background image

 110406_ABI-EV1012_QSG_ML.doc 

English  

   Page 

N.V.

 abitana 

S.A.

 

ENGLISH

 

 

8. 

Turn on the power 

9. 

On the side of the Amplifier, a blue power adjustment screw 
is available. Set it to the maximum position by gently rotating 
the screw clockwise until it blocks. 

10. Remove all termination plugs and patch cords of the 

amplifier ABI-EV1012S00. 

11.  Insert the level tester ABI-TT1003S12 into port 1. 

12.  Please follow the instructions of the ABI-TT1003S12 to 

adjust the power of the amplifier correctly.  

13.  Remove the power level tester and eventually reinsert the 

previously removed termination plugs and patch cords. 

14.  Close the ‘Comm Center Cabinet’. 

15.  Locate the Outlet near your TV-set you want to connect 

16.  Take a TV/Video Balun (ABI-AC100XS00

*

), and set the level 

to maximum by means of the power level adjustment screw 
located on the balun (Turn the screw gently clockwise until it 
blocks). Then insert the Balun into the free Outlet. 

17.  Insert one end of a coax patch cord (ABI-PC1006Sxx) into 

the Balun (ABI-AC100XS00*) 

18.  Insert the other end of the Coax patch cord into the TV–set 

or VCR 

19.  In the ‘Comm Center Cabinet’, locate the Comm Center 

Connector that corresponds to the outlet where you just 
inserted the Patch cord and insert one end of a ‘Comm 
Center’ Patch cord’ of a suitable length into this connector. 

20.  Insert the other end of the Patch cord in one of the 

numbered ports (P1–P4) on the front of the Amplifier. 

21.  Check the signal quality on the TV set; and adjust the level 

by means of the level adjustment screw on the Balun if 
necessary. Normally this is only required for short links 
between the Comm center Cabinet and the outlet. 

*ABI-AC1001S00, ABI-AC1002S00 or ABI-AC1007S00 

 

IMPORTANT REMARK: 

Insert a Termination Plug (ABI-AP1003S00) in every unused 
port of the amplifier. 

If all four ports are connected to outlets, but not all outlets 
have a device (TV/VCR/…) connected to it, it is strongly 
recommended to insert a Termination Plug (ABI-AP1003S00) 
into the latter (unused) outlets. 

It is possible to use the ABI-AC100XS00

*

 Balun as a 

Termination plug, by adjusting the Power Level Screw to its 
minimum (Turn the Adjustment screw gently counter-
clockwise until it blocks), and insert the ABI-AC1001S00 into 
the unused ports or outlets. 

For IR functionality, the ABI-AC1007S00 Balun is required 

 

Additional, and more detailed information concerning this product can 
be found on the website: www.abitana.com . 

Use the following table to write down information about the amplifier 
and the connections. 

 

Amplifier Serial # 

                                                        . 

Connection to  

Coax 

P1 

P2 

P3 

P4 

 

Antenna 

…

   Cable TV 

…

 

[                                                        ] 

[                                                        ] 

[                                                        ] 

[                                                        ] 

 

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 1:  Installation on DIN-rail 

 

 

Recommendation regarding overvoltage protection 

It is recommended to add an overvoltage protection to the incoming 
signals. This protects the system against overvoltages caused by 
power surges, lightning, etc. 

A different type of protector is required for every type of signal 
(Antenna/Cable TV (5) , Telephone (6) , Mains Power (7)) 

 

EV1002

ET100X

Power

Supply

DIN-Rail

Frame

PE1002

1

2

3

4

CATV

Antenna

PSTN /ISDN

Power

220V/240V

OVP

RF

OVP

TEL

OVP

POW

5

6

7

DC1015

 

 

 

Отзывы: