9.1 Inspection intervals
Check the following:
NOTICE
• The specified maintenance intervals are guidance values and refer to single-shift operation.
• We recommend recording the inspections. The date of the inspection, the detected defects and the
name of the inspector must be recorded.
Every day by the user
Every month by qualified personnel
Every year by qualified
personnel
Visual inspection:
Fume extraction system or parts of system
damaged?
Visual inspection:
Filter untight? (trails of dust or deposits on the air
outlets)
Visual inspection:
Dust in the turbine area, remove dust
using an industrial vacuum cleaner or a
damp disposable cloth.
Visual inspection:
Cable connections damaged?
Visual inspection:
Function of the minimum air volume flow control
guaranteed?
Seal the air inlet. As soon as the value on the
manometer indicator increases, an acoustic
signal sounds.
Visual inspection of the filter cartridge
Filling level of the dust collecting drawer
5.1 Emptying the dust collecting
drawer on page EN-13
Check the tightness
Measure the volume flow
Measure the vacuum
Measure the current consumption
Tab. 7
Inspection intervals
Содержание FES-200 W3
Страница 4: ...DE 4 1 Identifikation FES 200 W3 ...
Страница 5: ...FES 200 W3 1 Identifikation DE 5 ...
Страница 34: ...EN 4 1 Identification FES 200 W3 ...
Страница 35: ...FES 200 W3 1 Identification EN 5 ...
Страница 64: ...FR 4 1 Identification FES 200 W3 ...
Страница 65: ...FES 200 W3 1 Identification FR 5 ...
Страница 94: ...ES 4 1 Identificación FES 200 W3 ...
Страница 95: ...FES 200 W3 1 Identificación ES 5 ...
Страница 122: ...ES 32 Notas FES 200 W3 Notas ...
Страница 123: ...FES 200 W3 Notas ES 33 ...