should be changed before storage 9 3 1 Instruction...

Страница 14: ...ent blocks every six months in a single family home once a year In addition we recommend that a maintenance contract be taken out with a qualified company 9 7 Cleaning If the pump is used for transpor...

Страница 15: ...ngs in control panel Check for impeller blockage If none of above a service inspection is required 1 Low head or flow Wrong direction of rotation Change rotation by interchanging two phases of the pow...

Страница 16: ...re in conformity with the following standards or other normative documents as defined by Machinery Directive 006 4 EC EMC Directive 004 108 EC Low Voltage Directive 006 95 EC ATEX 94 9 EC Construction...

Страница 17: ...SERVICE LOG Pump Type Serial No Date Hours of Opera tion Comments Sign...

Страница 18: ...SERVICE LOG Date Hours of Opera tion Comments Sign...

Страница 19: ...SERVICE LOG Date Hours of Operation Comments Sign...

Страница 20: ...Cardo Production Wexford Ltd Clonard Road Wexford Ireland Tel 353 53 91 63 200 Fax 353 53 91 42335 www cardo com...

Отзывы: