FES-200 W3
6 Putting into operation
EN - 19
6.2 Start-stop pliers
The start-stop pliers allows you to switch on automatically the FES-200 when the welding process starts.
Mounting the start-stop pliers:
1
Connect the connector to the FES-200 W3.
2
around the cable assembly of the welding fume extraction torch.
3
to the Auto position.
The FES-200 W3 starts automatically when the welding process is started.
4
Switch off the fume extraction system by turning the rocker switch
.
• Manual = continuous operation
• 0 = off
• Auto = start-stop pliers are active (fume extraction system runs only during the welding process, and
keeps running for the set time of approx. 1 minute).
1
Manometer
2
Rocker switch (Manual-0-Auto)
3
Start-stop pliers, 4-pole (may differ from shown)
Fig. 8
Start-stop pliers
1
2
3
NOTICE
• Switch on the automatic function to increase the service life of the fume extraction system.
• When an increased smoke concentration is detected in the working area:
• Stop the welding process.
• A function check is required before putting into operation.