
|
Mechanical and electrical installation
22
10
Use the toggle key
to select the appropriate
baud rate and hold the enter key
for about 3 sec-
onds to confirm.
y
Calibration law compliant Controller charging
station:
Select the value
9,600
y
Calibration law non-compliant controller
charging station:
Select the value
38,400
≤1S
≥3S
11
Use the toggle key
to select the
PAritY
menu for
the parity of the energy meter and briefly press the
enter key
.
≤1S
≤1S
12
Use the toggle key
to select the parity
EVEN
and hold the enter key
for about 3 seconds to
confirm.
≤1S
≥3S
13
Use the toggle key
to select the
bStoP
menu for
the stop bit of the energy meter and briefly press the
enter key
.
≤1S
≤1S
14
Use the toggle key
to select the value
1
for the
stop bit and hold the enter key
for about 3 sec-
onds to confirm.
≤1S
≥3S
15
Use the toggle key
to select
End
and briefly
press the enter key
.
≤1S
≤1S
The energy meter is now set up for operation as a load management system for a group installation. The next step is
to set up the individual charging stations and the group in the
ABL Configuration Software
and
ABL User Inter-
face
applications.