background image

 

   

Table 1: Default setting Gewa Link channels 

Table 1 shows the channels and codes for Control Medi Standard on delivery. 

GewaLink channels position 

Button on 

Control Medi

 

Standard 

Level 

1-4

  

(red indicator) 

 

1

 

 

16 

22 

28 

34 

 

2

 

 

17 

23 

29 

35 

 

3

 

 

18 

24 

30 

36 

 

4

 

 

19 

25 

31 

37 

 

5

 

 

20 

26 

32 

38 

 

6

 

 

21 

27 

33 

39 

 

!

 

 

2

 

code  code  code  code 

 

---

 

 

1

 

22 

28 

34 

16 

1

 If only one level is open the 

Level

 button automatically becomes one channel. It is the first channel on the 

next level. 

Same code on all levels. 

 

NOTE:

 The table above shows GewaLink channels on delivery. It is possible to select another set of 

GewaLink channels, see section Setting the channel

 range

. 

 
 

 

Содержание Control Medi Standard

Страница 1: ...Control Medi Standard Manual Art Nr 429220 1 SE EN 4 0...

Страница 2: ......

Страница 3: ...p inst llningsl s 13 3 5 ppna st nga en niv 13 3 6 Inl rning av IR kanaler fr n en annan s ndare 14 3 7 L gga in GewaLink kanal 15 3 8 L gga in 4096 kod 15 3 9 Kopiera knapp 17 3 10 terkoppling vid kn...

Страница 4: ...Settings Lock 35 3 5 Opening Closing a Level 35 3 6 Recording IR Channels from another Transmitter 36 3 7 Adding a GewaLink channel 37 3 8 Adding a 4096 code 37 3 9 Copying a button 39 3 10 Feedback...

Страница 5: ...11 Summary and Quick guide 49...

Страница 6: ...t som kan direktstyra en knapp p s ndaren N r man trycker p en knapp s ges bekr ftelse i form av vibration ljud och ljus Control Medi r en del av GewaLink systemet och kan d rf r anv ndas tillsammans...

Страница 7: ...knapp i ca 2sekunder Olika Funktions knappar v ljs beroende av vad som ska programmeras Om man ngrar en knapptryckning eller om n got blir fel vid programmeringen kan man alltid trycka p Niv knappen i...

Страница 8: ...dtryckta i ca 2 sekunder 1 5 S tta i batterier Lossa skruvarna till batteriluckan p baksidan av Control Medi med en skruvmejsel och s tt in 3 st alkaline batterier typ LR03 AAA 1 5 V Placera batterier...

Страница 9: ...se anses allvarlig om den direkt eller indirekt ledde kan ha lett eller kan leda till n gon av dessa situationer D dsfall av anv ndare eller annan person Vid tillf llig eller permanenta allvarliga f r...

Страница 10: ......

Страница 11: ...ignaler vid programmering Vid programmering ger Control Medi terkoppling med blinkningar och olika signaler Signal Inst llning tre stegrande toner Signal Succ tre positiva toner Signal Fel tta negativ...

Страница 12: ...s r tt 1 2 3 4 1 16 22 28 34 2 17 23 29 35 3 18 24 30 36 4 19 25 31 37 5 20 26 32 38 6 21 27 33 39 2 kod kod kod kod 1 22 28 34 16 1 Om endast en niv r ppen blir Niv knappen automatiskt en kanal Det r...

Страница 13: ...3 5 ppna st nga en niv Control Medi har fyra olika niv er vilket inneb r att varje knapp kan ha fyra olika funktioner Det g r att v lja vilka niv er som ska vara ppna och d rigenom hur m nga funktione...

Страница 14: ...nar och en ljudsignal Sl pp ljuder Det kan ta upp till 10 sekunder Om lampan p vald knapp ter lyser med fast sken och ljudsignal Tryck ljuder trycker man ytterligare en eller flera g nger tills signal...

Страница 15: ...Kanalgrupp 4 Kanalgrupp 5 Kanalgrupp 6 Kanalgrupp Kanalgrupp 1 00 08 16 24 32 40 48 56 2 01 09 17 25 33 41 49 57 3 02 10 18 26 34 42 50 58 4 03 11 19 27 35 43 51 59 5 04 12 20 28 36 44 52 60 6 05 13 2...

