EN 19 Installation
1. Carefully unpack all components and
7. Do not use extension cables to
check them on possible damage.
connect the appliance.
2. Before putting the appliance into use,
8. This appliance may not be placed
it must be fully finished and installed in
above a dishwasher or tumble dryer: the
a kitchen environment and in a suitable
steam may damage the electrical
worktop material.
system and may lead to dangerous
3. This appliance is only for the
situations.
domestic preparation of food. Any other
use is prohibited.
4. Remove before use all labels and
Important: This appliance
stickers which are on the ceramic glass
needs sufficient ventilaton.
induction plates.
Consider this during the installation;
5. The induction zones and control panel
make sure that the ventilation
may not be used as working or storage
apertures are in line with the air
tops.
supply apertures in the cabinet.
6. The appliance must be earthed and
After building the appliance in, it must
connected in accordance with the local
be secured that parts which are under
regulations.
electrical tension, cannot be touched.
!
20mm min
50mm min
removable
55mm min
20mm min
50mm min
removable
Make sure during installation and use, that
there is no tensile stress on components
and wires.
The required wiring diagram are printed on
the stickers on both the wires as the
power unit.
Installation to the electrical network must
be done with earthed power plugs.
A fuse must always be placed between
the appliance and the electrical network
like a earth leakage circuit breaker, fuse or
stop.
Installation of the cooking zones
Installation example
For the various installation methods, use
the brass connectors whic are placed in
the power unit.
Attention!
Always connect the earth wire.
Act in accordance with the wiring
diagram, which can be found on the power
unit.
This appliance can only be used on a
230V
~
50Hz electricity network.
De electrical connections of the power
unit are on the underside, at the rear. Use a
screwdriver to open the clip of the lid.
7
7
C
5
5
5-6-7-8
5
c
5
5-6-7-8
Country
electrical tension connection
wire diameter
fuse
NL
230V
~
50Hz
2x fase+earth
5x1.5mm2
2x16A
GB
230V
~
50Hz
1 fase+earth
5x2.5mm2
25A