Installation, Operating and Maintenance Instructions (Original Instructions)

ABS Piranha submersible grinder pump S10 - PE125

Technical data

Maximum noise level ≤ 70dB. This may be exceeded in certain circumstances.

Detailed technical information is available in the technical data sheet ABS Piranha submersible grinder pump 08 
- 125 which can be downloaded from www.absgroup.com > Downloads.

3�1 

Nameplate

We recommend that you record the data from the nameplate on the pump in the corresponding form below, and 
maintain it as a source of reference for the ordering of spare parts, repeat orders and general queries. 

Always state the pump type, item no. and serial no. in all communications.

Piranha-PE pumps are rated for use in hazardous locations (Ex) as standard, and are fitted with a standard 
nameplate containing technical data and a secondary nameplate to certify that the pump is Ex rated (examples 
below).
If a Piranha-PE pump is serviced or repaired in a workshop that is not Ex approved then it must no longer be 
used in hazardous locations and the Ex nameplate must be removed.

                                                                                                                                                                                 

Standard nameplate

Cardo Production Wexford Ltd.
Wexford, Ireland
www.cardo.com

           

Typ
Nr                                           Sn                                  xx/xxxx
            U

N

                              I

N

                                    Ph         Hz

            P1:                             P2:                                              1/min
Cos φ                                     NEMA                                         IP68
Qmax                                     Hmax                                   ØImp
DN                                         Hmin                              Weight 
           EN 12050-1                                                                                       

         

 

 

Piranha-S

                                                               

Piranha-PE

                            

Ex nameplate

                   

                                                                                                                                                                

                                                                                                               Piranha-PE

 

 

Piranha-S 

 

 

 

 

   

Legend

Typ

Pump type

Nr

Item No.

Sn

Serial No.

xx/xxxx

Production date (Week/Year)

U

N

Rated voltage

V

I

N

Rated current

A

Ph

Number of phases

Hz

Frequency

Hz

P1

Rated input power

kW

P2

Rated output power

kW

Legend

Typ

Pump type

Nr

Item No.

Sn

Serial No.

xx/xxxx

Production date (Week/Year)

U

N

Rated voltage

V

I

N

Rated current

A

Ph

Number of phases

Hz

Frequency

Hz

P1

Rated input power

kW

P2

Rated output power

kW

1/min

Speed

r/min

Cos φ

Power factor

pf

NEMA

NEMA code

Qmax

Max. Flow

m3/h

Hmax

Max. Head

m

Ø Imp.

Impeller diameter

mm

DN

Discharge diameter

mm

1/min

Speed

r/min

Cos φ

Power factor

pf

NEMA

NEMA code

Qmax

Max. Flow

m3/h

Hmax

Max. Head

m

Ø Imp.

Impeller diameter

mm

DN

Discharge diameter

mm

Cardo Production Wexford Ltd.
Wexford, Ireland
www.cardo.com

Cardo Production Wexford Ltd.
Wexford, Ireland
www.cardo.com

2G k Ex d

B T4

0102

Do not open while energized
Nicht unter Spannung öffnen

2G k Ex d

B T4

0102

Do not open while energized
Nicht unter Spannung öffnen

Содержание Piranha S10/4W-50

Страница 1: ...www cardo com ABS Piranha submersible grinder pump S10 PE125 01 2011 GB Installation Operating and Maintenance Instructions...

Страница 2: ...f approval 3 Safety 3 2 1 Use of explosion proof pumps in explosive zones 3 2 2 Special conditions for safe use of S type explosion proof motors 3 3 Technical data 4 3 1 Nameplate 4 4 General design f...

Страница 3: ...ns as to safety make certain to contact the manufacturer ABS 1 Use of explosion proof pumps in explosive zones Explosion proof submersible pumps may only be operated with the thermal sensing system co...

Страница 4: ...locations and the Ex nameplate must be removed Standard nameplate Cardo Production Wexford Ltd Wexford Ireland www cardo com Typ Nr Sn xx xxxx UN IN Ph Hz P1 P2 1 min Cos NEMA IP68 Qmax Hmax Imp DN Hm...

Страница 5: ...r chamber pressure test point 6 Stainless steel shaft 7 Lower bearing double row 8 Oil lubricated lip seal 9 Bearing housing 10 Volute 1 Cast iron lifting handle and steel shackle 2 Upper bearing sing...

Страница 6: ...le terminal block 4 Moisture sensor Di 5 Oil chamber 6 Oil chamber drain plug pressure test point 7 Stainless steel lifting hoop 8 Upper bearing single row 9 Motor with thermal sensors 10 Stainless st...

Страница 7: ...the pump is being taken out of service the oil should be changed before storage After storage the pump should be inspected for damage the oil level should be checked and the impeller checked to ensur...

Страница 8: ...uit the pump performance 6 1 Installation example in concrete sump 1 Sump cover 1005 00 2 Venting line 3 Sump cover 4 Protective duct to the control panel for cable 5 Chain 6 Inflow line 7 Ball type f...

Страница 9: ...elevant safety regulations as well as general good technical practice must be complied with ATTENTION For use in the open air the following VDE regulations apply Submersible pumps used outdoors must b...

Страница 10: ...E70 2E Ex PE90 2E Ex PE110 2E Ex Piranha 60 Hz S10 4 S10 4 Ex S20 2 S20 2 Ex S26 2 S26 2 Ex PE25 2C Ex PE35 2C Ex PE45 2C Ex S10 4 S10 4 Ex S20 2 S20 2 Ex S30 2 S30 2 Ex PE28 2C Ex PE35 2C Ex PE45 2C...

Страница 11: ...o the direction of rotation ATTENTION When viewed from above the direction of rotation is correct if the impeller rotates in a clockwise manner NOTE The start reaction is anti clockwise NOTE If a numb...

Страница 12: ...well as good general technical pratices should be followed NOTE The maintenance instructions given here are not designed for do it yourself repairs as special technical knowledge is required 9 1 Gener...

Страница 13: ...of water into the oil chamber or motor chamber after repair work that requires draining of the oil if the pump is being taken out of service the oil should be changed before storage 9 3 1 Instruction...

Страница 14: ...ent blocks every six months in a single family home once a year In addition we recommend that a maintenance contract be taken out with a qualified company 9 7 Cleaning If the pump is used for transpor...

Страница 15: ...ngs in control panel Check for impeller blockage If none of above a service inspection is required 1 Low head or flow Wrong direction of rotation Change rotation by interchanging two phases of the pow...

Страница 16: ...re in conformity with the following standards or other normative documents as defined by Machinery Directive 006 4 EC EMC Directive 004 108 EC Low Voltage Directive 006 95 EC ATEX 94 9 EC Construction...

Страница 17: ...SERVICE LOG Pump Type Serial No Date Hours of Opera tion Comments Sign...

Страница 18: ...SERVICE LOG Date Hours of Opera tion Comments Sign...

Страница 19: ...SERVICE LOG Date Hours of Operation Comments Sign...

Страница 20: ...Cardo Production Wexford Ltd Clonard Road Wexford Ireland Tel 353 53 91 63 200 Fax 353 53 91 42335 www cardo com...

Отзывы: