Operation
Filling
With dispensing system:
1. With the filler neck (Figure C/No.3), press the grease pump against the
medium discharge (Figure C/No.11) of the dispensing system.
2. Fill the pump with even pumping movements (Figure D/No. 12). When the
dispensing system cannot be pumped any more, the grease pump is full.
3. Remove the grease pump from the dispensing system.
4. Open the air bleed valve (Figure A/No.6). Once grease comes out constantly,
close the air bleed valve again.
5. Slide the chain back into the cylinder.
NOTE
Avoid filling by hand if possible.
This can lead to air pockets and therefore malfunctions.
DANGER
Filling with high-pressure lubrication systems is prohibited due to the
risk of bursting. This could lead to severe damage to property, serious
physical injuries or death.