23
en
Technical Data
Assembly/Installation
The product is to be set up or installed at the inten-
ded use site under due consideration of the following
conditions:
• At the location and site all applicable provisions of
law must be clarified and compliance with them
assured.
• The ground and space relations are to be clarified
prior to set-up/installation of the product in order
to assure safe operation for the personnel and the
product long-term. The product must be set-up/
installed so that safe, permanent operation is
assured.
• The product may only be set up and commissioned
by specially trained technicians.
• The product is constructed for rooms that are
protected from the influence of the weather
(industry standard).
• The operation and storage in aggressive or humid
environments or outdoors can lead to corrosion
damages.
Container
25 kg
25 kg
Model
AXFP2-S25-Slim
AXFP2-S60-Slim
Pressure ratio
25:1
60:1
Delivery volume at pump output (cm
3
/min)
1,500
700
Connection (medium) external thread
Figure C/no. 9
G ¼
"
G ¼"
Connection (compressed air) internal thread
Figure C/no. 8
G ¼"
G ¼"
Pump model
Type S
Type S
Container height max. (mm)
430
430
Inner container diameter min./max (mm)
175-410
175-410
Output pressure (medium) at 6 bar working pressure (bar)
150
360
Output pressure (medium) at 10 bar working pressure (bar) 250
600
Min./max. input working pressure (bar)
4/10
4/10
Max. air consumption (l/min)
180
180
Conveying volume per double stroke (cm
3
)
31
13
Содержание AXFP-Slim
Страница 2: ...2 A C E B D F C 1 5 3 4 F 6 7 2 9 2 24 8 10 11 12 5 15 14 13 4...
Страница 3: ...3 G I H J K 16 21 22 17 19 20 18 23 22...
Страница 6: ...6...
Страница 18: ...18...
Страница 30: ...30...
Страница 42: ...42...
Страница 54: ...54...
Страница 66: ...66...
Страница 78: ...78...
Страница 90: ...90...
Страница 102: ...102...
Страница 114: ...114...