Страница 16: ...rna 1 4 6 och 12 st r i On l ge och vriga st r i Off l ge 1 2 3 4 5 6 7 8 9 10 11 12 2048 1024 512 256 128 64 32 16 8 4 2 1 On Off Fig 3 F ljande exempel beskriver hur den bin ra koden skapas enligt m...

Страница 17: ...an trycker p en knapp Man kan ven f terkoppling i form av ljudsignal och vibration Det g r att f terkoppling p alla tre s tt samtidigt eller v lja vilka som ska vara p av ljus r alltid p G r enligt f...

Страница 18: ...el St lla in anslagsf rdr jning 2 2 sek 2 v lj inst llning 1 0 sek 2 0 3 sek 3 0 6 sek 4 1 sek Grundinst llning Anslagsf rdr jning AV 0 sek 3 12 Repetera senaste funktion I Control Medi Standard kan h...

Страница 19: ...n s ndning av en sekvens genom att trycka p annan valfri knapp N r en sekvens l rs in s nder Control Medi samtidigt det som finns p knappen Maximalt 50 knapptryckningar per sekvens g r att l ra in OBS...

Страница 20: ...2 blinkar 2 Tryck p 3 3a Aktivera direktstyrning Tryck p 2 och tryck p den knapp X som ska aktiveras vid tryck p man verkontakten eller 3b Aktivera direktstyrning av tv knappar Tryck p 3 och tryck p d...

Страница 21: ...6 61 80 85 104 109 Niv 2 06 11 22 27 38 43 621 67 86 91 110 115 Niv 3 12 17 28 33 44 49 68 73 92 97 116 121 Niv 4 18 23 34 39 50 55 74 79 98 103 122 127 1 Kanal 62 r en stoppkod och kan inte styra n g...

Страница 22: ...l Medi Denna h llare kan i sin tur monteras ihop med en bordstving r rtving f r montering p bord eller f r fasts ttning p r r H llaren g r ocks att montera p ett rullbart golvstativ Ytterligare ett al...

Страница 23: ...ndinst llning Se Tabell 1 Grundinst llning GewaLink kanaler vilka kanaler som f s vid terst llning vriga inst llningar terg r ocks till grundinst llning se ovan Om inst llningsl set r aktiverat m ste...

Страница 24: ...mif tter Vikt inkl batterier 105 gram Temperaturomr de exkl batterier 20 C 45 C 9 2 Tillbeh r som medf ljer Control Medi Standard Art nr Ben mning Beskrivning Antal 429255 Control Medi Labelling 8 M r...

Страница 25: ...ering 10 1F rvaring Produkten ska f rvaras inomhus i rumstemperatur och skyddad fr n fukt 10 2Kassering Control Medi inneh ller elektronik som ska tervinnas efter produktens livsl ngd L mnas till milj...

Страница 26: ...lj niv med v lj knapp X v lj knapp Y g vidare eller avsluta 2 sek L gga in 4096 kod 1 2 sek 2 2 v lj niv med v lj knapp X tryck 1 eller 2 12 ggr 1 Off l ge 2 On l ge Grundinst llning Slumpvis kod Kopi...

Страница 27: ...era direktstyrning 2 2 sek 3 2 v lj knapp X Aktivera direktstyrning av tv knappar 2 2 sek 3 3 v lj f rsta knapp X v lj andra knapp X V lj tid 1 4 1 2 sek 2 4 sek 3 6 sek 4 8 sek Avaktivera direktstyrn...

Страница 28: ......

Страница 29: ...directly control one button on the transmitter When you press a button confirmation is given as vibration sound and light The Control Medi is a part of the GewaLink system and therefore can be used t...

Страница 30: ...ttons for 2 seconds Different Function buttons are chosen depending on what is to be programmed If you press the wrong button or make a mistake when programming you can always press the Level button f...

Страница 31: ...held pressed for approximately 2 seconds 1 5 Inserting Batteries Unscrew the battery lid screws on the back of your Control Medi using a screwdriver and insert three AAA batteries alkaline LR03 1 5 V...

Страница 32: ...hority of your country An incident is regarded serious if it directly or indirectly led might have led or might lead to either of these situations The death of a patient user or other person The tempo...

Страница 33: ...hilst you are programming your Control Medi gives feedback with flashes and different alerts Setting three increasing tones Success three positive tones Error eight negative tones 3 2 Cancel Programmi...

