![ABNOX MURALT AX-III Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/abnox/muralt-ax-iii/muralt-ax-iii_instruction-manual_3453318023.webp)
EN
23
Fault Localisation, Troubleshooting
Fault
Possible cause
Corrective action
No pumping of grease
Grease reservoir is empty
Refill the reservoir.
Air pockets
Open the bleed valve
and operate the lever
until grease comes out
constantly. Then close
the air bleed valve.
No pressure
Contamination
Clean the press head
(intake/discharge valve).
Training of Personnel
Only trained and instructed personnel who have read and understood all points of the
Operating Manual may work on the product. Likewise the individual operating states
must be mastered, and the related safe aspects must be known and they must be
able to implement them. Personnel undergoing training may only work on the product
under the supervision of qualified personnel.
Customer Service/Support
ABNOX AG
Langackerstrasse 25
CH-6330 Cham
Switzerland
Tel.
+41 (0) 41 780 44 55
Fax
+41 (0) 41 780 44 50
Internet
www.abnox.com
CAUTION
Remediation of any of the faults described below may only be carried out
by a trained technician.