Страница 34: ...22 28 34 2 17 23 29 35 3 18 24 30 36 4 19 25 31 37 5 20 26 32 38 6 21 27 33 39 2 code code code code 1 22 28 34 16 1 If only one level is open the Level button automatically becomes one channel It is...

Страница 35: ...l Your Control Medi has four different levels which means that each button can have four different functions You can select the number of levels that are open and hence how many functions each button...

Страница 36: ...selected button goes off and the Release alert sounds This may take up to 10 seconds If the indicator light glows again and the Press alert sounds you should press the button one or more times until t...

Страница 37: ...group 2 Ch group 3 Ch group 4 Ch group 5 Ch group 6 Ch group Ch group 1 00 08 16 24 32 40 48 56 2 01 09 17 25 33 41 49 57 3 02 10 18 26 34 42 50 58 4 03 11 19 27 35 43 51 59 5 04 12 20 28 36 44 52 60...

Страница 38: ...0 11 12 2048 1024 512 256 128 64 32 16 8 4 2 1 On Off Fig 3 The following example describes how the binary code is created according to method two 1 First press and then simultaneously press 1 for 2 s...

Страница 39: ...rm of light signals when you press a button You can also get feedback as sound alerts and vibration It is possible to get feedback from all three ways simultaneously or you can set up what will be on...

Страница 40: ...ss 2 2 sec 2 then choose the setting 1 0 sec 2 0 3 sec 3 0 6 sec 4 1 sec Default setting Acceptance delay OFF 0 sec 3 12 Repeating the last function Your Control Medi Standard can have a button that r...

Страница 41: ...sequence is programmed your Control Medi transmits at the same time what is already on the key A maximum of 50 button presses per sequence can be programmed NOTE The button used for the sequence must...

Страница 42: ...ntrol Press 2 and then press the button X that you want to be activated when pressing the control switch or 3b Activate direct control of two buttons Press 3 and then press the first button X that you...

Страница 43: ...80 85 104 109 Level 2 06 11 22 27 38 43 621 67 86 91 110 115 Level 3 12 17 28 33 44 49 68 73 92 97 116 121 Level 4 18 23 34 39 50 55 74 79 98 103 122 127 1 Channel 62 is a stop code and cannot contro...

Страница 44: ...our Control Medi can lie still on flat surfaces Your Control Medi can also be equipped with a clip accessory which can be attached to a belt or pocket As an optional accessory there is also a holder t...

Страница 45: ...can be used to reinstall the settings and recordings onto your transmitter Use the Control Tool USB Interface accessory sold separately The software can be downloaded www abilia com 7 Cleaning Your Co...

Страница 46: ...above If the settings lock is activated the device must first be unlocked See Locking Unlocking the Settings Lock Do the following to restore First press and then simultaneously press 3 for 2 seconds...

Страница 47: ...rubber feet Weight incl batteries 105g Operating temperature excl batteries 20 C to 45 C 9 2 Accessories included with your Control Medi Standard Art no Name Description Qty 429255 Control Medi Label...

Страница 48: ...sal 10 1Storage Keep the product indoors at room temperature and away from moist 10 2Disposal The Control Medi contains electronics components that must be recycled Dispose the product at an applicabl...

Страница 49: ...tton X select button Y then continue or finish with 2 sec Adding the 4096 code Press 1 2 sec 2 2 choose the level with choose the button X then press 1 or 2 12 times 1 Off position 2 On position Defau...

Страница 50: ...ct control Press 2 2 sec 3 2 choose the button X Activate direct control of two buttons 2 2 sec 3 3 choose the first button X choose the second button X Select time 1 4 1 2 sec 2 4 sec 3 6 sec 4 8 sec...

Страница 51: ...se Norway Abilia AS Tevlingveien 23 1081 Oslo Norway Phone 47 23 28 94 00 support abilia no www abilia no United Kingdom Abilia UK Ltd Unit12 Buckingway Business Park Swavesey Cambridge CB24 4AE Unite...

Страница 52: ...Abilia AB R sundav gen 6 Solna Sweden Phone 46 0 8 594 694 00 info abilia se www abilia se 429220 1_Manual_Control Medi Standard_SE EN March 2021...

Отзывы: